SearcharxivSearch

arXiv subjects

Yunyun Fan

Publications and source records attributed to Yunyun Fan.

13 recordsLinked to original sources

Huizhou Hadron Spectrometer -- a Proposed High-rate Experimental Setup at the High Intensity Heavy-ion Accelerator Facility

The High-Intensity Heavy-Ion Accelerator Facility (HIAF), currently under construction in Huizhou, Guangdong Province, China, is projected to be completed by 2025. This facility will be capable of producing proton and heavy-ion beams with energies reaching several GeV, thereby offering a versatile platform for advanced fundamental physics research. Key scientific objectives include exploring physics beyond the Standard Model through the search for novel particles and interactions, testing fundamental symmetries, investigating exotic hadronic states such as di-baryons, pentaquark states and multi-strange hypernuclei, conducting precise measurements of hadron and hypernucleus properties, and probing the phase boundary and critical point of nuclear matter. To facilitate these investigations, we propose the development of a dedicated experimental apparatus at HIAF - the Huizhou Hadron Spectrometer (HHaS). This paper presents the conceptual design of HHaS, comprising a solenoid magnet, a five-dimensional silicon pixel tracker, a Low-Gain Avalanche Detector (LGAD) for time-of-flight measurements, and a Cherenkov-scintillation dual-readout electromagnetic calorimeter. The design anticipates an unprecedented event rate of 1-100 MHz, extensive particle acceptance, a track momentum resolution at 1% level, an electromagnetic energy resolution of ~3% @ 1 GeV and multi-particle identification capabilities. Such capabilities position HHaS as a powerful instrument for advancing experimental studies in particle and nuclear physics. The successful realization of HHaS is expected to significantly bolster the development of medium- and high-energy physics research within China.

hep-ex

Evaluation of PID Performance at CEPC and Optimization with Combined dN/dx and Time-of-Flight Data

Charged-hadron identification (PID) is a critical requirement for the physics program of the Circular Electron-Positron Collider (CEPC). The baseline detector relies on ionization measurements from a time projection chamber (TPC), which provides strong PID capability at low momenta but becomes less effective at higher momenta. In this work, we investigate an extended PID strategy that combines dN/dx information from the TPC with time-of-flight (ToF) measurements from a silicon-based outer tracker (OTK) and a timing-upgraded inner tracker (ITK) equipped with AC-LGAD sensors. A unified discriminant is constructed to exploit the complementary sensitivity of ionization and timing observables. The performance is evaluated using simulated $Z \to q\bar{q}$ events, focusing on kaon identification in the presence of dominant pion backgrounds. The combined configuration significantly improves both efficiency and purity over a broad kinematic range, extending PID capability to both sub-GeV and multi-GeV regions. These results highlight the impact of precision timing on tracking detectors and demonstrate a viable path to enhanced PID performance for future lepton colliders.

hep-ex

The Performance of AC-coupled Strip LGAD developed by IHEP

The AC-coupled Strip LGAD (Strip AC-LGAD) is a novel LGAD design that diminishes the density of readout electronics through the use of strip electrodes, enabling the simultaneous measurement of time and spatial information. The Institute of High Energy Physics has designed a long Strip AC-LGAD prototype with a strip electrode length of 5.7 mm and pitches of 150 $μm$, 200 $μm$, and 250 $μm$. Spatial and timing resolutions of the long Strip AC-LGAD are studied by pico-second laser test and beta source tests. The laser test demonstrates that spatial resolution improves as the pitch size decreases, with an optimal resolution achieved at 8.3 $μ$m. Furthermore, the Beta source test yields a timing resolution of 37.6 ps.

physics.ins-det

Development of the strip LGAD detector with double-end readout for future colliders

The Low-Gain Avalanche Diode (LGAD) is a new silicon detector and holds wide application prospects in particle physics experiments due to its excellent timing resolution. The LGAD with a pixel size of 1.3 mm $\times$ 1.3 mm was used to construct a High Granularity Timing Detector (HGTD) in ATLAS experiments to solve the pile-up problem. Meanwhile, the Circular Electron Positron Collider (CEPC) also proposes detectors using the LGAD. However, pixel LGAD exhibits higher readout electronics density and cost, which somewhat limits the application of LGADs. To decrease the readout electronics density, the Institute of High Energy Physics (IHEP) of the Chinese Academy of Sciences has designed strip LGADs with larger areas. These strip LGADs are all 19 mm in length but with different widths of 1.0 mm, 0.5 mm, and 0.3 mm. This article provides a detailed introduction to the design parameters of these strip LGADs and tests their electrical characteristics, including leakage current, break-down voltage, depletion capacitance, etc. The timing resolution and signal-to-noise ratio of the three strip LGAD sensors were investigated using a beta source test system. The position resolution parallel to the strip direction was tested and analyzed for the first time using a pico-second laser test system. Tests have demonstrated that the timing resolution of strip LGADs can reach about 37.5 ps, and position resolution parallel to the strip direction is better than 1 mm.

