SearcharxivSearch

arXiv subjects

Zhangyan Li

Publications and source records attributed to Zhangyan Li.

2 recordsLinked to original sources

Physics-guided residual correction of $\alpha$-decay half-lives based on the effective liquid drop model

To improve the prediction accuracy of $\alpha$-decay half-lives in heavy and superheavy nuclei, a physics-guided residual-correction framework combining the effective liquid drop model (ELDM) with machine-learning methods is proposed. The ELDM is first used as the macroscopic baseline for describing the barrier-penetration process, and XGBoost and TabPFN models are then employed to learn the residual deviations between ELDM predictions and experimental data. To incorporate microscopic nuclear-structure information, several physically motivated descriptors are constructed, including deformation-related quantities, Geiger--Nuttall-related features, and minimum orbital angular momentum. The results show that machine-learning residual correction significantly improves the predictive performance of the ELDM baseline. Among all models, TabPFN-term3 achieves the best accuracy, reducing the RMSE and MAE to 0.348 and 0.248, corresponding to improvements of 38.60\% and 40.46\%, respectively. Residual-distribution and feature-ablation analyses further indicate that the corrected predictions are closer to experimental values and that physically motivated descriptors play an important role in learning nonlinear residual structures. Overall, the proposed ELDM-based residual-correction framework can effectively compensate for missing microscopic nuclear-structure effects while preserving physical interpretability, providing a feasible strategy for high-precision $\alpha$-decay half-life prediction.

nucl-th

Ultrasensitive refractive index sensor with rotatory biased weak measurement

A modified weak measurement scheme, rotatory biased weak measurement, is proposed to significantly improve the sensitivity and resolution of the refractive index sensor on a total reflection structure. This method introduces an additional phase in the post-selected procedure and generates an extinction point in the spectrum distribution. The biased post-selection makes smaller coupling strength available, which leads to an enhancement of phase sensitivity and refractive index sensitivity. In rotatory biased weak measurement, we achieve an enhanced refractive index sensitivity of 13605 nm/RIU compared to 1644 nm/RIU in standard weak measurement. The performance of sensors with different sensitivity is analyzed, and we find the optimal refractive index resolution of sensors increases with sensitivity. In this work, we demonstrate an optimal refractive index resolution of $4\times10^{-7}$ RIU on a total reflection structure. The rabbit anti-mouse IgG and mouse IgG binding reaction experiments demonstrate that our system has a high response to the concentration of IgG in a wide range and the limit of detection is 15 ng/mL. The improvements in this work are helpful to the optimizations of other optical sensors with weak measurement.

quant-ph