First application of mass measurement with the Rare-RI Ring reveals the solar r-process abundance trend at A=122 and A=123

The Rare-RI Ring (R3) is a recently commissioned cyclotron-like storage ring mass spectrometer dedicated to mass measurements of exotic nuclei far from stability at Radioactive Isotope Beam Factory (RIBF) in RIKEN. The first application of mass measurement using the R3 mass spectrometer at RIBF is reported. Rare isotopes produced at RIBF, $^{127}$Sn, $^{126}$In, $^{125}$Cd, $^{124}$Ag, $^{123}$Pd, were injected in R3. Masses of $^{126}$In, $^{125}$Cd, and $^{123}$Pd were measured whereby the mass uncertainty of $^{123}$Pd was improved. This is the first reported measurement with a new storage ring mass spectrometery technique realized at a heavy-ion cyclotron and employing individual injection of the pre-identified rare nuclei. The latter is essential for the future mass measurements of the rarest isotopes produced at RIBF. The impact of the new $^{123}$Pd result on the solar $r$-process abundances in a neutron star merger event is investigated by performing reaction network calculations of 20 trajectories with varying electron fraction $Y_e$. It is found that the neutron capture cross section on $^{123}$Pd increases by a factor of 2.2 and $β$-delayed neutron emission probability, $P_\mathrm{1n}$, of $^{123}$Rh increases by 14\%. The neutron capture cross section on $^{122}$Pd decreases by a factor of 2.6 leading to pileup of material at $A=122$, thus reproducing the trend of the solar $r$-process abundances. The trend of the two-neutron separation energies (S$_\mathrm{2n}$) was investigated for the Pd isotopic chain. The new mass measurement with improved uncertainty excludes large changes of the S$_\mathrm{2n}$ value at $N=77$. Such large increase of the S$_\mathrm{2n}$ values before $N=82$ was proposed as an alternative to the quenching of the $N=82$ shell gap to reproduce $r$-process abundances in the mass region of $A=112-124$.

nucl-ex↗

Direct determination of the atomic mass difference of the pairs $^{76}$As-$^{76}$Se and $^{155}$Tb-$^{155}$Gd rules out $^{76}$As and $^{155}$Tb as possible candidates for electron (anti)neutrino mass measurements

The first direct determination of the ground-state-to-ground-state $Q$ values of the $β^-$ decay $^{76}$As $\rightarrow$ $^{76}$Se and the electron-capture decay $^{155}$Tb $\rightarrow$ $^{155}$Gd was performed utilizing the double Penning trap mass spectrometer JYFLTRAP. By measuring the atomic mass difference of the decay pairs via the phase-imaging ion-cyclotron-resonance (PI-ICR) technique, the $Q$ values of $^{76}$As $\rightarrow$ $^{76}$Se and $^{155}$Tb $\rightarrow$ $^{155}$Gd were determined to be 2959.265(74) keV and 814.94(18) keV, respectively. The precision was increased relative to earlier measurements by factors of 12 and 57, respectively. The new $Q$ values are 1.33 keV and 5 keV lower compared to the values adopted in the most recent Atomic Mass Evaluation 2020. With the newly determined ground-state-to-ground-state $Q$ values combined with the excitation energy from $γ$-ray spectroscopy, the $Q$ values for ground-state-to-excited-state transitions $^{76}$As (ground state) $\rightarrow$ $^{76}$Se$^*$ (2968.4(7) keV) and $^{155}$Tb (ground state) $\rightarrow$ $^{155}$Gd$^*$ (815.731(3) keV) were derived to be -9.13(70) keV and -0.79(18) keV. Thus we have confirmed that both of the $β^{-}$-decay and EC-decay candidate transitions are energetically forbidden at a level of at least 4$σ$, thus definitely excluding these two cases from the list of potential candidates for the search of low-$Q$-value $β^-$ or EC decays to determine the electron-(anti)neutrino mass.

nucl-ex↗

High-precision electron-capture $Q$ value measurement of $^{111}$In for electron-neutrino mass determination

