Publications and source records attributed to Yuya Onishi.

11 recordsLinked to original sources

108 ps coincidence time resolution through optimized scintillators, photodetectors, readout electronics, and DOI-based timing correction in orthogonally stacked detector configurations

Objective. Existing commercial time-of-flight positron emission tomography (TOF-PET) systems yield a coincidence time resolution (CTR) of ~200 ps or less full width at half maximum (FWHM). Recently, there has been a challenge to achieve a CTR of 100 ps FWHM at the system level. However, current silicon photomultipliers (SiPMs) and 20-mm-thick scintillators in conventional single-ended readout scheme is difficult to achieve 100 ps CTR; the photon transport time spread (PTS) within the scintillator crystal is a major barrier. Differences in the interaction position result in variations in PTS on the order of several tens of ps, thereby degrading the CTR. A shorter scintillator can improve CTR; however, this can degrade detection efficiency. Approach. To overcome this trade-off between the CTR and detection efficiency, we previously proposed xDetector, an orthogonally stacked configuration along the longitudinal axis of scintillator crystals. We investigated the CTR potential of the xDetector by improving the scintillator, photodetector, and readout electronics, and by applying CTR correction based on a three-dimensional interaction within the scintillator. Main results. Based on error propagation, the CTR of the paired xDetector was calculated as 113.5 $\pm$ 2.7 ps FWHM. Furthermore, the CTR of the xDetector was measured at four positions along the longitudinal axis by manually sliding the xDetector, and the corrected achieved CTR was 108.6 $\pm$ 1.9 ps FWHM. Moreover, compared with the conventional single detector using a 20.0 mm scintillator, CTR improved by an average of 10.3%. Significance. The xDetector offers potential as a PET detector concept to achieve a CTR of 100 ps FWHM. Such timing performance is expected to improve TOF-PET image quality and quantitative accuracy, contributing to more reliable disease detection and diagnosis than current PET detectors.

physics.med-ph

Multi-Kernel TOF-PET Image Reconstruction Using ADMM

Time-of-flight positron emission tomography (TOF-PET) detectors exhibiting multiple coincidence time resolution (CTR) components, such as those induced by the mixing of Cherenkov and scintillation photons, have attracted increasing attention. However, to fully exploit the latent potential of multi-kernel TOF-PET, new iterative image reconstruction methods are required. In this study, assuming that the events are labeled with the appropriate kernels, we propose an alternating direction method of multipliers (ADMM) for multi-kernel TOF-PET reconstruction, termed TOF-decomp ADMM. As the convergence speed of the TOF-PET log-likelihood depends on the CTR, the proposed method splits the fast- and slow-CTR log-likelihood terms and optimizes them separately under a constraint. This strategy explicitly balances the contributions of fast- and slow-CTR components and enables early stopping at iterations that yield improved contrast-noise trade-offs compared with conventional methods. We validated the proposed method using brain and image quality phantom simulations, demonstrating improved contrast-noise characteristics from a more stabilized convergence. By addressing the convergence imbalance inherent to multi-kernel TOF-PET, this work establishes a framework for exploiting the timing information available in emerging detector technologies.

physics.med-ph

Machine learning enables experimental access to photon-by-photon arrival times in scintillation detectors

Scintillation detectors with excellent timing resolution enable more precise localization of radiation sources in positron emission tomography, leading to substantial improvements in diagnostic capability for diseases such as cancer and dementia. At the extreme timing precision required for such applications at the picosecond scale, detector performance is governed by the microscopic dynamics of scintillation photons generated within the detector and their subsequent detection processes. However, detector signals have conventionally been treated only as collective responses of many photons due to structural constraints inherent to photodetectors. In this study, we overcome this fundamental limitation using deep learning, enabling direct access to the timing information of individual photons. The proposed method estimates photon-by-photon arrival times directly from detector waveforms without requiring any modification to the detector structure; the method operates on an event-by-event basis without ground-truth labels by integrating an unsupervised learning framework with a physically informed detector-response model. Through comprehensive validation combining Monte Carlo simulation and experimental measurements across various detector configurations, we experimentally demonstrate improved timing resolution, visualized depth-of-interaction-dependent photon transport, and classified Cherenkov and scintillation photons based on the estimated photon-level timing information using a unified deep learning-based framework. These results provide experimental access to photon dynamics, bridging the gap between theoretical modeling and experimental observation, and they open a new data-driven pathway for discovery in detector physics and optimization.

