Searcharxiv⌕ Search

arXiv subjects

Z. Slavkovská

Publications and source records attributed to Z. Slavkovská.

6 recordsLinked to original sources

Photomultiplier Requirements and Pre-Calibration for the SABRE South Liquid Scintillator Veto

We present a study of the oil-proof base Hamamatsu R5912 photomultiplier tubes that will be used in the SABRE South linear-alkylbenzene liquid scintillator veto. SABRE South is a dark matter direct detection experiment at the Stawell Underground Physics Laboratory, aiming to test the DAMA/LIBRA dark matter annual modulation signal. We discuss the requirements of the liquid scintillator system and its photomultipliers, outline the methods and analysis used for the characterisation measurements, and results from initial tests. We discuss the impact of these measurements on the performance of the active veto system and explore analysis methods to allow for low threshold operation. Finally, we include results from a small scale liquid scintillator detector prototype used to assess the future performance of pulse shape discrimination in the liquid scintillator veto, and how well accommodated it is by the R5912 PMTs.

physics.ins-det↗

The SABRE South Technical Design Report Executive Summary

In this technical design report (TDR) executive summary we describe the SABRE South detector to be built at the Stawell Underground Physics Laboratory (SUPL). The SABRE South detector is designed to test the long-standing DAMA/LIBRA signal of an annually modulating rate consistent with dark matter by using the same target material. Located in the Southern Hemisphere, the detector is uniquely positioned to disentangle modulating seasonal effects. SABRE South uses seven ultra-high purity NaI(Tl) crystals (with a total target mass of either 35 kg or 50 kg), hermetically sealed in copper enclosures that are suspended within a liquid scintillator active veto. High quantum efficiency and low background Hamamatsu R11065 photomultiplier tubes are directly coupled to both ends of the crystal, and enclosed with the crystal in an oxygen free copper enclosure. The active veto system consists of 11.6 kL of linear alkylbenzene (LAB) doped with a mixture of fluorophores and contained in a steel vessel, which is instrumented with at least 18 Hamamatsu R5912 photomultipliers. The active veto tags key radiogenic backgrounds intrinsic to the crystals, such as ${^{40}}$K, and is expected to suppress the total background by 27% in the 1-6 keV region of interest. In addition to the liquid scintillator veto, a muon veto is positioned above the detector shielding. This muon veto consists of eight EJ-200 scintillator modules, with Hamamatsu R13089 photomultipliers coupled to both ends. With an expected total background of 0.72 cpd/kg/keV, SABRE South can test the DAMA/LIBRA signal with 5$σ$ discovery or 3$σ$ exclusion after two years of data taking.

physics.ins-det↗

Simulation and background characterisation of the SABRE South experiment

SABRE (Sodium iodide with Active Background REjection) is a direct detection dark matter experiment based on arrays of radio-pure NaI(Tl) crystals. The experiment aims at achieving an ultra-low background rate and its primary goal is to confirm or refute the results from the DAMA/LIBRA experiment. The SABRE Proof-of-Principle phase was carried out in 2020-2021 at the Gran Sasso National Laboratory (LNGS), in Italy. The next phase consists of two full-scale experiments: SABRE South at the Stawell Underground Physics Laboratory, in Australia, and SABRE North at LNGS. This paper focuses on SABRE South and presents a detailed simulation of the detector, which is used to characterise the background for dark matter searches including DAMA/LIBRA-like modulation. We estimate an overall background of 0.72 cpd/kg/keV$_{ee}$ in the energy range 1$-$6 keV$_{ee}$ primarily due to radioactive contamination in the crystals. Given this level of background and considering that the SABRE South has a target mass of 50 kg, we expect to exclude (confirm) DAMA/LIBRA modulation at $4~(5)σ$ within 2.5 years of data taking.

physics.ins-det↗

Electron capture of Xe$^{54+}$ in collisions with H${_2}$ molecules in the energy range between 5.5 MeV/u and 30.9 MeV/u

The electron capture process was studied for Xe$^{54+}$ colliding with H$_2$ molecules at the internal gas target of the ESR storage ring at GSI, Darmstadt. Cross section values for electron capture into excited projectile states were deduced from the observed emission cross section of Lyman radiation, being emitted by the hydrogen-like ions subsequent to the capture of a target electron. The ion beam energy range was varied between 5.5 MeV/u and 30.9 MeV/u by applying the deceleration mode of the ESR. Thus, electron capture data was recorded at the intermediate and in particular the low collision energy regime, well below the beam energy necessary to produce bare xenon ions. The obtained data is found to be in reasonable qualitative agreement with theoretical approaches, while a commonly applied empirical formula significantly overestimates the experimental findings.

physics.atom-ph↗

Approaching the Gamow window with stored ions: Direct measurement of $^{124}$Xe(p,$γ$) in the ESR storage ring

We report the first measurement of low-energy proton-capture cross sections of $^{124}$Xe in a heavy ion storage ring. $^{124}$Xe$^{54+}$ ions of five different beam energies between 5.5 AMeV and 8 AMeV were stored to collide with a windowless hydrogen target. The $^{125}$Cs reaction products were directly detected. The interaction energies are located on the high energy tail of the Gamow window for hot, explosive scenarios such as supernovae and X-ray binaries. The results serve as an important test of predicted astrophysical reaction rates in this mass range. Good agreement in the prediction of the astrophysically important proton width at low energy is found, with only a 30% difference between measurement and theory. Larger deviations are found above the neutron emission threshold, where also neutron- and $γ$-widths significantly impact the cross sections. The newly established experimental method is a very powerful tool to investigate nuclear reactions on rare ion beams at low center-of-mass energies.

nucl-ex↗

The thermal neutron capture cross section of the radioactive isotope $^{60}$Fe

50% of the heavy element abundances are produced via slow neutron capture reactions in different stellar scenarios. The underlying nucleosynthesis models need the input of neutron capture cross sections. One of the fundamental signatures for active nucleosynthesis in our galaxy is the observation of long-lived radioactive isotopes, such as $^{60}$Fe with a half-life of $2.60\times10^6$ yr. To reproduce this $γ$-activity in the universe, the nucleosynthesis of $^{60}$Fe has to be understood reliably. A $^{60}$Fe sample produced at the Paul-Scherrer-Institut was activated with thermal and epithermal neutrons at the research reactor at the Johannes Gutenberg-Universität Mainz. The thermal neutron capture cross section has been measured for the first time to $σ_{\text{th}}=0.226 \ (^{+0.044}_{-0.049})$ b. An upper limit of $σ_{\text{RI}} < 0.50$ b could be determined for the resonance integral. An extrapolation towards the astrophysicaly interesting energy regime between $kT$=10 keV and 100 keV illustrates that the s-wave part of the direct capture component can be neglected.

nucl-ex↗