SearcharxivSearch

arXiv subjects

Yuming Sun

Publications and source records attributed to Yuming Sun.

8 recordsLinked to original sources

Shao: Scaling Acoustic Token Language Models Toward High-Fidelity Music Generation

A common design pattern in high-quality music generation is to handle structure and fidelity in different representation spaces: a generator first models high-level structure, followed by diffusion-based or neural decoding stages that reconstruct fine details. In this work, we explore an alternative view: both may be progressively modeled within a single deep acoustic-token hierarchy. To study this, we build a 64-layer residual vector quantization (RVQ) acoustic representation and propose a two-stage coarse-to-fine generation framework. A backbone model first generates coarse acoustic tokens for the full track, and a super-resolution model then completes finer tokens within the same acoustic token space. The super-resolution stage works at full-track scale and refines tokens layer by layer while running in parallel over time, leading to a fixed 62-step inference process. To jointly improve lyric alignment and fine-detail reconstruction, we further introduce hybrid-attention training: the alignment objective uses causal attention, while layer-wise refinement uses full attention. A key finding is that text-vocal alignment can emerge within pure acoustic-token language modeling, without requiring a separate semantic token stage. Moreover, initializing the super-resolution model from the trained backbone significantly improves convergence and final quality. Taken together, our results suggest that high-quality music generation can be effectively pursued without separating structure and fidelity into heterogeneous representation spaces. Instead, both can be progressively modeled within a unified acoustic-token hierarchy, pointing toward a simpler and more unified path to high-quality music generation.

cs.SD

Estimating heterogeneous treatment effects with survival outcomes via a deep survival learner

Estimating heterogeneous treatment effects in survival settings is complicated by right censoring as well as the time-varying nature of the estimand. While the conditional average treatment effect (CATE) provides a natural target, most existing approaches focus on a single prespecified time point and do not account for the temporal trajectory, leading to instability in estimation. We propose a deep survival learner (DSL) for estimating heterogeneous treatment effects with right-censored outcomes. The method is based on a doubly robust pseudo-outcome whose conditional expectation identifies time-specific CATEs under standard assumptions. This construction remains unbiased if either the outcome model or the treatment assignment model is correctly specified, when properly accounting for censoring. To estimate CATEs over a clinically relevant time spectrum, DSL employs a multi-output deep neural network with shared representations, enabling joint estimation of treatment effect trajectories. From a theoretical perspective, we derive error bounds for both pointwise and joint estimation over time. We show that joint estimation can leverage temporal structure to control estimation error without incurring much additional approximation cost under smoothness conditions, leading to improved stability relative to separate estimation. Cross-fitting is incorporated to reduce overfitting and mitigate bias arising from flexible nuisance estimation. Simulation studies demonstrate favorable finite-sample performance, particularly under nuisance model misspecification. Applied to the Boston Lung Cancer Study, DSL reveals heterogeneity in the effects of perioperative chemotherapy across patient characteristics and over time.

stat.ME

Modular, On-Site Solutions with Lightweight Anomaly Detection for Sustainable Nutrient Management in Agriculture

Efficient nutrient management is critical for crop growth and sustainable resource consumption (e.g., nitrogen, energy). Current approaches require lengthy analyses, preventing real-time optimization; similarly, imaging facilitates rapid phenotyping but can be computationally intensive, preventing deployment under resource constraints. This study proposes a flexible, tiered pipeline for anomaly detection and status estimation (fresh weight, dry mass, and tissue nutrients), including a comprehensive energy analysis of approaches that span the efficiency-accuracy spectrum. Using a nutrient depletion experiment with three treatments (T1-100%, T2-50%, and T3-25% fertilizer strength) and multispectral imaging (MSI), we developed a hierarchical pipeline using an autoencoder (AE) for early warning. Further, we compared two status estimation modules of different complexity for more detailed analysis: vegetation index (VI) features with machine learning (Random Forest, RF) and raw whole-image deep learning (Vision Transformer, ViT). Results demonstrated high-efficiency anomaly detection (73% net detection of T3 samples 9 days after transplanting) at substantially lower energy than embodied energy in wasted nitrogen. The state estimation modules show trade-offs, with ViT outperforming RF on phosphorus and calcium estimation (R2 0.61 vs. 0.58, 0.48 vs. 0.35) at higher energy cost. With our modular pipeline, this work opens opportunities for edge diagnostics and practical opportunities for agricultural sustainability.

cs.CV

IMUVIE: Pickup Timeline Action Localization via Motion Movies

Falls among seniors due to difficulties with tasks such as picking up objects pose significant health and safety risks, impacting quality of life and independence. Reliable, accessible assessment tools are critical for early intervention but often require costly clinic-based equipment and trained personnel, limiting their use in daily life. Existing wearable-based pickup measurement solutions address some needs but face limitations in generalizability. We present IMUVIE, a wearable system that uses motion movies and a machine-learning model to automatically detect and measure pickup events, providing a practical solution for frequent monitoring. IMUVIE's design principles-data normalization, occlusion handling, and streamlined visuals-enhance model performance and are adaptable to tasks beyond pickup classification. In rigorous leave one subject out cross validation evaluations, IMUVIE achieves exceptional window level localization accuracy of 91-92% for pickup action classification on 256,291 motion movie frame candidates while maintaining an event level recall of 97% when evaluated on 129 pickup events. IMUVIE has strong generalization and performs well on unseen subjects. In an interview survey, IMUVIE demonstrated strong user interest and trust, with ease of use identified as the most critical factor for adoption. IMUVIE offers a practical, at-home solution for fall risk assessment, facilitating early detection of movement deterioration, and supporting safer, independent living for seniors.

