Searcharxiv⌕ Search

arXiv subjects

Yupeng Liu

Publications and source records attributed to Yupeng Liu.

7 recordsLinked to original sources

Kosmo-GFM: A Production-Ready Geometry Foundation Model

We present Kosmo-GFM, a scene reconstruction system that integrates a geometry foundation model (GFM), a pose optimization engine (PoseEngine), and reconstruction-derived supervision from KosmoWorld. GFM predicts camera parameters, depth, cross-view correspondences, and dynamic 3D points from images and videos. PoseEngine combines these predictions with geometric optimization to recover scene-level camera poses and geometry for downstream 3D and 4D Gaussian Splatting. KosmoWorld generates images and geometric supervision from reconstructed real-world scenes to improve GFM's geometric predictions. On the Sparse and Medium subsets of SpatialBench, GFM achieves the lowest absolute relative depth error and the highest relative-pose AUC at 5 degrees among the compared methods. It also achieves the lowest mean endpoint errors for dynamic points and scene flow across the five evaluated datasets. Across 34 scenes completed by all compared reconstruction systems, PoseEngine achieves the highest scene-averaged pose AUC at thresholds of 1, 3, and 5 degrees, with a cumulative runtime of 14.07 hours, approximately 20% of GLUEMAP's 69.67 hours. PoseEngine Flash provides a further accuracy-efficiency trade-off, with a measured mixed-precision runtime of 2.62 hours, approximately 4% of GLUEMAP's runtime. Separate scaling experiments show generally favorable trends with increased data, model computation, and training budgets. These results support the use of learned geometric priors within a scene-level reconstruction pipeline.

cs.CV↗

Moving Regions, Not Moving Objects: Segmenting What Actually Moves under Camera Motion

Moving object segmentation is conventionally formulated at the sequence and object level, marking an entire instance as moving once it moves anywhere in a video. Recent instantaneous formulations distinguish moving from stationary intervals, but still generate masks at the object level through frozen segmentation foundation models. Because the mask is derived from an instance-level proposal, motion is typically attributed to the entire instance rather than localized to the regions that actually move. Moreover, such instance-level predictions can produce masks even when no part of the instance is actually moving, revealing a more fundamental issue: motion is not an intrinsic property of an instance; it can only be determined by comparing at least two frames. Building on this premise, we introduce MoRSe, which jointly interprets two frames to predict a moving-region mask, distinguishing actual scene motion from apparent motion induced by the camera. A single RGB encoder replaces multi-stage foundation stacks, so no optical flow, point tracks, or separate mask generator is needed at inference. We release MoRSe-5K, a benchmark of 42 sequences with Static, Dynamic-Static, and Dynamic settings designed to evaluate the model's ability to distinguish and localize moving and stationary regions under different camera and scene motion conditions. MoRSe outperforms both specialized moving object segmentation methods and dense 4D reconstruction methods with motion-thresholded predictions, while producing the fewest false positives on sequences where nothing moves.

cs.CV↗

DTEA: Dynamic Topology Weaving and Instability-Driven Entropic Attenuation for Medical Image Segmentation

In medical image segmentation, skip connections are used to merge global context and reduce the semantic gap between encoder and decoder. Current methods often struggle with limited structural representation and insufficient contextual modeling, affecting generalization in complex clinical scenarios. We propose the DTEA model, featuring a new skip connection framework with the Semantic Topology Reconfiguration (STR) and Entropic Perturbation Gating (EPG) modules. STR reorganizes multi-scale semantic features into a dynamic hypergraph to better model cross-resolution anatomical dependencies, enhancing structural and semantic representation. EPG assesses channel stability after perturbation and filters high-entropy channels to emphasize clinically important regions and improve spatial attention. Extensive experiments on three benchmark datasets show our framework achieves superior segmentation accuracy and better generalization across various clinical settings. The code is available at \href{https://github.com/LWX-Research/DTEA}{https://github.com/LWX-Research/DTEA}.

