SearcharxivSearch

arXiv subjects

Yulia V. Gurevich

Publications and source records attributed to Yulia V. Gurevich.

8 recordsLinked to original sources

Rubidium transitions as wavelength reference for astronomical Doppler spectrographs

Precise wavelength calibration is a critical issue for high-resolution spectroscopic observations. The ideal calibration source should be able to provide a very stable and dense grid of evenly distributed spectral lines of constant intensity. A new method which satisfies all mentioned conditions has been developed by our group. The approach is to actively measure the exact position of a single spectral line of a Fabry-Perot etalon with very high precision with a wavelength-tuneable laser and compare it to an extremely stable wavelength standard. The ideal choice of standard is the D2 absorption line of Rubidium, which has been used as an optical frequency standard for decades. With this technique, the problem of stable wavelength calibration of spectrographs becomes a problem of how reliably we can measure and anchor one etalon line to the Rb transition. In this work we present our self-built module for Rb saturated absorption spectroscopy and discuss its stability.

astro-ph.IM

Methods, Analysis, and the Treatment of Systematic Errors for the Electron Electric Dipole Moment Search in Thorium Monoxide

We recently set a new limit on the electric dipole moment of the electron (eEDM) (J. Baron et al., ACME collaboration, Science 343 (2014), 269-272), which represented an order-of-magnitude improvement on the previous limit and placed more stringent constraints on many CP-violating extensions to the Standard Model. In this paper we discuss the measurement in detail. The experimental method and associated apparatus are described, together with the techniques used to isolate the eEDM signal. In particular, we detail the way experimental switches were used to suppress effects that can mimic the signal of interest. The methods used to search for systematic errors, and models explaining observed systematic errors, are also described. We briefly discuss possible improvements to the experiment.

physics.atom-ph

Stabilizing a Fabry-Perot etalon to 3 cm/s for spectrograph calibration

We present a method of frequency stabilizing a broadband etalon that can serve as a high-precision wavelength calibrator for an Echelle spectrograph. Using a laser to probe the Doppler-free saturated absorption of the rubidium D2 line, we stabilize one etalon transmission peak directly to the rubidium frequency. The rubidium transition is an established frequency standard and has been used to lock lasers to fractional stabilities of $<10^{-12}$, a level of accuracy far exceeding the demands of radial velocity (RV) searches for exoplanets. We describe a simple setup designed specifically for use at an observatory and demonstrate that we can stabilize the etalon peak to a relative precision of $<10^{-10}$; this is equivalent to 3 cm/s RV precision.

astro-ph.IM

Order of Magnitude Smaller Limit on the Electric Dipole Moment of the Electron

The Standard Model (SM) of particle physics fails to explain dark matter and why matter survived annihilation with antimatter following the Big Bang. Extensions to the SM, such as weak-scale Supersymmetry, may explain one or both of these phenomena by positing the existence of new particles and interactions that are asymmetric under time-reversal (T). These theories nearly always predict a small, yet potentially measurable ($10^{-27}$-$10^{-30}$ $e$ cm) electron electric dipole moment (EDM, $d_e$), which is an asymmetric charge distribution along the spin ($\vec{S}$). The EDM is also asymmetric under T. Using the polar molecule thorium monoxide (ThO), we measure $d_e = (-2.1 \pm 3.7_\mathrm{stat} \pm 2.5_\mathrm{syst})\times 10^{-29}$ $e$ cm. This corresponds to an upper limit of $|d_e| < 8.7\times 10^{-29}$ $e$ cm with 90 percent confidence, an order of magnitude improvement in sensitivity compared to the previous best limits. Our result constrains T-violating physics at the TeV energy scale.

physics.atom-ph

Advanced Cold Molecule Electron EDM

Measurement of a non-zero electric dipole moment (EDM) of the electron within a few orders of magnitude of the current best limit of |d_e| < 1.05 e -27 e cm would be an indication of physics beyond the Standard Model. The ACME Collaboration is searching for an electron EDM by performing a precision measurement of electron spin precession in the metastable H state of thorium monoxide (ThO) using a slow, cryogenic beam. We discuss the current status of the experiment. Based on a data set acquired from 14 hours of running time over a period of 2 days, we have achieved a 1-sigma statistical uncertainty of 1 e -28 e cm/T^(1/2), where T is the running time in days.

physics.atom-ph

Magnetic and electric dipole moments of the $H\ {}^3Δ_1$ state in ThO

The metastable $H \ {}^3Δ_1$ state in the thorium monoxide (ThO) molecule is highly sensitive to the presence of a CP-violating permanent electric dipole moment of the electron (eEDM). The magnetic dipole moment $μ_H$ and the molecule-fixed electric dipole moment $D_H$ of this state are measured in preparation for a search for the eEDM. The small magnetic moment $μ_H = 8.5(5) \times 10^{-3} \ μ_B$ displays the predicted cancellation of spin and orbital contributions in a ${}^3 Δ_1$ paramagnetic molecular state, providing a significant advantage for the suppression of magnetic field noise and related systematic effects in the eEDM search. In addition, the induced electric dipole moment is shown to be fully saturated in very modest electric fields ($<$ 10 V/cm). This feature is favorable for the suppression of many other potential systematic errors in the ThO eEDM search experiment.

physics.atom-ph

A cryogenic beam of refractory, chemically reactive molecules with expansion cooling

Cryogenically cooled buffer gas beam sources of the molecule thorium monoxide (ThO) are optimized and characterized. Both helium and neon buffer gas sources are shown to produce ThO beams with high flux, low divergence, low forward velocity, and cold internal temperature for a variety of stagnation densities and nozzle diameters. The beam operates with a buffer gas stagnation density of ~10^15-10^16 cm^-3 (Reynolds number ~1-100), resulting in expansion cooling of the internal temperature of the ThO to as low as 2 K. For the neon (helium) based source, this represents cooling by a factor of about 10 (2) from the initial nozzle temperature of about 20 K (4 K). These sources deliver ~10^11 ThO molecules in a single quantum state within a 1-3 ms long pulse at 10 Hz repetition rate. Under conditions optimized for a future precision spectroscopy application [A C Vutha et al 2010 J. Phys. B: At. Mol. Opt. Phys. 43 074007], the neon-based beam has the following characteristics: forward velocity of 170 m/s, internal temperature of 3.4 K, and brightness of 3x10^11 ground state molecules per steradian per pulse. Compared to typical supersonic sources, the relatively low stagnation density of this source, and the fact that the cooling mechanism relies only on collisions with an inert buffer gas, make it widely applicable to many atomic and molecular species, including those which are chemically reactive, such as ThO.

physics.atom-ph

Search for the electric dipole moment of the electron with thorium monoxide

The electric dipole moment of the electron (eEDM) is a signature of CP-violating physics beyond the Standard Model. We describe an ongoing experiment to measure or set improved limits to the eEDM, using a cold beam of thorium monoxide (ThO) molecules. The metastable $H {}^3Δ_1$ state in ThO has important advantages for such an experiment. We argue that the statistical uncertainty of an eEDM measurement could be improved by as much as 3 orders of magnitude compared to the current experimental limit, in a first-generation apparatus using a cold ThO beam. We describe our measurements of the $H$ state lifetime and the production of ThO molecules in a beam, which provide crucial data for the eEDM sensitivity estimate. ThO also has ideal properties for the rejection of a number of known systematic errors; these properties and their implications are described.

physics.atom-ph