cs.LG

Penalized Deep Partially Linear Cox Models with Application to CT Scans of Lung Cancer Patients

Lung cancer is a leading cause of cancer mortality globally, highlighting the importance of understanding its mortality risks to design effective patient-centered therapies. The National Lung Screening Trial (NLST) employed computed tomography texture analysis, which provides objective measurements of texture patterns on CT scans, to quantify the mortality risks of lung cancer patients. Partially linear Cox models have gained popularity for survival analysis by dissecting the hazard function into parametric and nonparametric components, allowing for the effective incorporation of both well-established risk factors (such as age and clinical variables) and emerging risk factors (e.g., image features) within a unified framework. However, when the dimension of parametric components exceeds the sample size, the task of model fitting becomes formidable, while nonparametric modeling grapples with the curse of dimensionality. We propose a novel Penalized Deep Partially Linear Cox Model (Penalized DPLC), which incorporates the SCAD penalty to select important texture features and employs a deep neural network to estimate the nonparametric component of the model. We prove the convergence and asymptotic properties of the estimator and compare it to other methods through extensive simulation studies, evaluating its performance in risk prediction and feature selection. The proposed method is applied to the NLST study dataset to uncover the effects of key clinical and imaging risk factors on patients' survival. Our findings provide valuable insights into the relationship between these factors and survival outcomes.

stat.ML

Optimal free-surface pumping by an undulating carpet

Examples of fluid flows driven by undulating boundaries are found in nature across many different length scales. Even though different driving mechanisms have evolved in distinct environments, they perform essentially the same function: directional transport of liquid. Nature-inspired strategies have been adopted in engineered devices to manipulate and direct flow. Here, we demonstrate how an undulating boundary generates large-scale pumping of a thin liquid near the liquid-air interface. Two dimensional traveling waves on the undulator, a canonical strategy to transport fluid at low Reynolds numbers, surprisingly lead to flow rates that depend non-monotonically on the wave speed. Through an asymptotic analysis of the thin-film equations that account for gravity and surface tension, we predict the observed optimal speed that maximizes pumping. Our findings reveal a novel mode of pumping with less energy dissipation near a free surface compared to a rigid boundary.

physics.flu-dyn

Multi-channel quantum noise suppression and phase-sensitive modulation in a hybrid optical resonant cavity system

Quantum noise suppression and phase-sensitive modulation of continuously variable in vacuum and squeezed fields in a hybrid resonant cavity system are investigated theoretically. Multiple dark windows similar to electromagnetic induction transparency (EIT) are observed in quantum noise fluctuation curve. The effects of pumping light on both suppression of quantum noise and control the widths of dark windows are carefully analyzed, and the saturation point of pumping light for nonlinear crystal conversion is obtained. We find that the noise suppression effect is strongly sensitive to the pumping light power. The degree of noise suppression can be up to 13.9 dB when the pumping light power is 6.5 Beta_th. Moreover, a phase-sensitive modulation scheme is demonstrated, which well fills the gap that multi-channel quantum noise suppression is difficult to realize at the quadrature amplitude of squeezed field. Our result is meaningful for various applications in precise measurement physics, quantum information processing and quantum communications of system-on-a-chip.

quant-ph

Individualized Risk Assessment of Preoperative Opioid Use by Interpretable Neural Network Regression

Preoperative opioid use has been reported to be associated with higher preoperative opioid demand, worse postoperative outcomes, and increased postoperative healthcare utilization and expenditures. Understanding the risk of preoperative opioid use helps establish patient-centered pain management. In the field of machine learning, deep neural network (DNN) has emerged as a powerful means for risk assessment because of its superb prediction power; however, the blackbox algorithms may make the results less interpretable than statistical models. Bridging the gap between the statistical and machine learning fields, we propose a novel Interpretable Neural Network Regression (INNER), which combines the strengths of statistical and DNN models. We use the proposed INNER to conduct individualized risk assessment of preoperative opioid use. Intensive simulations and an analysis of 34,186 patients expecting surgery in the Analgesic Outcomes Study (AOS) show that the proposed INNER not only can accurately predict the preoperative opioid use using preoperative characteristics as DNN, but also can estimate the patient specific odds of opioid use without pain and the odds ratio of opioid use for a unit increase in the reported overall body pain, leading to more straightforward interpretations of the tendency to use opioids than DNN. Our results identify the patient characteristics that are strongly associated with opioid use and is largely consistent with the previous findings, providing evidence that INNER is a useful tool for individualized risk assessment of preoperative opioid use.

cs.LG