SearcharxivSearch

arXiv subjects

Z. Slavkovska

Publications and source records attributed to Z. Slavkovska.

4 recordsLinked to original sources

Measurement of the cosmic muon flux at the Stawell Underground Physics Laboratory

We report the first measurement of the underground cosmic muon flux at the Stawell Underground Physics Laboratory. The measurement uses eight EJ200 plastic scintillator panels, equipped with Hamamatsu R13089 PMT pairs at the ends, which are the primary components of the muon veto system for the upcoming SABRE South experiment. The measured muon flux is f = (6.33 +/- 0.04_stat +/- 0.35_sys) x 10^{-8} [s^{-1} cm^{-2}]. This measurement is in excellent agreement with simulations, with a relative uncertainty an order of magnitude smaller than the modelling uncertainty.

hep-ex

Characterisation of Hamamatsu R11065-20 PMTs for use in the SABRE South NaI(Tl) Crystal Detectors

The SABRE Experiment is a direct detection dark matter experiment using a target composed of multiple NaI(Tl) crystals. The experiment aims to be an independent check of the DAMA/LIBRA results with a detector in the Northern (Laboratori Nazionali Del Gran Sasso, LNGS) and Southern (Stawell Underground Physics Laboratory, SUPL) hemispheres. The SABRE South photomultiplier tubes (PMTs) will be used near the low energy noise threshold and require a detailed calibration of their performance and contributions to the background in the NaI(Tl) dark matter search, prior to installation. We present the development of the pre-calibration procedures for the R11065-20 Hamamatsu PMTs. These PMTs are directly coupled to the NaI(Tl) crystals within the SABRE South experiment. In this paper we present methodologies to characterise the gain, dark rate, and timing properties of the PMTs. We develop a method for in-situ calibration without a light injection source. Additionally we explore the application of machine learning techniques using a Boosted Decision Tree (BDT) trained on the response of single PMTs to understand the information available for background rejection. Finally, we briefly present the simulation tool used to generate digitised PMT data from optical Monte Carlo simulations.

physics.ins-det

The DAMA/LIBRA signal: an induced modulation effect?

The persistence of the DAMA/LIBRA (DAMA) modulation over the past two decades has been a source of great contention within the dark matter community. The DAMA collaboration reports a persistent, modulating event rate within their setup of NaI(Tl) scintillating crystals at the INFN Laboratori Nazionali del Gran Sasso (LNGS) underground laboratory. A recent work alluded that this signal could have arisen due to an analysis artefact, caused by DAMA not accounting for time variation of decaying background radioisotopes in their analysis procedure. In this work, we examine in detail this 'induced modulation' effect, arguing that a number of aspects of the DAMA signal are incompatible with an induced modulation arising from decays of background isotopes over the lifetime of the experiment. Using a toy model of the DAMA/LIBRA experiment, we explore the induced modulation effect under different variations of the activities of the relevant isotopes - namely, $^3$H and $^{210}$Pb - highlighting the various inconsistencies between the resultant toy datasets and the DAMA signal. We stress the importance of the SABRE experiment, whose goal is to unambiguously test for the presence of such a modulating signal in an experiment using the same target material and comparable levels of background.

hep-ex

Determination of luminosity for in-ring reactions: A new approach for the low-energy domain

Luminosity is a measure of the colliding frequency between beam and target and it is a crucial parameter for the measurement of absolute values, such as reaction cross sections. In this paper, we make use of experimental data from the ESR storage ring to demonstrate that the luminosity can be precisely determined by modelling the measured Rutherford scattering distribution. The obtained results are in good agreement with an independent measurement based on the x-ray normalization method. Our new method provides an alternative way to precisely measure the luminosity in low-energy stored-beam configurations. This can be of great value in particular in dedicated low-energy storage rings where established methods are difficult or impossible to apply.

nucl-ex