SearcharxivSearch

arXiv subjects

Yusuke Takagi

Publications and source records attributed to Yusuke Takagi.

8 recordsLinked to original sources

Flow as Flow: Modeling Robot Velocity Fields as Probability Velocity Fields for Flow-Based Object Manipulation

Cross-embodiment data have become central to training robotic foundation models. To leverage such heterogeneous data, we focus on flow-based object manipulation, where robot flows (robot velocity fields) serve as embodiment-agnostic motion representations. Previous studies do not formulate robot flows as dense velocity fields, but as displacements of sparse keypoints, while such velocity fields better match the continuous-time nature of motions. We propose Flow as Flow, a framework that models robot flows as probability flows based on a flow matching formulation. By naturally modeling such velocity fields within this formulation, our method achieves efficient and high-quality robot flow generation. Across standard benchmarks, our method outperforms representative baseline methods on standard metrics, while achieving approximately 33$\times$ faster generation. Furthermore, through real-world experiments evaluating 9 methods with 260 trials per method across 13 manipulation tasks, we show that our method achieves a higher average success rate than the baseline methods. Our project page is available at https://flow-as-flow-u0n5y.kinsta.page.

cs.RO

AnoleVLA: Lightweight Vision-Language-Action Model with Deep State Space Models for Mobile Manipulation

In this study, we address the problem of language-guided robotic manipulation, where a robot is required to manipulate a wide range of objects based on visual observations and natural language instructions. This task is essential for service robots that operate in human environments, and requires safety, efficiency, and task-level generality. Although Vision-Language-Action models (VLAs) have demonstrated strong performance for this task, their deployment in resource-constrained environments remains challenging because of the computational cost of standard transformer backbones. To overcome this limitation, we propose AnoleVLA, a lightweight VLA that uses a deep state space model to process multimodal sequences efficiently. The model leverages its lightweight and fast sequential state modeling to process visual and textual inputs, which allows the robot to generate trajectories efficiently. We evaluated the proposed method in both simulation and physical experiments. Notably, in real-world evaluations, AnoleVLA outperformed a representative large-scale VLA by 21 points for the task success rate while achieving an inference speed approximately three times faster.

cs.RO

Self-Viscophoresis: Autonomous Motion by Biasing Thermal Fluctuations via Self-Generated Viscosity Asymmetry

Microscale transport often relies on ubiquitous yet intrinsically random thermal fluctuations. Understanding how such fluctuations can be biased into directed motion has long been a central theme of nonequilibrium physics. Here, we introduce self-viscophoresis, a mechanism of autonomous motion based on the rectification of thermal fluctuations in a self-generated nonequilibrium viscosity field. Asymmetric colloidal particles dispersed in a thermoresponsive polymer solution induce local heating under uniform illumination, producing a spatially asymmetric viscosity profile around the particle and resulting in persistent directed motion. To elucidate the physical origin of this behavior, we develop a minimal Langevin model coupling isotropic thermal fluctuations to a dynamically updating temperature-viscosity field. The model shows that viscosity asymmetry anisotropically damps stochastic dynamics, effectively biasing thermal fluctuations into a net drift. It thus reproduces the observed directed motion without invoking deterministic propulsion terms associated with effective potentials or environmental fluid flows. Our results distinguish self-viscophoresis from conventional self-propulsion mechanisms and establish it as a general framework enabling reversible control of both the direction and dimensionality of motion.

cond-mat.soft

Eye-Tracking as a Tool to Quantify the Effects of CAD Display on Radiologists' Interpretation of Chest Radiographs

Rationale and Objectives: Computer-aided detection systems for chest radiographs are widely used, and concurrent reader displays, such as bounding-box (BB) highlights, may influence the reading process. This pilot study used eye tracking to conduct a preliminary experiment to quantify which aspects of visual search were affected. Materials and Methods: We sampled 180 chest radiographs from the VinDR-CXR dataset: 120 with solitary pulmonary nodules or masses and 60 without. The BBs were configured to yield an overall display sensitivity and specificity of 80%. Three radiologists (with 11, 5, and 1 years of experience, respectively) interpreted each case twice - once with BBs visible and once without - after a washout of >= 2 weeks. Eye movements were recorded using an EyeTech VT3 Mini. Metrics included interpretation time, time to first fixation on the lesion, lesion dwell time, total gaze-path length, and lung-field coverage ratio. Outcomes were modeled using a linear mixed model, with reading condition as a fixed effect and case and reader as random intercepts. The primary analysis was restricted to true positives (n=96). Results: Concurrent BB display prolonged interpretation time by 4.9 s (p<0.001) and increased lesion dwell time by 1.3 s (p<0.001). Total gaze-path length increased by 2,076 pixels (p<0.001), and lung-field coverage ratio increased by 10.5% (p<0.001). Time to first fixation on the lesion was reduced by 1.3 s (p<0.001). Conclusion: Eye tracking captured measurable alterations in search behavior associated with concurrent BB displays during chest radiograph interpretation. These findings support the feasibility of this approach and highlight the need for larger studies to confirm effects and explore implications across modalities and clinical contexts.