cs.CV↗

EEMS: Edge-Prompt Enhanced Medical Image Segmentation Based on Learnable Gating Mechanism

Medical image segmentation is vital for diagnosis, treatment planning, and disease monitoring but is challenged by complex factors like ambiguous edges and background noise. We introduce EEMS, a new model for segmentation, combining an Edge-Aware Enhancement Unit (EAEU) and a Multi-scale Prompt Generation Unit (MSPGU). EAEU enhances edge perception via multi-frequency feature extraction, accurately defining boundaries. MSPGU integrates high-level semantic and low-level spatial features using a prompt-guided approach, ensuring precise target localization. The Dual-Source Adaptive Gated Fusion Unit (DAGFU) merges edge features from EAEU with semantic features from MSPGU, enhancing segmentation accuracy and robustness. Tests on datasets like ISIC2018 confirm EEMS's superior performance and reliability as a clinical tool.

cs.CV↗

FS-RWKV: Leveraging Frequency Spatial-Aware RWKV for 3T-to-7T MRI Translation

Ultra-high-field 7T MRI offers enhanced spatial resolution and tissue contrast that enables the detection of subtle pathological changes in neurological disorders. However, the limited availability of 7T scanners restricts widespread clinical adoption due to substantial infrastructure costs and technical demands. Computational approaches for synthesizing 7T-quality images from accessible 3T acquisitions present a viable solution to this accessibility challenge. Existing CNN approaches suffer from limited spatial coverage, while Transformer models demand excessive computational overhead. RWKV architectures offer an efficient alternative for global feature modeling in medical image synthesis, combining linear computational complexity with strong long-range dependency capture. Building on this foundation, we propose Frequency Spatial-RWKV (FS-RWKV), an RWKV-based framework for 3T-to-7T MRI translation. To better address the challenges of anatomical detail preservation and global tissue contrast recovery, FS-RWKV incorporates two key modules: (1) Frequency-Spatial Omnidirectional Shift (FSO-Shift), which performs discrete wavelet decomposition followed by omnidirectional spatial shifting on the low-frequency branch to enhance global contextual representation while preserving high-frequency anatomical details; and (2) Structural Fidelity Enhancement Block (SFEB), a module that adaptively reinforces anatomical structure through frequency-aware feature fusion. Comprehensive experiments on UNC and BNU datasets demonstrate that FS-RWKV consistently outperforms existing CNN-, Transformer-, GAN-, and RWKV-based baselines across both T1w and T2w modalities, achieving superior anatomical fidelity and perceptual quality.

eess.IV↗

Chiral anomaly induced negative magnetoresistance in topological Weyl semimetal NbAs

In this paper, we report the intercone transport of Weyl fermions in NbAs with external magnetic field in parallel to electric field, a quantum phenomenon known as the Adler-Bell-Jackiw anomaly. Surprisingly, the resulting negative magnetoresistance (MR) in NbAs shows significant difference from NbP. The observed low-field positive MR dip, which is missing in NbP at low temperatures, indicates that the spin-orbital coupling (SOC) is significantly stronger in NbAs than in the former. The results imply that the contribution of arsenic to SOC in TaAs and NbAs is not negligible.

cond-mat.mtrl-sci↗

Perpendicular magnetic anisotropy of full-Heusler films in Pt/Co2FeAl/MgO trilayers

We report on perpendicular magnetic anisotropy (PMA) in a Pt/Co2FeAl/MgO sandwiched structure with a thick Co2FeAl layer of 2-2.5 nm. The PMA is thermally stable that the anisotropy energy density Ku is 1.3{\times}106 erg/cm3 for the structure with 2 nm Co2FeAl after annealing at 350 oC. The thicknesses of Co2FeAl and MgO layers greatly affect the PMA. Our results provide an effective way to realize relative thick perpendicularly magnetized Heusler alloy films.

cond-mat.mtrl-sci↗