SearcharxivSearch

arXiv subjects

Zenith Purisha

Publications and source records attributed to Zenith Purisha.

10 recordsLinked to original sources

Non-Stationary Multi-layered Gaussian Priors for Bayesian Inversion

In this article, we study Bayesian inverse problems with multi-layered Gaussian priors. We first describe the conditionally Gaussian layers in terms of a system of stochastic partial differential equations. We build the computational inference method using a finite-dimensional Galerkin method. We show that the proposed approximation has a convergence-in-probability property to the solution of the original multi-layered model. We then carry out Bayesian inference using the preconditioned Crank--Nicolson algorithm which is modified to work with multi-layered Gaussian fields. We show via numerical experiments in signal deconvolution and computerized X-ray tomography problems that the proposed method can offer both smoothing and edge preservation at the same time.

math.ST

Dynamic 3D Tomographic X-ray Data of Ladybug

This is the documentation of the 3D dynamic tomographic X-ray (CT) data of a ladybug. The open data set is available https://zenodo.org/record/3375488#.XV_T3vxS9oA and can be freely used for scientific purposes with appropriate references to the data and to this document in http://arxiv.org/

physics.med-ph

CT Data of a Pen-Spring: Application to Under-Sampled Dynamic X-ray Tomography

This is the documentation of Computed Tomography (CT) data of a pen-spring. The open data set is available at https://zenodo.org/record/3266936#.XRyMdCZS9oA and can be freely used for scientific purposes with appropriate references to the data and to this document in arxiv.org. The provided data set includes the X-ray sinograms ({\tt finalSino}) of a single 2D slice from a different height of the spring. The {\tt finalSino} was obtained from a measured 10-projection or 100-projection {\tt sinogram} using fan-beam geometry by down-sampling and taking logarithms. The data set includes also those original measured {\tt sinogram}s and corresponding measurement matrices.

physics.med-ph

Probabilistic approach to limited-data computed tomography reconstruction

In this work, we consider the inverse problem of reconstructing the internal structure of an object from limited x-ray projections. We use a Gaussian process prior to model the target function and estimate its (hyper)parameters from measured data. In contrast to other established methods, this comes with the advantage of not requiring any manual parameter tuning, which usually arises in classical regularization strategies. Our method uses a basis function expansion technique for the Gaussian process which significantly reduces the computational complexity and avoids the need for numerical integration. The approach also allows for reformulation of come classical regularization methods as Laplacian and Tikhonov regularization as Gaussian process regression, and hence provides an efficient algorithm and principled means for their parameter tuning. Results from simulated and real data indicate that this approach is less sensitive to streak artifacts as compared to the commonly used method of filtered backprojection.

cs.CV

Undersampled dynamic X-ray tomography with dimension reduction Kalman filter

In this paper, we consider prior-based dimension reduction Kalman filter for undersampled dynamic X-ray tomography. With this method, the X-ray reconstructions are parameterized by a low-dimensional basis. Thus, the proposed method is a) computationally very light; and b) extremely robust as all the computations can be done explicitly. With real and simulated measurement data, we show that the method provides accurate reconstructions even with very limited number of angular directions.

stat.CO

Tomographic X-ray data of 3D emoji

This is the documentation of the tomographic X-ray data of emoji phantom made available at https://zenodo.org/record/1183532#.WpA35Y5rIy1. The data can be freely used for scientific purposes with appropriate references to the data and to this document in arxiv.org. The data set consists of (1) the X-ray sinogram of a single 2D slice of 33 emoji faces (contains 15 different emoji faces) made by small squared ceramic stones and (2) the corresponding static and dynamic measurement matrices modeling the linear operation of the X-ray transform. Each of these sinograms was obtained from a measured 60-projection fan-beam sinogram by down-sampling and taking logarithms. The original (measured) sinogram is also provided in its original form and resolution. The original (measured) sinogram is also provided in its original form and resolution.

physics.med-ph

An automatic regularization method: An application for 3D X-ray micro-CT reconstruction using sparse data

X-ray tomography is a reliable tool for determining the inner structure of 3D object with penetrating X-rays. However, traditional reconstruction methods such as FDK require dense angular sampling in the data acquisition phase leading to long measurement times, especially in X-ray micro-tomography to obtain high resolution scans. Acquiring less data using greater angular steps is an obvious way for speeding up the process and avoiding the need to save huge data sets available memory. However, computing 3D reconstruction from such a sparsely sampled dataset is very sensitive to measurement noise and modelling errors. An automatic regularization method is proposed for robust reconstruction, based on enforcing sparsity in the three-dimensional shearlet transform domain. The inputs of the algorithm are the projection data and {\it a priori} known expected degree of sparsity, denoted $0<{\mathcal C}_{pr}\leq 1$. The number ${\mathcal C}_{pr}$ can be calibrated from a few dense-angle reconstructions and fixed. Human subchondral bone samples were tested and morphometric parameters of the bone reconstructions were then analyzed using standard metrics. The proposed method is shown to outperform the baseline algorithm (FDK) in the case of sparsely collected data. The number of X-ray projections can be reduced up to 10\% of the total amount while retaining the quality of the reconstruction images and of the morphometric paramaters.

physics.med-ph

Tomographic X-ray data of carved cheese

This is the documentation of the tomographic X-ray data of a carved cheese slice. Data are available at www.fips.fi/dataset.php, and can be freely used for scientific purposes with appropriate references to them, and to this document in http://arxiv.org/. The data set consists of (1) the X-ray sinogram of a single 2D slice of the cheese slice with three different resolutions and (2) the corresponding measurement matrices modeling the linear operation of the X-ray transform. Each of these sinograms was obtained from a measured 360-projection fan-beam sinogram by down-sampling and taking logarithms. The original (measured) sinogram is also provided in its original form and resolution.

physics.med-ph

Controlled Wavelet Domain Sparsity in X-ray Tomography

Tomographic reconstruction is an ill-posed inverse problem that calls for regularization. One possibility is to require sparsity of the unknown in an orthonormal wavelet basis. This in turn can be achieved by variational regularization where the penalty term is the sum of absolute values of wavelet coefficients. Daubechies, Defrise and De Mol (Comm. Pure Appl. Math. 57) showed that the minimizer of the variational regularization functional can be computed iteratively using a soft thresholding operation. Choosing the soft threshold parameter $\mu>0$ is analogous to the notoriously difficult problem of picking the optimal regularization parameter in Tikhonov regularization. Here a novel automatic method is introduced for choosing $\mu$, based on a control algorithm driving the sparsity of the reconstruction to an {\it a priori} known ratio of nonzero versus zero wavelet coefficients in the unknown function.

math.NA

Shape recovery from sparse tomographic X-ray data

A two-dimensional tomographic problem is studied. The target is assumed to be a homogeneous object bounded by a smooth curve. A Non Uniform Rational Basis Splines (NURBS) curve is used as computational representation of the boundary. This approach conveniently provides the result in a format readily compatible with computer-aided design (CAD) software. However, the linear tomography task becomes a nonlinear inverse problem due to the NURBS-based parameterization. Therefore, Bayesian inversion with Markov chain Monte Carlo (MCMC) sampling is used for calculating an estimate of the NURBS control points. The reconstruction method is tested with both simulated data and measured X-ray projection data. The proposed method recovers the shape and the attenuation coefficient significantly better than the baseline algorithm (optimally thresholded total variation regularization), but at the cost of heavier computation.

math.NA