Where is the Boundary: Multimodal Sensor Fusion Test Bench for Tissue Boundary Delineation

Robot-assisted neurological surgery is receiving growing interest due to the improved dexterity, precision, and control of surgical tools, which results in better patient outcomes. However, such systems often limit surgeons' natural sensory feedback, which is crucial in identifying tissues -- particularly in oncological procedures where distinguishing between healthy and tumorous tissue is vital. While imaging and force sensing have addressed the lack of sensory feedback, limited research has explored multimodal sensing options for accurate tissue boundary delineation. We present a user-friendly, modular test bench designed to evaluate and integrate complementary multimodal sensors for tissue identification. Our proposed system first uses vision-based guidance to estimate boundary locations with visual cues, which are then refined using data acquired by contact microphones and a force sensor. Real-time data acquisition and visualization are supported via an interactive graphical interface. Experimental results demonstrate that multimodal fusion significantly improves material classification accuracy. The platform provides a scalable hardware-software solution for exploring sensor fusion in surgical applications and demonstrates the potential of multimodal approaches in real-time tissue boundary delineation.

eess.SP

Design and Evaluation of a Compliant Quasi Direct Drive End-effector for Safe Robotic Ultrasound Imaging

Robot-assisted ultrasound scanning promises to advance autonomous and accessible medical imaging. However, ensuring patient safety and compliant human-robot interaction during probe contact poses a significant challenge. Most existing systems either have high mechanical stiffness or trade performance for compliance. This paper presents a novel compliant end-effector designed to mount on robotic arms for safe and accurate robotic ultrasound imaging, using a quasi-direct drive actuator to achieve passive mechanical compliance and precise active force control. To evaluate the end-effector's performance, we developed an ex vivo dynamic motion simulator platform for contact and scanning testing on tissue under simulated movements. The end-effector was evaluated against a UR3e robot arm using conventional force control strategies as a baseline. Single-point contact experiments from 2.5 N to 15 N show that the end-effector reduced force tracking RMS error by 80.1% on average. Trajectory scanning experiments at different speeds showed an average of 68.0% reduction in force tracking error. Statistically significant improvements were observed in four of six quantitative image quality and stability metrics using the end-effector. This work presents a novel approach for designing and evaluating compliant end-effectors, with the goal of improving safety and reliability in robotic ultrasound.

cs.RO