physics.ins-det

Performance of AC-LGAD strip sensor designed for the DarkSHINE experiment

AC-coupled Low Gain Avalanche Detector (AC-LGAD) is a new precise detector technology developed in recent years. Based on the standard Low Gain Avalanche Detector (LGAD) technology, AC-LGAD sensors can provide excellent timing performance and spatial resolution. This paper presents the design and performance of several prototype AC-LGAD strip sensors for the DarkSHINE tracking system, as well as the electrical characteristics and spatial resolution of the prototype sensors from two batches of wafers with different $n^+$ dose.The range of spatial resolutions of 6.5$\mathrm{μm}$ $\sim$ 8.2$\mathrm{μm}$ and 8.8$\mathrm{μm}$ $\sim$ 12.3$\mathrm{μm}$ are achieved by the AC-LGAD sensors with 100$μm$ pitch size.

physics.ins-det

The performance of large-pitch AC-LGAD with different N+ dose

AC-Coupled LGAD (AC-LGAD) is a new 4D detector developed based on the Low Gain Avalanche Diode (LGAD) technology, which can accurately measure the time and spatial information of particles. The Institute of High Energy Physics (IHEP) designed a large-size AC-LGAD with a pitch of 2000~\SI{}{\micro\metre} and AC pad of 1000~\SI{}{\micro\metre}, and explored the effect of N+ layer dose on the spatial resolution and time resolution. The spatial resolution varied from 36~\SI{}{\micro\metre} to 16~\SI{}{\micro\metre} depending on N+ dose for a charge corresponding to about 12 minimum ionizing particles. The jitter component of the time resolution does not change significantly with different N+ doses, and it is about 15-17 ps measured by laser. The AC-LGAD with a low N+ dose has a large attenuation factor and better spatial resolution in the central region between pads. In these specific conditions, large signal attenuation factor and low noise level are beneficial to improve the spatial resolution of the AC-LGAD sensor.

physics.ins-det

Characterization of the response of IHEP-IME LGAD with shallow carbon to Gamma Irradiation

Low Gain Avalanche Detectors (LGAD) for the High-Granularity Timing Detector (HGTD) are crucial in reducing pileups in the High-Luminosity Large Hadron Collider. Numerous studies have been conducted on the bulk irradiation damage of LGADs. However, few studies have been carried out on the surface irradiation damage of LGAD sensors with shallow carbon implantation. In this paper, the IHEP-IME LGADs with shallow carbon implantation were irradiated up to 2 MGy using gamma irradiation to investigate surface damage. Important characteristic parameters, including leakage currents, breakdown voltage (BV), inter-pad resistances, and capacitances, were tested before and after irradiation. The results showed that the leakage current and BV increased after irradiation, whereas overall inter-pad resistance exhibited minimal change and remained above $10^9\ Ω$ before and after irradiation. Capacitance was found to be less than 4.5 pF with a slight decrease in the gain layer depletion voltage (V$_{gl}$) after irradiation. No parameter affected by the inter-pad separation was observed before and after irradiation. All characteristic parameters meet the requirements of HGTD, and this design can be used to further optimization.

physics.ins-det

Leakage current simulations of Low Gain Avalanche Diode with improved Radiation Damage Modeling

We report precise TCAD simulations of IHEP-IME-v1 Low Gain Avalanche Diode (LGAD) calibrated by secondary ion mass spectroscopy (SIMS). Our setup allows us to evaluate the leakage current, capacitance, and breakdown voltage of LGAD, which agree with measurements' results before irradiation. And we propose an improved LGAD Radiation Damage Model (LRDM) which combines local acceptor removal with global deep energy levels. The LRDM is applied to the IHEP-IME-v1 LGAD and able to predict the leakage current well at -30 $^{\circ}$C after an irradiation fluence of $ Φ_{eq}=2.5 \times 10^{15} ~n_{eq}/cm^{2}$. The charge collection efficiency (CCE) is under development.