A precise determination of the ground state $^{111}$In ($9/2^+$) electron capture to ground state of $^{111}$Cd ($1/2^+$) $Q$ value has been performed utilizing the double Penning trap mass spectrometer, JYFLTRAP. A value of 857.63(17) keV was obtained, which is nearly a factor of 20 more precise than the value extracted from the Atomic Mass Evaluation 2020 (AME2020). The high-precision electron-capture $Q$ value measurement along with the nuclear energy level data of 866.60(6) keV, 864.8(3) keV, 855.6(10) keV, and 853.94(7) keV for $^{111}$Cd was used to determine whether the four states are energetically allowed for a potential ultra-low $Q$-value $β^{}$ decay or electron-capture decay. Our results confirm that the excited states of 866.60(6) keV with spin-parity ($J^π$) of 3/2$^{+}$ and 864.8(3) keV with $J^π$ = 3/2$^{+}$ are ruled out due to their deduced electron-capture $Q$ value being smaller than 0 keV at the level of around 20$σ$ and 50$σ$, respectively. Electron-capture decays to the excited states at 853.94(7) keV ($J^π$ = 7/2$^+$) and 855.6(10) keV ($J^π$ = 3/2$^+$), are energetically allowed with $Q$ values of 3.69(19) keV and 2.0(10) keV, respectively. The allowed decay transition $^{111}$In (9/2$^{+}$) $\rightarrow$ $^{111}$Cd (7/2$^{+}$), with a $Q$ value of 3.69(19) keV, is a potential a new candidate for neutrino-mass measurements by future EC experiments featuring new powerful detection technologies. The results show that the indium level $2p_{1/2}$ for this decay branch leads to a significant increase in the number of EC events in the energy region sensitive to the electron neutrino mass.

nucl-ex↗

$^{159}$Dy electron-capture: a strong new candidate for neutrino mass determination

{ The ground-state to ground-state electron-capture $Q$ value of $^{159}$Dy ($3/2^-$) has been measured directly utilizing the double Penning trap mass spectrometer JYFLTRAP. A value of 364.73(19)~keV was obtained from a measurement of the cyclotron frequency ratio of the decay parent $^{159}$Dy and the decay daughter $^{159}$Tb ions using the novel phase-imaging ion-cyclotron resonance technique. The $Q$ values for allowed Gamow-Teller transition to $5/2^-$ and the third-forbidden unique transition to $11/2^+$ state with excitation energies of 363.5449(14)~keV and 362.050(40)~keV in $^{159}$Tb were determined to be 1.18(19) keV and 2.68(19) keV, respectively. The high-precision $Q$ value of transition $3/2^-\to 5/2^-$ from this work, revealing itself as the lowest electron-capture $Q$ value, is utilized to unambiguously characterise all the possible lines that are present in its electron capture spectrum. { We performed atomic many-body calculations for both transitions to determine electron-capture probabilities from various atomic orbitals, and found an order of magnitude enhancement in the event rates near the end-point of energy spectrum in the transition to the $5/2^-$ nuclear excited state, which can become very interesting once the experimental challenges of identifying decays into excited states are overcome. The transition to the $11/2^+$ state is strongly suppressed and found unsuitable for measuring the neutrino mass. These results show that the electron capture in the $^{159}$Dy atom, going to the $5/2^-$ state of the $^{159}$Tb nucleus, %\textcolor{red} {is a new candidate which may open the way to determine the electron-neutrino mass in the sub-eV region by studying EC. Further experimental feasibility studies, including coincidence measurements with realistic detectors, will be of great interest.} }

nucl-ex↗

High-precision $Q$-value measurement and nuclear matrix elements for the double-$β$ decay of $^{98}$Mo

Neutrinoless double-beta ($0νββ$) decay and the standard two-neutrino double-beta ($2νββ$) decay of $^{98}$Mo have been studied. The double-beta decay $Q$-value has been determined as $Q_{ββ}=113.668(68)$ keV using the JYFLTRAP Penning trap mass spectrometer. It is in agreement with the literature value, $Q_{ββ}=109(6)$ keV, but almost 90 times more precise. Based on the measured $Q$-value, precise phase-space factors for $2νββ$ decay and $0νββ$ decay, needed in the half-life predictions, have been calculated. Furthermore, the involved nuclear matrix elements have been computed in the proton-neutron quasiparticle random-phase approximation (pnQRPA) and the microscopic interacting boson model (IBM-2) frameworks. Finally, predictions for the $2νββ$ decay are given, suggesting a much longer half-life than for the currently observed cases.

