SearcharxivSearch

arXiv subjects

Zekun Zhao

Publications and source records attributed to Zekun Zhao.

10 recordsLinked to original sources

Enhancing Phase Estimation in a Hybrid Interferometer via Kerr Nonlinearity and Photon Subtraction

We propose a high-precision phase estimation scheme in a hybrid interferometer by synergistically combining a Kerr nonlinear phase shifter and multi-photon subtraction operations. Using a coherent state and a vacuum state as input resources, we systematically evaluate the phase sensitivity via homodyne detection and analyze the quantum Fisher information as well as the quantum Cramér-Rao bound under both ideal and lossy conditions. Our results show that the joint integration of Kerr nonlinearity and multi-photon subtraction yields remarkable advantages over either technique used alone. The proposed scheme enables the phase sensitivity to surpass the standard quantum limit, exceed the conventional Heisenberg scaling ($1/N$), and approach the super-Heisenberg scaling ($1/N^{2}$)-a direct consequence of Kerr nonlinearity. More precisely, the super-Heisenberg scaling $\propto $ $1/N^{2}$ is the ultimate precision limit permitted by the $k=2$ Kerr nonlinearity and does not violate the fundamental Heisenberg limit for linear phase accumulation. Even under moderate internal photon loss, the system maintains high precision and exhibits enhanced robustness to decoherence. The Kerr nonlinearity introduces an intensity-dependent phase shift proportional to the squared photon number, while multi-photon subtraction tailors non-Gaussian states to strengthen phase information extraction. Compared with existing schemes based on hybrid interferometers or SU(1,1) interferometers, our architecture achieves superior precision and stronger loss resilience. All components are experimentally accessible with current quantum optical technologies. This work provides a promising route for practical high-precision quantum metrology and quantum sensing.

quant-ph

Enhanced Phase Estimation via Photon-Added Two-Mode Squeezed States and Kerr Nonlinearity

Quantum metrology employs quantum resources to achieve measurement precision beyond classical limits. This work investigates a Mach--Zehnder interferometer incorporating a Kerr nonlinear phase shifter, with photon-added two-mode squeezed coherent states generated via four-wave mixing as input. We demonstrate that increasing both the photon-addition order and the input resource strength systematically enhances phase sensitivity, quantum Fisher information, and the corresponding quantum Cramér--Rao bound. The proposed system not only surpasses the standard quantum limit but also approaches or exceeds the Heisenberg limit for linear phase shifts, while Kerr nonlinearity enables surpassing the super-Heisenberg limit. Furthermore, the scheme exhibits enhanced robustness against photon loss, providing a promising pathway toward practical high-precision quantum metrology applications.

quant-ph

Two-parameter estimation via photon subtraction operation within a feedback-assisted interferometer

In this paper, we analyze how multi-photon subtraction operations in a feedback-assisted interferometer can enhance measurement precision for single-parameter and two-parameter estimation under both ideal and photon-loss conditions. We examine the effects of the feedback strength R, the optical parametric amplifier's gain g, the coherent state amplitude α, and the order of multi-photon subtraction on system performance. We demonstrate that an optimal feedback strength R_{opt} exists in both conditions. Selecting a suitable R can significantly boost the system's robustness to photon loss, and markedly improve measurement precision. And the photon subtraction operations within a feedback-assisted interferometer can further enhance measurement precision effectively. Additionally, we find that increasing intramode correlations while decreasing intermode correlations can improve estimation accuracy. This work investigates a new method through the synergistic integration of feedback topology and non-Gaussian operations into a multiparameter estimation system, along with their systematic study under both ideal and loss conditions. The findings may contribute to improving quantum-enhanced measurements and hold promise for high-precision quantum sensing research.

quant-ph

Improved linear and Kerr nonlinear phase estimation via photon addition operations

The accuracy of quantum measurements can be effectively improved by using both photon-added non-Gaussian operations and Kerr nonlinear phase shifters. Here, we employ coherent state mixed photon-added squeezed vacuum state as input into a Mach-Zehnder interferometer with parity detection, thereby achieving a significant enhancement in phase measurement accuracy. Our research focuses on phase sensitivity of linear phase shift under both ideal conditions and photon loss, as well as quantum Fisher information. The results demonstrate that employing the photon addition operations can markedly enhance phase sensitivity and quantum Fisher information, and the measurement accuracy can even approach the Heisenberg limit. In addition, we delve deeper into the scenario of replacing the linear phase shifter with a Kerr nonlinear one and systematically analyze the quantum Fisher information under both ideal and photon loss conditions. By comparison, it is evident that employing both the photon addition operations and the Kerr nonlinear phase shifter can further significantly enhance phase measurement accuracy while effectively improving the system's robustness against photon loss. These findings are instrumental in facilitating the development and practical application of quantum metrology.

quant-ph

Phase sensitivity via photon-subtraction operations inside Mach-Zehnder interferometer

Based on the conventional Mach-Zehnder interferometer, we propose a metrological scheme to improve phase sensitivity. In this scheme, we use a coherent state and a squeezed vacuum state as input states, employ multi-photon-subtraction operations and make intensity-detection or homodyne-detection. We study phase sensitivity, quantum Fisher information and quantum Cramér-Rao bound under both ideal and lossy conditions. The results indicate that choosing an appropriate detection method and photon subtraction scheme can significantly enhance the phase sensitivity and robustness against photon losses. Even under lossy conditions, the multi-photon subtraction schemes can surpass the standard quantum limit. Notably, the homodyne detection method can even break through the Heisenberg limit. Moreover, increasing the number of photon-subtracted can enhance both phase sensitivity and quantum Fisher information. This research highlights the significant value of this scheme in quantum precision measurement.

