SearcharxivSearch

arXiv subjects

Yuta Michimura

Publications and source records attributed to Yuta Michimura.

At least 37 records · Page 2Linked to original sources

Sagnac-type neutron displacement-noise-free interferometeric gravitational-wave detector

The detection of low-frequency gravitational waves on Earth requires the reduction of displacement noise, which dominates the low-frequency band. One method to cancel test mass displacement noise is a neutron displacement-noise-free interferometer (DFI). This paper proposes a new neutron DFI configuration, a Sagnac-type neutron DFI, which uses a Sagnac interferometer in place of the Mach-Zehnder interferometer. We demonstrate that a sensitivity of the Sagnac-type neutron DFI is higher than that of a conventional neutron DFI with the same interferometer scale. This configuration is particularly significant for neutron DFIs with limited space for construction and limited flux from available neutron sources.

gr-qc

Effects of mirror birefringence and its fluctuations to laser interferometric gravitational wave detectors

Crystalline materials are promising candidates as substrates or high-reflective coatings of mirrors to reduce thermal noises in future laser interferometric gravitational wave detectors. However, birefringence of such materials could degrade the sensitivity of gravitational wave detectors, not only because it can introduce optical losses, but also because its fluctuations create extra phase noise in the arm cavity reflected beam. In this paper, we analytically estimate the effects of birefringence and its fluctuations in the mirror substrate and coating for gravitational wave detectors. Our calculations show that the requirements for the birefringence fluctuations in silicon substrate and AlGaAs coating will be on the order of $10^{-8}$ and $10^{-10}$ rad/$\sqrt{\rm Hz}$ at 100~Hz, respectively, for future gravitational wave detectors. We also point out that optical cavity response needs to be carefully taken into account to estimate optical losses from depolarization.

astro-ph.IM

Optimization of quantum noise in space gravitational-wave antenna DECIGO with optical-spring quantum locking considering mixture of vacuum fluctuations in homodyne detection

Quantum locking using optical spring and homodyne detection has been devised to reduce quantum noise that limits the sensitivity of DECIGO, a space-based gravitational wave antenna in the frequency band around 0.1 Hz for detection of primordial gravitational waves. The reduction in the upper limit of energy density $Ω_{\mathrm{GW}}$ from $2{\times}10^{-15}$ to $1{\times}10^{-16}$, as inferred from recent observations, necessitates improved sensitivity in DECIGO to meet its primary science goals. To accurately evaluate the effectiveness of this method, this paper considers a detection mechanism that takes into account the influence of vacuum fluctuations on homodyne detection. In addition, an advanced signal processing method is devised to efficiently utilize signals from each photodetector, and design parameters for this configuration are optimized for the quantum noise. Our results show that this method is effective in reducing quantum noise, despite the detrimental impact of vacuum fluctuations on its sensitivity.

gr-qc

First-step experiment in developing optical-spring quantum locking for DECIGO: sensitivity optimization for simulated quantum noise by completing the square

DECi-hertz Interferometer Gravitational Wave Observatory (DECIGO) is a future mission for a space-borne laser interferometer. DECIGO has 1,000-km-long arm cavities mainly to detect the primordial gravitational waves (PGW) at lower frequencies around 0.1 Hz. Observations in the electromagnetic spectrum have lowered the bounds on the upper limit of PGW energy density ($Ω_{\rm gw} \sim 10^{-15} \to 10^{-16}$). As a result, DECIGO's target sensitivity, which is mainly limited by quantum noise, needs further improvement. To maximize the feasibility of detection while constrained by DECIGO's large diffraction loss, a quantum locking technique with an optical spring was theoretically proposed to improve the signal-to-noise ratio of the PGW. In this paper, we experimentally verify one key element of the optical-spring quantum locking: sensitivity optimization by completing the square of multiple detector outputs. This experiment is operated on a simplified tabletop optical setup with classical noise simulating quantum noise. We succeed in getting the best of the sensitivities with two different laser powers by the square completion method.

gr-qc

Photothermal effect in macroscopic optomechanical systems with an intracavity nonlinear optical crystal