physics.ins-det

Scintillator-integrated microchannel plate photomultiplier tubes for ultrafast timing over keV-GeV energy scales

Precise measurement of radiation has long played a vital role in a wide range of research and industrial fields, from fundamental physics beyond the Standard Model to medical imaging such as time-of-flight positron emission tomography. Developing radiation detectors that achieve high timing precision-on the order of a few tens of picoseconds-and energy measurement capabilities remains indispensable yet challenging. In this study, we developed two types of scintillator-integrated microchannel plate photomultiplier tubes (SCI-IMPs), one incorporating barium fluoride, and the other bismuth germanate, to enable simultaneous high-precision timing and energy measurements. To evaluate their performance over a wide energy range from keV- to GeV-scale, electron-positron annihilation gamma rays and cosmic ray muons were used. For energy measurements, both detectors achieved an energy resolution of approximately 35% at 511 keV. For timing measurements using 511 keV, coincidence time resolutions (CTRs) of approximately 50 ps full width at half maximum (FWHM) were obtained for both detectors. In contrast, for cosmic ray muon experiments where cosmic ray muon energy is typically on the order of GeV, CTRs were measured to be 25.1 and 16.8 ps FWHM for barium fluoride- and bismuth germanate-based detectors, respectively. The versatile scintillator-integration technique established in this study can broaden the applicability of the newly developed SCI-IMPs. In particular, these results demonstrate that the developed detectors push the boundaries of timing performance while retaining energy measurement and hold promise for future applications in fundamental physics experiments and medical imaging.

physics.ins-det

Exploiting network optimization stability for enhanced PET image denoising using deep image prior

PET is affected by statistical noise due to constraints on tracer dose and scan duration, impacting both diagnostic performance and quantitative accuracy. While deep learning (DL)-based PET denoising methods have been used to improve image quality, they may introduce over-smoothing, compromising quantitative accuracy. We propose a method for making a DL solution more reliable and apply it to the conditional deep image prior (DIP). We introduce the idea of stability information in the optimization process of conditional DIP, enabling the identification of unstable regions within the network's optimization trajectory. Our method incorporates a stability map, which is derived from multiple intermediate outputs of moderate network at different optimization steps. The final denoised image is then obtained by computing linear combination of the DIP output and the original reconstructed image, weighted by the stability map. Our method effectively reduces noise while preserving small structure details in brain FDG images. Results demonstrated that our approach outperformed existing methods in peak-to-valley ratio and noise suppression across various low-dose levels. Region-of-interest analysis confirmed that the proposed method maintains quantitative accuracy without introducing under- or over-estimation. We applied our method to full-dose PET data to assess its impact on image quality. The results revealed that the proposed method significantly reduced background noise while preserving the peak-to-valley ratio at a level comparable to that of unfiltered full-dose PET images. The proposed method introduces a robust approach to DL-based PET denoising, enhancing its reliability and preserving quantitative accuracy. This strategy has the potential to advance performance in high-sensitivity PET scanners, demonstrating that DL can extend PET imaging capabilities beyond low-dose applications.

physics.med-ph

Alleviating the trade-off between coincidence time resolution and sensitivity using scalable TOF-DOI detectors

