SearcharxivSearch

arXiv subjects

Yunxin Tang

Publications and source records attributed to Yunxin Tang.

3 recordsLinked to original sources

Low-cost algorithm-to-execution framework for surface-code quantum computing

The execution of useful quantum algorithms on fault-tolerant processors requires more than a mapping from logical gates to encoded operations: the spatial organization, non-Clifford resource supply, and execution schedule must also be determined while keeping physical overhead within practical limits. Although the theoretical hierarchy from logical circuits to fault-tolerant operations is well established, these implementation choices are often specified and optimized separately. Here we develop a low-cost algorithm-to-execution framework for surface-code quantum computing. From hierarchical algorithm descriptions, it constructs dependency-preserving logical schedules and an executable workload capturing logical interactions, operation parallelism, and time-resolved non-Clifford demand, thereby linking logical computation to surface-code organization, resource-state preparation, and fault-tolerant execution in a traceable workflow. We apply the framework to twenty benchmark circuits across seven algorithm families and a hierarchically composed application-scale elliptic-curve discrete-logarithm workload. Physical costs vary substantially even for circuits with similar logical resource counts. Under our direct-rotation calibration, non-Clifford implementation selection reduces space-time volume by up to 241.5 times versus an all-synthesis baseline for the QAOA amplitude-amplification workload. Circuit-specific surface-code layouts reduce routed-latency estimates for all twenty benchmarks; thirteen also reduce space-time volume because communication savings outweigh added spatial overhead. These results show that low-cost fault-tolerant execution depends on computation scheduling and organization, not aggregate logical resource counts alone.

quant-ph

Estimating Local Observables via Cluster-Level Light-Cone Decomposition

Simulating large quantum circuits on hardware with limited qubit counts is often attempted through methods like circuit knitting, which typically incur sample costs that grow exponentially with the number of connections cut. In this work, we introduce a framework based on Cluster-level Light-cone analysis that leverages the natural locality of quantum workloads. We propose two complementary algorithms: the Causal Decoupling Algorithm, which exploits geometric disconnections in the light cone for sampling efficiency, and the Algebraic Decomposition Algorithm, which utilizes algebraic expansion to minimize hardware requirements. These methods allow simulation costs to depend on circuit depth and connectivity rather than system size. Together, our results generalize Lieb-Robinson-inspired locality to modular architectures and establish a quantitative framework for probing local physics on near-term quantum devices by decoupling the simulation cost from the global system size.

quant-ph

Breast tumor classification based on self-supervised contrastive learning from ultrasound videos

Background: Breast ultrasound is prominently used in diagnosing breast tumors. At present, many automatic systems based on deep learning have been developed to help radiologists in diagnosis. However, training such systems remains challenging because they are usually data-hungry and demand amounts of labeled data, which need professional knowledge and are expensive. Methods: We adopted a triplet network and a self-supervised contrastive learning technique to learn representations from unlabeled breast ultrasound video clips. We further designed a new hard triplet loss to to learn representations that particularly discriminate positive and negative image pairs that are hard to recognize. We also constructed a pretraining dataset from breast ultrasound videos (1,360 videos from 200 patients), which includes an anchor sample dataset with 11,805 images, a positive sample dataset with 188,880 images, and a negative sample dataset dynamically generated from video clips. Further, we constructed a finetuning dataset, including 400 images from 66 patients. We transferred the pretrained network to a downstream benign/malignant classification task and compared the performance with other state-of-the-art models, including three models pretrained on ImageNet and a previous contrastive learning model retrained on our datasets. Results and conclusion: Experiments revealed that our model achieved an area under the receiver operating characteristic curve (AUC) of 0.952, which is significantly higher than the others. Further, we assessed the dependence of our pretrained model on the number of labeled data and revealed that <100 samples were required to achieve an AUC of 0.901. The proposed framework greatly reduces the demand for labeled data and holds potential for use in automatic breast ultrasound image diagnosis.

cs.CV