Intracavity squeezing is a promising technique that may improve the sensitivity of gravitational wave detectors and cool optomechanical oscillators to the ground state. However, the photothermal effect may modify the occurrence of optomechanical coupling due to the presence of a nonlinear optical crystal in an optical cavity. We propose a novel method to predict the influence of the photothermal effect by measuring the susceptibility of the optomechanical oscillator and identifying the net optical spring constant and photothermal absorption rate. Using this method, we succeeded in precisely estimating parameters related to even minor photothermal effects, which could not be measured using a previously developed method.

quant-ph

Displacement-noise-free interferometeric gravitational-wave detector using unidirectional neutrons with four speeds

For further gravitational wave (GW) detections, it is significant to invent a technique to reduce all kinds of mirror displacement noise dominant at low frequencies for ground-based detectors. The neutron displacement-noise-free interferometer (DFI) is one of the tools to reduce all the mirror displacement noise at lower frequencies. In this paper, we describe a further simplified configuration of a neutron DFI in terms of neutron incidence direction. In the new configuration, neutrons enter the interferometer with unidirectional incidence at four speeds as opposed to two bidirectional incidences of opposite directions at two speeds as reported previously. This simplification of the neutron DFI is significant for proof-of-principle experiments.

gr-qc

Can the phase of radiation pressure fluctuations be flipped in a single path for laser interferometric gravitational wave detectors?

Radiation pressure (RP) noise, one component of quantum noise, can limit the sensitivity of laser interferometric gravitational wave (GW) detectors at lower frequencies. We conceived a possible RP noise cancellation method, using phase flipped ponderomotive-squeezed light (FPSL) incident on free-mass mirrors in interferometers' arms. This possibility is investigated under the constraint that the method is for space-based GW detectors in a broad frequency band lower than 1 Hz without using a long optical cavity. Considering various patterns in a single path small-scale case to generate the FPSL, we proved that no configuration exists in the single path case.

gr-qc

Wavefront Sensing with a Coupled Cavity for Torsion-Bar Antenna

Torsion-Bar Antenna (TOBA) is a ground-based gravitational wave detector using torsion pendulums. TOBA can detect intermediate-mass black hole binary mergers, gravitational wave stochastic background, and Newtonian noise, and is useful for earthquake early warning. A prototype detector Phase-III TOBA with 35 cm-scale pendulums is under development to demonstrate noise reduction. The target strain sensitivity is set to $1\times10^{-15}\,{/\sqrt{\rm Hz}}$ between 0.1 Hz--10 Hz. A new scheme of wavefront sensing with a coupled cavity was proposed to measure the pendulum rotation as low as $5\times10^{-16}\,{{\rm rad}/\sqrt{\rm Hz}}$ for Phase-III TOBA. In our method, an auxiliary cavity is used to enhance the first-order Hermite--Gaussian mode in a main cavity. Experimental demonstration is ongoing to confirm the feasibility of angular signal amplification and establish a method for locking a coupled cavity. We evaluated the performance of the coupled cavity and concluded that angular signal amplification would be feasible with this sensor. The coupled cavity was successfully locked to the resonance by the Pound--Drever--Hall technique with two modulation frequencies.

physics.ins-det

Angular trapping of a linear-cavity mirror with an optical torsional spring

Optomechanical systems have been attracting intensive attention in various physical experiments. With an optomechanical system, the displacement of or the force acting on a mechanical oscillator can be precisely measured by utilizing optical interferometry. As a mechanical oscillator, a suspended mirror is often used in over milligram scale optomechanical systems. However, the tiny suspended mirror in a linear cavity can be unstable in its yaw rotational degree of freedom due to optical radiation pressure. This instability curbs the optical power that the cavity can accumulate in it, and imposes a limitation on the sensitivity. Here, we show that the optical radiation pressure can be used to trap the rotational motion of the suspended mirror without additional active feedback control when the $g$ factors of the cavity are negative and one mirror is much heavier than the other one. Furthermore, we demonstrate experimentally the validity of the trapping. We measured the rotational stiffness of a suspended tiny mirror with various intracavity power. The result indicates that the radiation pressure of the laser beam inside the cavity actually works as a positive restoring torque. Moreover, we discuss the feasibility of observing quantum radiation pressure fluctuation with our experimental setup as an application of our trapping configuration.

quant-ph

Conceptual design and science cases of a juggled interferometer for gravitational wave detection

