Searcharxiv⌕ Search

arXiv subjects

Z. Liu

Publications and source records attributed to Z. Liu.

183 records · Page 11Linked to original sources

Anisotropic flow at RHIC: How unique is the number-of-constituent-quark scaling?

The transverse momentum dependence of the anisotropic flow $v_2$ for $π$, $K$, nucleon, $Λ$, $Ξ$ and $Ω$ is studied for Au+Au collisions at $\sqrt{s_{\rm NN}} = 200$ GeV within two independent string-hadron transport approaches (RQMD and UrQMD). Although both models reach only 60% of the absolute magnitude of the measured $v_2$, they both predict the particle type dependence of $v_2$, as observed by the RHIC experiments: $v_2$ exhibits a hadron-mass hierarchy (HMH) in the low $p_T$ region and a number-of-constituent-quark (NCQ) dependence in the intermediate $p_T$ region. The failure of the hadronic models to reproduce the absolute magnitude of the observed $v_2$ indicates that transport calculations of heavy ion collisions at RHIC must incorporate interactions among quarks and gluons in the early, hot and dense phase. The presence of an NCQ scaling in the string-hadron model results suggests that the particle-type dependencies observed in heavy-ion collisions at intermediate $p_T$ might be related to the hadronic cross sections in vacuum rather than to the hadronization process itself.

nucl-th↗

The TOFp/pVPD Time of Flight System for STAR

A time-of-flight system was constructed for the STAR Experiment for the direct identification of hadrons produced in 197Au+197Au collisions at RHIC. The system consists of two separate detector subsystems, one called the pVPD (the "start" detector) and the other called the TOFp tray (the "stop" detector). Each detector is based on conventional scintillator/phototube technology and includes custom high-performance front-end electronics and a common CAMAC-based digitization and read-out. The design of the system and its performance during the 2001 RHIC run will be described. The start resolution attained by the pVPD was 24 ps, implying a pVPD single-detector resolution of 58 ps. The total time resolution of the system averaged over all detector channels was 87 ps, allowing direct pi/K/p discrimination for momenta up to 1.8 GeV/c, and direct (pi+K)/p discrimination up to 3 GeV/c.

nucl-ex↗

Measurement of Change of 7Be Decay Rate in Be and Au

We have measured the possible change of the decay rate of 7Be implanted into hosts of natural beryllium and natural gold. No difference between the 7Be decay rates in the two hosts is observed within the experimental precision of 0.12%. This result implies that change of the decay rate of 7Be implanted in different materials cannot be simply expected from the electron affinity difference consideration lonely and the lattice structure of the host materials should be taken into account.

nucl-ex↗