eess.IV

FLARE-SSM: Deep State Space Models with Influence-Balanced Loss for 72-Hour Solar Flare Prediction

Accurate and reliable solar flare predictions are essential to mitigate potential impacts on critical infrastructure. However, the current performance of solar flare forecasting is insufficient. In this study, we address the task of predicting the class of the largest solar flare expected to occur within the next 72 hours. Existing methods often fail to adequately address the severe class imbalance across flare classes. To address this issue, we propose a solar flare prediction model based on multiple deep state space models. In addition, we introduce the frequency & local-boundary-aware reliability loss (FLARE loss) to improve predictive performance and reliability under class imbalance. Experiments were conducted on a multi-wavelength solar image dataset covering a full 11-year solar activity cycle. As a result, our method outperformed baseline approaches in terms of both the Gandin-Murphy-Gerrity score and the true skill statistic, which are standard metrics in terms of the performance and reliability.

cs.CV

Transformer-based Personalized Attention Mechanism for Medical Images with Clinical Records

In medical image diagnosis, identifying the attention region, i.e., the region of interest for which the diagnosis is made, is an important task. Various methods have been developed to automatically identify target regions from given medical images. However, in actual medical practice, the diagnosis is made based not only on the images but also on a variety of clinical records. This means that pathologists examine medical images with some prior knowledge of the patients and that the attention regions may change depending on the clinical records. In this study, we propose a method called the Personalized Attention Mechanism (PersAM), by which the attention regions in medical images are adaptively changed according to the clinical records. The primary idea of the PersAM method is to encode the relationships between the medical images and clinical records using a variant of Transformer architecture. To demonstrate the effectiveness of the PersAM method, we applied it to a large-scale digital pathology problem of identifying the subtypes of 842 malignant lymphoma patients based on their gigapixel whole slide images and clinical records.

eess.IV

Case-based Similar Image Retrieval for Weakly Annotated Large Histopathological Images of Malignant Lymphoma Using Deep Metric Learning

In the present study, we propose a novel case-based similar image retrieval (SIR) method for hematoxylin and eosin (H&E)-stained histopathological images of malignant lymphoma. When a whole slide image (WSI) is used as an input query, it is desirable to be able to retrieve similar cases by focusing on image patches in pathologically important regions such as tumor cells. To address this problem, we employ attention-based multiple instance learning, which enables us to focus on tumor-specific regions when the similarity between cases is computed. Moreover, we employ contrastive distance metric learning to incorporate immunohistochemical (IHC) staining patterns as useful supervised information for defining appropriate similarity between heterogeneous malignant lymphoma cases. In the experiment with 249 malignant lymphoma patients, we confirmed that the proposed method exhibited higher evaluation measures than the baseline case-based SIR methods. Furthermore, the subjective evaluation by pathologists revealed that our similarity measure using IHC staining patterns is appropriate for representing the similarity of H&E-stained tissue images for malignant lymphoma.

cs.CV

Multi-scale Domain-adversarial Multiple-instance CNN for Cancer Subtype Classification with Unannotated Histopathological Images

We propose a new method for cancer subtype classification from histopathological images, which can automatically detect tumor-specific features in a given whole slide image (WSI). The cancer subtype should be classified by referring to a WSI, i.e., a large-sized image (typically 40,000x40,000 pixels) of an entire pathological tissue slide, which consists of cancer and non-cancer portions. One difficulty arises from the high cost associated with annotating tumor regions in WSIs. Furthermore, both global and local image features must be extracted from the WSI by changing the magnifications of the image. In addition, the image features should be stably detected against the differences of staining conditions among the hospitals/specimens. In this paper, we develop a new CNN-based cancer subtype classification method by effectively combining multiple-instance, domain adversarial, and multi-scale learning frameworks in order to overcome these practical difficulties. When the proposed method was applied to malignant lymphoma subtype classifications of 196 cases collected from multiple hospitals, the classification performance was significantly better than the standard CNN or other conventional methods, and the accuracy compared favorably with that of standard pathologists.

cs.CV