Coincidence time resolution (CTR) in time-of-flight positron emission tomography (TOF-PET) has significantly improved with advancements in scintillators, photodetectors, and readout electronics. Achieving a CTR of 100 ps remains challenging due to the need for sufficiently thick scintillators-typically 20 mm-to ensure adequate sensitivity because the photon transit time spread within these thick scintillators impedes achieving 100 ps CTR. Therefore, thinner scintillators are preferable for CTR better than 100 ps. To address the trade-off between TOF capability and sensitivity, we propose a readout scheme of PET detectors. The proposed scheme utilizes two orthogonally stacked one-dimensional PET detectors, enabling the thickness of the scintillators to be reduced to approximately 13 mm without compromising sensitivity. This is achieved by stacking the detectors along the depth-of-interaction (DOI) axis of a PET scanner. We refer to this design as the cross-stacked detector, or xDetector. Furthermore, the xDetector inherently provides DOI information using the same readout scheme. Experimental evaluations demonstrated that the xDetector achieved a CTR of 175 ps FWHM and an energy resolution of 11% FWHM at 511 keV with 3 x 3 x 12.8 mm3 lutetium oxyorthosilicate crystals, each coupled one-to-one with silicon photomultipliers. In terms of xy-spatial resolution, the xDetector exhibited an asymmetric resolution due to its readout scheme: one resolution was defined by the 3.2 mm readout pitch, while the other was calculated using the center-of-gravity method. The xDetector effectively resolves the trade-off between TOF capability and sensitivity while offering scalability and DOI capability. By integrating state-of-the-art scintillators, photodetectors, and readout electronics with the xDetector scheme, achieving a CTR of 100 ps FWHM alongside high DOI resolution becomes a practical possibility.

physics.ins-det

List-Mode PET Image Reconstruction Using Dykstra-Like Splitting

Convergence of the block iterative method in image reconstruction for positron emission tomography (PET) requires careful control of relaxation parameters, which is a challenging task. The automatic determination of relaxation parameters for list-mode reconstructions also remains challenging. Therefore, a different approach would be desirable. In this study, we propose a list-mode maximum likelihood Dykstra-like splitting PET reconstruction (LM-MLDS). LM-MLDS converges the list-mode block iterative method by adding the distance from an initial image as a penalty term into an objective function. LM-MLDS takes a two-step approach because its performance depends on the quality of the initial image. The first step uses a uniform image as the initial image, and then the second step uses a reconstructed image after one main iteration as the initial image. In a simulation study, LM-MLDS provided a better tradeoff curve between noise and contrast than the other methods. In a clinical study, LM-MLDS removed the false hotspots at the edge of the axial field of view and improved the image quality of slices covering the top of the head to the cerebellum. List-mode proximal splitting reconstruction is useful not only for optimizing nondifferential functions but also for converging block iterative methods without controlling relaxation parameters.

physics.med-ph

Self-Supervised Pre-Training for Deep Image Prior-Based Robust PET Image Denoising

Deep image prior (DIP) has been successfully applied to positron emission tomography (PET) image restoration, enabling represent implicit prior using only convolutional neural network architecture without training dataset, whereas the general supervised approach requires massive low- and high-quality PET image pairs. To answer the increased need for PET imaging with DIP, it is indispensable to improve the performance of the underlying DIP itself. Here, we propose a self-supervised pre-training model to improve the DIP-based PET image denoising performance. Our proposed pre-training model acquires transferable and generalizable visual representations from only unlabeled PET images by restoring various degraded PET images in a self-supervised approach. We evaluated the proposed method using clinical brain PET data with various radioactive tracers ($^{18}$F-florbetapir, $^{11}$C-Pittsburgh compound-B, $^{18}$F-fluoro-2-deoxy-D-glucose, and $^{15}$O-CO$_{2}$) acquired from different PET scanners. The proposed method using the self-supervised pre-training model achieved robust and state-of-the-art denoising performance while retaining spatial details and quantification accuracy compared to other unsupervised methods and pre-training model. These results highlight the potential that the proposed method is particularly effective against rare diseases and probes and helps reduce the scan time or the radiotracer dose without affecting the patients.

physics.med-ph

Fully 3D Implementation of the End-to-end Deep Image Prior-based PET Image Reconstruction Using Block Iterative Algorithm