The Juggled interferometer (JIFO) is an earth-based gravitational wave detector using repeatedly free-falling test masses. With no worries of seismic noise and suspension thermal noise, the JIFO can have much better sensitivity at lower frequencies than the current earth-based gravitational wave detectors. The data readout method of a JIFO could be challenging if one adopts the fringe-locking method. We present a phase reconstruction method in this paper by building up a complex function which has a fringe-independent signal-to-noise ratio. Considering the displacement noise budget of the Einstein Telescope (ET), we show that the juggled test masses significantly improve the sensitivity at 0.1-2.5$\,$Hz even with discontinuous data. The science cases brought with the improved sensitivity would include detecting quasi-normal modes of black holes with $10^4-10^5\,M_{\odot}$, testing Brans-Dicke theory with black-hole and neutron-star inspirals, and detecting primordial-black-hole-related gravitational waves.

gr-qc

Neutron displacement noise-free interferometer for gravitational-wave detection

An interferometer design that cancels all displacement noises of its test masses and maintains a gravitational-wave (GW) signal by combining multiple detector signals is called a displacement noise-free interferometer (DFI). The idea has been considered previously for a laser interferometer. However, a limitation of a laser DFI is that its sensitive frequency band is too high for astrophysical GW sources, $\sim 10^5\,{\rm Hz}$ even for a kilometer-sized interferometer. To circumvent this limitation, in this paper, we propose a neutron DFI, in which neutrons are used instead of light. Since neutrons have velocities much lower than the speed of light, the sensitive frequency band of a neutron DFI can be lowered down to $\sim 10^{-1}\,{\rm Hz}$. Therefore, a neutron DFI can be utilized for detecting GWs that are inaccessible by an ordinary laser interferometer on the ground.

gr-qc

Stochastic effects on observation of ultralight bosonic dark matter

Ultralight bosonic particles are fascinating candidates of dark matter (DM). It behaves as classical waves in our Galaxy due to its large number density. There have been various methods proposed to search for the wave-like DM, such as methods utilizing interferometric gravitational-wave detectors. Understanding the characteristics of DM signals is crucial to extract the properties of DM from data. While the DM signal is nearly monochromatic with the angular frequency of its mass, the amplitude and phase are gradually changing due to the velocity dispersion of DMs in our Galaxy halo. The stochastic amplitude and phase should be properly taken into account to accurately constrain the coupling constant of DM from data. Previous works formulated a method to obtain the upper bound on the coupling constant incorporating the stochastic effects. One of these works compared the upper bound with and without the stochastic effect in a measurement time that is much shorter than the variation time scale of the amplitude and phase. In this paper, we extend their formulation to arbitrary measurement time and evaluate the stochastic effects. Moreover, we investigate the velocity-dependent signal for dark photon DM including an uncertainly of the velocity. We demonstrate that our method accurately estimates the upper bound on the coupling constant with numerical simulations. We also estimate the expected upper bound of the coupling constant of axion DM and dark photon DM from future experiments in a semi-analytic way. The stochasticity especially affects constraints on a small mass region. Our formulation offers a generic treatment of the ultralight bosonic DM signal with the stochastic effect.

astro-ph.CO

Displacement-noise-free neutron interferometer for gravitational wave detection using a single Mach-Zehnder configuration

The improvement of sensitivity to gravitational waves (GWs) at lower frequencies is still challenging on account of displacement noise. One of the solutions is the neutron displacement-noise-free interferometer (DFI). We focus on a simplification of the detector configuration by taking advantage of the ability to adjust the neutron speed depending on the configuration. The new configuration consists of two beamsplitters and two mirrors, which constitute a single Mach-Zehnder interferometer (MZI). It is simpler than the configuration with two MZIs in previous research. All displacement noise of mirrors and beamsplitters can be canceled in the frequency domain. This cancellation can be explained intuitively using a phasor diagram.

gr-qc

Ultralight dark matter searches with KAGRA gravitational wave telescope

Among various dark matter candidates, bosonic ultralight fields with masses below 1~eV are well motivated. Recently, a number of novel approaches have been put forward to search for ultralight dark matter candidates using laser interferometers at various scales. Those include our proposals to search for axion-like particles (ALPs) and vector fields with laser interferometric gravitational wave detectors. ALPs can be searched for by measuring the oscillating polarization rotation of laser light. Massive vector fields weakly coupled to the standard model sector can also be searched for by measuring the oscillating forces acting on the suspended mirrors of the interferometers. In this paper, the current status of the activities to search for such ultralight dark matter candidates using a gravitational wave detector in Japan, KAGRA, is reviewed. The analysis of data from KAGRA's observing run in 2020 to search for vector dark matter, and the installation of polarization optics to the arm cavity transmission ports of the interferometer to search for ALPs in future observing runs are underway.