quant-ph

Improved phase sensitivity of an SU(1,1) interferometer based on the internal single-path local squeezing operation

Compared to passive interferometers, SU(1,1) interferometers exhibit superior phase sensitivity due to the incorporation of nonlinear elements that enhance their ability to detect phase shifts. However, the precision of these interferometers is significantly affected by photon losses, especially internal losses, which can limit the overall measurement accuracy. Addressing these issues is essential to fully realize the advantages of SU(1,1) interferometers in practical applications. Among the known resources of quantum metrology, one of the most practical and efficient is squeezing. We propose a theoretical scheme to improve the precision of phase measurement using homodyne detection by implementing the single-path local squeezing operation (LSO) inside the SU(1,1) interferometer, with the coherent state and the vacuum state as the input states. We not only analyze the effects of the single-path LSO scheme on the phase sensitivity and the quantum Fisher information (QFI) under both ideal and photon-loss cases but also compare the effects of different squeezing parameters r on the system performance. Our findings reveal that the internal single-path LSO scheme can enhance the phase sensitivity and the QFI, effectively improving the robustness of the SU(1,1) interferometer against internal and external photon losses. Additionally, a larger squeezing parameter r leads to a better performance of the interferometer.

quant-ph

Phase sensitivity for an SU(1,1) interferometer via multiphoton subtraction at the output port

In the field of quantum precision measurement, enhancing phase sensitivity is crucial for various applications, including quantum metrology and quantum sensing technologies. We theoretically investigate the improvement in phase sensitivity and quantum Fisher information achieved through multiphoton subtraction operations at the output port of an SU(1,1) interferometer under conditions of photon loss. We use vacuum and coherent states as the inputs and detect the outputs by intensity detection. The results indicate that internal photon losses within the SU(1,1) interferometer have a more significant impact on the phase sensitivity compared to external photon losses. Moreover, increasing the number of photon subtractions m effectively enhances both the phase sensitivity and the quantum Fisher information. Notably, even under conditions of severe photon loss, the multiphoton subtraction operations can enable the phase sensitivity to surpass the standard quantum limit, approaching both the Heisenberg limit and the quantum Cramér-Rao bound. This study provides a new theoretical basis for enhancing the phase sensitivity in the SU(1,1) interferometer.

quant-ph

Phase estimation via number-conserving operation inside the SU(1,1) interferometer

Utilizing nonlinear elements, SU(1,1) interferometers demonstrate superior phase sensitivity compared to passive interferometers. However, the precision is significantly impacted by photon losses, particularly internal losses. We propose a theoretical scheme to improve the precision of phase measurement using homodyne detection by implementing number-conserving operations (PA-then-PS and PS-then-PA) within the SU(1,1) interferometer, with the coherent state and the vacuum state as the input states. We analyze the effects of number-conserving operations on the phase sensitivity, the quantum Fisher information, and the quantum Cramer-Rao bound under both ideal and photon losses scenarios. Our findings reveal that the internal non-Gaussian operations can enhance the phase sensitivity and the quantum Fisher information, and effectively improve the robustness of the SU(1,1) interferometer against internal photon losses. Notably, the PS-then-PA scheme exhibits superior improvement in both ideal and photon losses cases in terms of phase sensitivity. Moreover, in the ideal case, PA-then-PS scheme slightly outperforms PS-then-PA scheme in terms of the quantum Fisher information and the Quantum Cramer-Rao. However, in the presence of photon losses, PS-then-PA scheme demonstrates a greater advantage.

quant-ph

Phase estimation via coherent and photon-catalyzed squeezed vacuum states

The research focused on enhancing the measurement accuracy through the use of non-Gaussian states has garnered increasing attention. In this study, we propose a scheme to input the coherent state mixed with photon-catalyzed squeezed vacuum state into the Mach-Zender interferometer to enhance phase measurement accuracy. The findings demonstrate that photon catalysis, particularly multi-photon catalysis, can effectively improve the phase sensitivity of parity detection and the quantum Fisher information. Moreover, the situation of photon losses in practical measurement was studied. The results indicate that external dissipation has a greater influence on phase sensitivity than the internal dissipation. Compared to input coherent state mixed with squeezed vacuum state, the utilization of coherent state mixed photon-catalyzed squeezed vacuum state, particularly the mixed multi-photon catalyzed squeezed vacuum state as input, can enhance the phase sensitivity and quantum Fisher information. Furthermore, the phase measurement accuracy can exceed the standard quantum limit, and even surpass the Heisenberg limit. This research is expected to significantly contribute to quantum precision measurement.

quant-ph

Phase estimation of Mach-Zehnder interferometer via Laguerre excitation squeezed state

Quantum metrology has an important role in the fields of quantum optics and quantum information processing. Here we introduce a kind of non-Gaussian state, Laguerre excitation squeezed state as input of traditional Mach-Zehnder interferometer to examine phase estimation in realistic case. We consider the effects of both internal and external losses on phase estimation by using quantum Fisher information and parity detection. It is shown that the external loss presents a bigger effect than the internal one. The phase sensitivity and the quantum Fisher information can be improved by increasing the photon number and even surpass the ideal phase sensitivity by two-mode squeezed vacuum in a certain region of phase shift for realistic case.

quant-ph