nucl-ex↗

Study of radial motion phase advance during motion excitations in a Penning trap and accuracy of JYFLTRAP mass spectrometer

Phase-imaging ion-cyclotron-resonance technique has been implemented at the Penning-trap mass spectrometer JYFLTRAP and is routinely employed for mass measurements of stable and short-lived nuclides produced at IGISOL facility. Systematic uncertainties that impose limitations on the accuracy of measurements are discussed. It was found out that the phase evolution of the radial motion of ions in a Penning trap during the application of radio-frequency fields leads to a systematic cyclotron frequency shift when more than one ion species is present in the trap during the cyclotron frequency measurement. An analytic expression was derived to correctly account for the shift. Cross-reference mass measurements with carbon-cluster ions have been performed providing the mass-dependent and residual uncertainties.

physics.ins-det↗

Simulation-based design study for the passive shielding of the COSINUS dark matter experiment

The COSINUS (Cryogenic Observatory for SIgnatures seen in Next-generation Underground Searches) experiment aims at the detection of dark matter-induced recoils in sodium iodide (NaI) crystals operated as scintillating cryogenic calorimeters. The detection of both scintillation light and phonons allows performing an event-by-event signal to background discrimination, thus enhancing the sensitivity of the experiment. The construction of the experimental facility is foreseen to start by 2021 at the INFN Gran Sasso National Laboratory (LNGS) in Italy. It consists of a cryostat housing the target crystals shielded from the external radioactivity by a water tank acting, at the same time, as an active veto against cosmic ray-induced events. Taking into account both environmental radioactivity and intrinsic contamination of materials used for cryostat, shielding and infrastructure, we performed a careful background budget estimation. The goal is to evaluate the number of events that could mimic or interfere with signal detection while optimising the geometry of the experimental setup. In this paper we present the results of the detailed Monte Carlo simulations we performed, together with the final design of the setup that minimises the residual amount of background particles reaching the detector volume.

physics.ins-det↗

Direct measurement of the mass difference of $^{72}$As-$^{72}$Ge rules out $^{72}$As as a promising $β$-decay candidate to determine the neutrino mass

We report the first direct determination of the ground-state to ground-state electron-capture $Q$-value for the $^{72}$As to $^{72}$Ge decay by measuring their atomic mass difference utilizing the double Penning trap mass spectrometer, JYFLTRAP. The $Q$-value was measured to be 4343.596(75)~keV, which is more than a 50-fold improvement in precision compared to the value in the most recent Atomic Mass Evaluation 2020. Furthermore, the new $Q$-value was found to be 12.4(40)~keV (3.1 $σ$) lower. With the significant reduction of the uncertainty of the ground-state to ground-state $Q$-value value combined with the level scheme of $^{72}$Ge from $γ$-ray spectroscopy, we confirm that the five potential ultra-low $Q$-value ${β^{+}}$-decay or electron capture transitions are energetically forbidden, thus precluding all the transitions as possible candidates for the electron neutrino mass determination. However, the discovery of small negative $Q$-values opens up the possibility to use $^{72}$As for the study of virtual $β$-$γ$ transitions.

nucl-ex↗

Development and operation of an electrostatic time-of-flight detector for the Rare RI storage Ring

An electrostatic time-of-flight detector named E-MCP has been developed for quick diagnostics of circulating beam and timing measurement in mass spectrometry at the Rare-RI Ring in RIKEN. The E-MCP detector consists of a conversion foil, potential grids, and a microchannel plate. Secondary electrons are released from the surface of the foil when a heavy ion hits it. The electrons are accelerated and deflected by 90$^\circ$ toward the microchannel plate by electrostatic potentials. A thin carbon foil and a thin aluminum-coated mylar foil were used as conversion foils. We obtained time resolutions of 69(1) ps and 43(1) ps (standard deviation) for a $^{84}$Kr beam at an energy of 170 MeV/u when using the carbon and the aluminum-coated mylar foils, respectively. A detection efficiency of approximately 90% was obtained for both foils. The E-MCP detector equipped with the carbon foil was installed inside the Rare-RI Ring to confirm particle circulation within a demonstration experiment on mass measurements of nuclei around $^{78}$Ge produced by in-flight fission of uranium beam at the RI Beam Factory in RIKEN. Periodic time signals from circulating ions were clearly observed. Revolution times for $^{78}$Ge, $^{77}$Ga, and $^{76}$Zn were obtained. The results confirmed successful circulation of the short-lived nuclei inside the Rare-RI Ring.