physics.ins-det

Design and testing of LGAD sensor with shallow carbon implantation

The low gain avalanche detectors (LGADs) are thin sensors with fast charge collection which in combination with internal gain deliver an outstanding time resolution of about 30 ps. High collision rates and consequent large particle rates crossing the detectors at the upgraded Large Hadron Collider (LHC) in 2028 will lead to radiation damage and deteriorated performance of the LGADs. The main consequence of radiation damage is loss of gain layer doping (acceptor removal) which requires an increase of bias voltage to compensate for the loss of charge collection efficiency and consequently time resolution. The Institute of High Energy Physics (IHEP), Chinese Academy of Sciences (CAS) has developed a process based on the Institute of Microelectronics (IME), CAS capability to enrich the gain layer with carbon to reduce the acceptor removal effect by radiation. After 1 MeV neutron equivalent fluence of 2.5$\times$10$^{15}$ n$_{eq}$/cm$^{2}$, which is the maximum fluence to which sensors will be exposed at ATLAS High Granularity Timing Detector (HGTD), the IHEP-IME second version (IHEP-IMEv2) 50 $μ$m LGAD sensors already deliver adequate charge collection > 4 fC and time resolution < 50 ps at voltages < 400 V. The operation voltages of these 50 $μ$m devices are well below those at which single event burnout may occur.

physics.ins-det

Low Gain Avalanche Detectors with Good Time Resolution Developed by IHEP and IME for ATLAS HGTD project

This paper shows the simulation and test results of 50um thick Low Gain Avalanche Detectors (LGAD) sensors designed by the Institute of High Energy Physics (IHEP) and fabricated by the Institute of Microelectronics of the Chinese Academy of Sciences (IME). Three wafers have been produced with four different gain layer implant doses each. Different production processes, including variation in the n++ layer implant energy and carbon co-implantation were used. Test results show that the IHEP-IME sensors with the higher dose of gain layer have lower breakdown voltages and higher gain layer voltages from capacitance-voltage properties, which are consistent with the TCAD simulation. Beta test results show that the time resolution of IHEP-IME sensors is better than 35ps when operated at high voltage and the collected charges of IHEP-IME sensors are larger than 15fC before irradiation, which fulfill the required specifications of sensors before irradiations for the ATLAS HGTD project.

physics.ins-det

Effects of shallow carbon and deep N++ layer on the radiation hardness of IHEP-IME LGAD sensors

Low Gain Avalanche Diode (LGAD) is applied for the High-Granularity Timing Detector (HGTD), and it will be used to upgrade the ATLAS experiment. The first batch IHEP-IME LGAD sensors were designed by the Institute of High Energy Physics (IHEP) and fabricated by the Institute of Microelectronics (IME). Three IHEP-IME sensors (W1, W7 and W8) were irradiated by the neutrons up to the fluence of 2.5 x 10^15 n_eq/cm^2 to study the effect of the shallow carbon and deep N++ layer on the irradiation hardness. Taking W7 as a reference, W1 has an extra shallow carbon applied, and W8 has a deeper N++ layer.

physics.ins-det

The performance of IHEP-NDL LGAD sensors after neutron irradiation

The performances of Low Gain Avalanche diode (LGAD) sensors from a neutron irradiation campaign with fluences of 0.8 x 10^15, 15 x 10^15 and 2.5 x 10^15 neq/cm2 are reported in this article. These LGAD sensors are developed by the Institute of High Energy Physics, Chinese Academy of Sciences and the Novel Device Laboratory for the High Granularity Timing Detector of the High Luminosity Large Hadron Collider. The timing resolution and collected charge of the LGAD sensors were measured with electrons from a beta source. After irradiation with a fluence of 2.5 x 10^15 neq/cm2, the collected charge decreases from 40 fC to 7 fC, the signal-to-noise ratio deteriorates from 48 to 12, and the timing resolution increases from 29 ps to 39 ps.

physics.ins-det

Charaterization of the first prototype IHEP-NDL LGAD sensor

The timing measurement of charged particles using silicon detector is widely used in synchrotron source as X-ray detectors, in time-of-flight mass spectrometer and especially in large collider experiment. To reduce the drastically event pile-up of high-luminosity large hadron collider (HL-LHC), a new concept of 4-dimension detector including timing and positon has been proposed. One of the candidates for the 4-dimension detector is a new kind of silicon detector called Low Gain Avalanche Diode (LGAD). In China, Institute of High Energy Physics (IHEP) Chinese Academic Science cooperated with Novel Device Laboratory (NDL) at Beijing Normal University have fabricated a series of LGAD sensors. The characterization of the first prototype of IHEP-NDL sensors is presented including leakage current and sensor capacitance measurement. A test system for the time resolution of jitter term using pico-second laser and fast sampling rate oscilloscope is also setup, and the time resolution of 10 ps can be achieved with these sensors.

physics.ins-det