Deep image prior (DIP) has recently attracted attention owing to its unsupervised positron emission tomography (PET) image reconstruction, which does not require any prior training dataset. In this paper, we present the first attempt to implement an end-to-end DIP-based fully 3D PET image reconstruction method that incorporates a forward-projection model into a loss function. To implement a practical fully 3D PET image reconstruction, which could not be performed due to a graphics processing unit memory limitation, we modify the DIP optimization to block-iteration and sequentially learn an ordered sequence of block sinograms. Furthermore, the relative difference penalty (RDP) term was added to the loss function to enhance the quantitative PET image accuracy. We evaluated our proposed method using Monte Carlo simulation with [$^{18}$F]FDG PET data of a human brain and a preclinical study on monkey brain [$^{18}$F]FDG PET data. The proposed method was compared with the maximum-likelihood expectation maximization (EM), maximum-a-posterior EM with RDP, and hybrid DIP-based PET reconstruction methods. The simulation results showed that the proposed method improved the PET image quality by reducing statistical noise and preserved a contrast of brain structures and inserted tumor compared with other algorithms. In the preclinical experiment, finer structures and better contrast recovery were obtained by the proposed method. This indicated that the proposed method can produce high-quality images without a prior training dataset. Thus, the proposed method is a key enabling technology for the straightforward and practical implementation of end-to-end DIP-based fully 3D PET image reconstruction.

physics.med-ph

List-Mode PET Image Reconstruction Using Deep Image Prior

List-mode positron emission tomography (PET) image reconstruction is an important tool for PET scanners with many lines-of-response and additional information such as time-of-flight and depth-of-interaction. Deep learning is one possible solution to enhance the quality of PET image reconstruction. However, the application of deep learning techniques to list-mode PET image reconstruction has not been progressed because list data is a sequence of bit codes and unsuitable for processing by convolutional neural networks (CNN). In this study, we propose a novel list-mode PET image reconstruction method using an unsupervised CNN called deep image prior (DIP) which is the first trial to integrate list-mode PET image reconstruction and CNN. The proposed list-mode DIP reconstruction (LM-DIPRecon) method alternatively iterates the regularized list-mode dynamic row action maximum likelihood algorithm (LM-DRAMA) and magnetic resonance imaging conditioned DIP (MR-DIP) using an alternating direction method of multipliers. We evaluated LM-DIPRecon using both simulation and clinical data, and it achieved sharper images and better tradeoff curves between contrast and noise than the LM-DRAMA, MR-DIP and sinogram-based DIPRecon methods. These results indicated that the LM-DIPRecon is useful for quantitative PET imaging with limited events while keeping accurate raw data information. In addition, as list data has finer temporal information than dynamic sinograms, list-mode deep image prior reconstruction is expected to be useful for 4D PET imaging and motion correction.

physics.med-ph

Anatomical-Guided Attention Enhances Unsupervised PET Image Denoising Performance

Although supervised convolutional neural networks (CNNs) often outperform conventional alternatives for denoising positron emission tomography (PET) images, they require many low- and high-quality reference PET image pairs. Herein, we propose an unsupervised 3D PET image denoising method based on an anatomical information-guided attention mechanism. The proposed magnetic resonance-guided deep decoder (MR-GDD) utilizes the spatial details and semantic features of MR-guidance image more effectively by introducing encoder-decoder and deep decoder subnetworks. Moreover, the specific shapes and patterns of the guidance image do not affect the denoised PET image, because the guidance image is input to the network through an attention gate. In a Monte Carlo simulation of [$^{18}$F]fluoro-2-deoxy-D-glucose (FDG), the proposed method achieved the highest peak signal-to-noise ratio and structural similarity (27.92 $\pm$ 0.44 dB/0.886 $\pm$ 0.007), as compared with Gaussian filtering (26.68 $\pm$ 0.10 dB/0.807 $\pm$ 0.004), image guided filtering (27.40 $\pm$ 0.11 dB/0.849 $\pm$ 0.003), deep image prior (DIP) (24.22 $\pm$ 0.43 dB/0.737 $\pm$ 0.017), and MR-DIP (27.65 $\pm$ 0.42 dB/0.879 $\pm$ 0.007). Furthermore, we experimentally visualized the behavior of the optimization process, which is often unknown in unsupervised CNN-based restoration problems. For preclinical (using [$^{18}$F]FDG and [$^{11}$C]raclopride) and clinical (using [$^{18}$F]florbetapir) studies, the proposed method demonstrates state-of-the-art denoising performance while retaining spatial resolution and quantitative accuracy, despite using a common network architecture for various noisy PET images with 1/10th of the full counts. These results suggest that the proposed MR-GDD can reduce PET scan times and PET tracer doses considerably without impacting patients.

physics.med-ph