physics.ins-det↗

High-precision mass measurement of $^{168}$Yb for verification of nonlinear isotope shift

The absolute mass value of $^{168}$Yb has been directly determined with the JYFLTRAP Penning trap mass spectrometer at the Ion Guide Isotope Separator On-Line (IGISOL) facility. A more precise value of the mass of $^{168}$Yb is needed to extract possible signatures of beyond standard model physics from high-precision isotope shift measurements of Yb atomic transition frequencies. The measured mass-excess value, ME($^{168}$Yb) = $-$61579.846(94) keV, is 12 times more precise and deviates from the Atomic Mass Evaluation 2016 value by 1.7$σ$. The impact on precision isotope shift studies of the stable Yb isotopes is discussed.

nucl-ex↗

HPRL -- International cooperation to identify and monitor priority nuclear data needs for nuclear applications

The OECD-NEA High Priority Request List (HPRL) is a point of reference to guide and stimulate the improvement of nuclear data for nuclear energy and other applications, and a tool to bridge the gap between data users and producers. The HPRL is application-driven and the requests are submitted by nuclear data users or representatives of the user's communities. A panel of international experts reviews and monitors the requests in the framework of an Expert Group mandated by the NEA Nuclear Science Committee Working Party on International Nuclear Data Evaluation Cooperation (WPEC). After approval, individual requests are classified to three categories: high priority requests, general requests, and special purpose requests (e.g., dosimetry, standards). The HPRL is hosted by the NEA in the form of a relational database publicly available on the web. This paper provides an overview of HPRL entries, status and outlook. Examples of requests successfully completed are given and new requests are described with emphasis on updated nuclear data needs in the fields of nuclear energy, neutron standards and dosimetry.

nucl-ex↗

Towards a More Complete and Accurate Experimental Nuclear Reaction Data Library (EXFOR): International Collaboration Between Nuclear Reaction Data Centres (NRDC)

The International Network of Nuclear Reaction Data Centres (NRDC) coordinated by the IAEA Nuclear Data Section (NDS) is successfully collaborating in the maintenance and development of the EXFOR library. As the scope of published data expands (e.g., to higher energy, to heavier projectile) to meet the needs from the frontier of sciences and applications, it becomes nowadays a hard and challenging task to maintain both completeness and accuracy of the whole EXFOR library. The paper describes evolution of the library with highlights on recent developments.

nucl-ex↗

Masses of neutron-rich $^{\operatorname{52-54}}$Sc and $^{54,56}$Ti nuclides: The $N=32$ subshell closure in scandium

Isochronous mass spectrometry has been applied in the storage ring CSRe to measure the masses of the neutron-rich $^{\operatorname{52-54}}$Sc and $^{54,56}$Ti nuclei. The new mass excess values $ME$($^{52}$Sc) $=$ $-40525(65)$ keV, $ME$($^{53}$Sc) $=$ $-38910(80)$ keV, and $ME$($^{54}$Sc) $=$ $-34485(360)$ keV, deviate from the Atomic Mass Evaluation 2012 by 2.3$σ$, 2.8$σ$, and 1.7$σ$, respectively. These large deviations significantly change the systematics of the two-neutron separation energies of scandium isotopes. The empirical shell gap extracted from our new experimental results shows a significant subshell closure at $N = 32$ in scandium, with a similar magnitude as in calcium. Moreover, we present $ab$ $initio$ calculations using the valence-space in-medium similarity renormalization group based on two- and three-nucleon interactions from chiral effective field theory. The theoretical results confirm the existence of a substantial $N = 32$ shell gap in Sc and Ca with a decreasing trend towards lighter isotones, thus providing a consistent picture of the evolution of the $N = 32$ magic number from the $pf$ into the $sd$ shell.