hep-ph

First observation and analysis of DANCE: Dark matter Axion search with riNg Cavity Experiment

Dark matter Axion search with riNg Cavity Experiment (DANCE) was proposed to search for axion dark matter [Phys. Rev. Lett. 121, 161301 (2018)]. We aim to detect the rotation and oscillation of optical linear polarization caused by axion-photon coupling with a bow-tie cavity. DANCE can improve the sensitivity to axion-photon coupling constant $g_{a γ}$ for axion mass $m_a < 10^{-10}~\rm{eV}$ by several orders of magnitude compared to the best upper limits at present. A prototype experiment DANCE Act-1 is ongoing to demonstrate the feasibility of the method and to investigate technical noises. The optics was assembled and the performance of the cavity was evaluated. The first 12-day observation was successfully performed in May 2021. We reached $3 \times 10^{-6}~\rm{rad/\sqrt{Hz}}$ at $10~\rm{Hz}$ in the one-sided amplitude spectral density of the rotation angle of linear polarization.

physics.ins-det

Dark matter Axion search with riNg Cavity Experiment DANCE: Design and development of auxiliary cavity for simultaneous resonance of linear polarizations

Axion-like particles (ALPs) are undiscovered pseudo-scalar particles that are candidates for ultralight dark matter. ALPs interact with photons slightly and cause the rotational oscillation of linearly polarized light. Dark matter Axion search with riNg Cavity Experiment (DANCE) searches for ALP dark matter by amplifying the rotational oscillation with a bow-tie ring cavity. Simultaneous resonance of linear polarizations is necessary to amplify both the carrier field and the ALP signal, and to achieve the design sensitivity. The sensitivity of the current prototype experiment DANCE Act-1 is less than expectation by around three orders of magnitude due to the resonant frequency difference between s- and p-polarization in the bow-tie ring cavity. In order to tune the resonant frequency difference, the method of introducing an auxiliary cavity was proposed. We designed an auxiliary cavity that can cancel out the resonant frequency difference and realize simultaneous resonance, considering optical loss. We also confirmed that the sensitivity of DANCE Act-1 with the auxiliary cavity can reach the original sensitivity.

physics.ins-det

Axion dark matter search using arm cavity transmitted beams of gravitational wave detectors

Axion is a promising candidate for ultralight dark matter which may cause a polarization rotation of laser light. Recently, a new idea of probing the axion dark matter by optical linear cavities used in the arms of gravitational wave detectors has been proposed [Phys. Rev. Lett. 123, 111301 (2019)]. In this article, a realistic scheme of the axion dark matter search with the arm cavity transmission ports is revisited. Since photons detected by the transmission ports travel in the cavity for odd-number of times, the effect of axion dark matter on their phases is not cancelled out and the sensitivity at low-mass range is significantly improved compared to the search using reflection ports. We also take into account the stochastic nature of the axion field and the availability of the two detection ports in the gravitational wave detectors. The sensitivity to the axion-photon coupling, $g_{aγ}$, of the ground-based gravitational wave detector, such as Advanced LIGO, with 1-year observation is estimated to be $g_{aγ} \sim 3\times10^{-12}$ GeV$^{-1}$ below the axion mass of $10^{-15}$ eV, which improves upon the limit achieved by the CERN Axion Solar Telescope.

hep-ph

Improving force sensitivity by amplitude measurement of light reflected from a detuned optomechanical cavity

The measurement of weak continuous forces exerted on a mechanical oscillator is a fundamental problem in various physical experiments. It is fundamentally impeded by quantum back-action from the meter used to sense the displacement of the oscillator. In the context of interferometric displacement measurements, we here propose and demonstrate the working principle of a scheme for coherent back-action cancellation. By measuring the amplitude quadrature of the light reflected from a detuned optomechanical cavity inside which a stiff optical spring is generated, back-action can be cancelled in a narrow band of frequencies. This method provides a simple way to improve the sensitivity in experiments limited by quantum back-action without injection of squeezed light or stable homodyne readout.

quant-ph