nucl-ex↗

Study of multi-neutron systems with SAMURAI spectrometer

The tetraneutron has been drawing the attention of the nuclear physics community for decades, but a firm conclusion on its existence and properties is still far from being reached despite many experimental and theoretical efforts. New measurements have recently been performed at RIBF with the SAMURAI spectrometer by applying complementary reaction probes, which will help to pin down the properties of this four-neutron system.

nucl-ex↗

Application of isochronous mass spectrometry for the study of angular momentum population in projectile fragmentation reactions

Isochronous mass spectrometry was applied to measure isomeric yield ratios of fragmentation reaction products. This approach is complementary to conventional gamma-ray spectroscopy in particular for measuring yield ratios for long-lived isomeric states. Isomeric yield ratios for the high-spin I = 19/2 states in the mirror nuclei 53Fe and 53Co are measured to study angular momentum population following the projectile fragmentation of 78Kr at energies of 480A MeV on a beryllium target. The 19/2 state isomeric ratios of 53Fe produced from different projectiles in the literature have also been extracted as a function of mass number difference between projectile and fragment (mass loss). The results are compared to ABRABLA07 model calculations. The isomeric ratios of 53Fe produced using different projectiles suggest that the theory underestimates not only the previously reported dependence on the spin but also the dependence on the mass loss.

nucl-ex↗

Enriched TeO$_2$ bolometers with active particle discrimination: towards the CUPID experiment

We present the performances of two 92% enriched $^{130}$TeO$_2$ crystals operated as thermal bolometers in view of a next generation experiment to search for neutrinoless double beta decay of $^{130}$Te. The crystals, 435 g each, show an energy resolution, evaluated at the 2615 keV $γ$-line of $^{208}$Tl, of 6.5 and 4.3 keV FWHM. The only observable internal radioactive contamination arises from $^{238}$U (15 and 8 $μ$Bq/kg, respectively). The internal activity of the most problematic nuclei for neutrinoless double beta decay, $^{226}$Ra and $^{228}$Th, are both evaluated as $<$3.1 $μ$Bq/kg for one crystal and $<$2.3 $μ$Bq/kg for the second. Thanks to the readout of the weak Cherenkov light emitted by $β/γ$ particles by means of Neganov-Luke bolometric light detectors we were able to perform an event-by-event identification of $β/γ$ events with a 95% acceptance level, while establishing a rejection factor of 98.21% and 99.99% for $α$ particles.

physics.ins-det↗

An improvement of isochronous mass spectrometry: Velocity measurements using two time-of-flight detectors

Isochronous mass spectrometry (IMS) in storage rings is a powerful tool for mass measurements of exotic nuclei with very short half-lives down to several tens of microseconds, using a multicomponent secondary beam separated in-flight without cooling. However, the inevitable momentum spread of secondary ions limits the precision of nuclear masses determined by using IMS. Therefore, the momentum measurement in addition to the revolution period of stored ions is crucial to reduce the influence of the momentum spread on the standard deviation of the revolution period, which would lead to a much improved mass resolving power of IMS. One of the proposals to upgrade IMS is that the velocity of secondary ions could be directly measured by using two time-of-flight (double TOF) detectors installed in a straight section of a storage ring. In this paper, we outline the principle of IMS with double TOF detectors and the method to correct the momentum spread of stored ions.

physics.ins-det↗

Accurate correction of magnetic field instabilities for high-resolution isochronous mass measurements in storage rings

Isochronous mass spectrometry (IMS) in storage rings is a successful technique for accurate mass measurements of short-lived nuclides with relative precision of about $10^{-5}-10^{-7}$. Instabilities of the magnetic fields in storage rings are one of the major contributions limiting the achievable mass resolving power, which is directly related to the precision of the obtained mass values. A new data analysis method is proposed allowing one to minimise the effect of such instabilities. The masses of the previously measured at the CSRe $^{41}$Ti, $^{43}$V, $^{47}$Mn, $^{49}$Fe, $^{53}$Ni and $^{55}$Cu nuclides were re-determined with this method. An improvement of the mass precision by a factor of $\sim 1.7$ has been achieved for $^{41}$Ti and $^{43}$V. The method can be applied to any isochronous mass experiment irrespective of the accelerator facility. Furthermore, the method can be used as an on-line tool for checking the isochronous conditions of the storage ring.