SearcharxivSearch

arXiv subjects

Zhengguo Tan

Publications and source records attributed to Zhengguo Tan.

6 recordsLinked to original sources

Rapid, High-resolution and Distortion-free $R_{2}^{*}$ Mapping of Fetal Brain using Multi-echo Radial FLASH and Model-based Reconstruction

Purpose: To develop a rapid, high-resolution and distortion-free technique for simultaneous water-fat separation, $R_{2}^{*}$ and $B_{0}$ mapping of the fetal brain at 3T. Methods: A 2D multi-echo radial FLASH sequence with blip gradients is adapted for data acquisition during maternal free breathing. A calibrationless model-based reconstruction with sparsity constraints is developed to jointly estimate water, fat, $R_{2}^{*}$ and $B_{0}$ field maps directly from k-space. This approach was validated and compared to reference methods using numerical and NIST phantoms and data from nine fetuses between 26 and 36 weeks of gestation age. Results: Both numerical and experimental phantom studies confirm good accuracy and precision. In fetal studies, model-based reconstruction yields quantitative $R_{2}^{*}$ values in close agreement with those from a parallel imaging compressed sensing (PICS) technique using Graph Cut (intra-class correlation coefficient [ICC] = 0.9601), while providing enhanced image detail. Repeated scans confirm good reproducibility (ICC = 0.9213). Compared to multi-echo EPI, the proposed radial technique produces higher-resolution (1.1 $\times$ 1.1 $\times$ 3 mm$^{3}$ vs. 2-3 $\times$ 2-3 $\times$ 3 mm$^{3}$) $R_{2}^{*}$ maps with reduced distortion. Despite of differences in motion, resolution and distortion, $R_{2}^{*}$ values are comparable between the two acquisition strategies (ICC = 0.8049). Additionally, the proposed approach enables synthesis of high-resolution and distortion-free $R_{2}^{*}$-weighted images. Conclusion: This study demonstrates the feasibility of using multi-echo radial FLASH combined with calibrationless model-based reconstruction for motion-robust, distortion-free $R_{2}^{*}$ mapping of the fetal brain at 3T, achieving a nominal resolution of $1.1 \times 1.1 \times 3$ mm$^{3}$ within 2 seconds per slice.

physics.med-ph

fastMRI Breast: A publicly available radial k-space dataset of breast dynamic contrast-enhanced MRI

This data curation work introduces the first large-scale dataset of radial k-space and DICOM data for breast DCE-MRI acquired in diagnostic breast MRI exams. Our dataset includes case-level labels indicating patient age, menopause status, lesion status (negative, benign, and malignant), and lesion type for each case. The public availability of this dataset and accompanying reconstruction code will support research and development of fast and quantitative breast image reconstruction and machine learning methods.

physics.med-ph

Model-Based Reconstruction for Joint Estimation of $T_{1}$, $R_{2}^{*}$ and $B_{0}$ Field Maps Using Single-Shot Inversion-Recovery Multi-Echo Radial FLASH

Purpose: To develop a model-based nonlinear reconstruction for simultaneous water-specific $T_{1}$, $R_{2}^{*}$, $B_{0}$ field and/or fat fraction (FF) mapping using single-shot inversion-recovery (IR) multi-echo radial FLASH. Methods: The proposed model-based reconstruction jointly estimates water-specific $T_{1}$, $R_{2}^{*}$, $B_{0}$ field and/or FF maps, as well as a set of coil sensitivities directly from $k$-space obtained with a single-shot IR multi-echo radial FLASH sequence using blip gradients across echoes. Joint sparsity constraints are exploited on multiple quantitative maps to improve precision. Validations are performed on numerical and NIST phantoms and with in vivo studies of the human brain and liver at 3 T. Results: Numerical phantom studies demonstrate the effects of fat signals in $T_{1}$ estimation and confirm good quantitative accuracy of the proposed method for all parameter maps. NIST phantom results confirm good quantitative $T_{1}$ and $R_{2}^{*}$ accuracy in comparison to Cartesian references. Apart from good quantitative accuracy and precision for multiple parameter maps, in vivo studies show improved image details utilizing the proposed joint estimation. The proposed method can achieve simultaneous water-specific $T_{1}$, $R_{2}^{*}$, $B_{0}$ field and/or FF mapping for brain (0.81 $\times$ 0.81 $\times$ 5 mm$^{3}$) and liver (1.6 $\times$ 1.6 $\times$ 6 mm$^{3}$) imaging within four seconds. Conclusion: The proposed model-based nonlinear reconstruction, in combination with a single-shot IR multi-echo radial FLASH acquisition, enables joint estimation of accurate water-specific $T_{1}$, $R_{2}^{*}$, $B_{0}$ field and/or FF maps within four seconds. The present work is of potential value for specific clinical applications.

physics.med-ph

Free-Breathing Myocardial T1 Mapping using Inversion-Recovery Radial FLASH and Motion-Resolved Model-Based Reconstruction

Purpose: To develop a free-breathing myocardial T1 mapping technique using inversion-recovery (IR) radial fast low-angle shot (FLASH) and calibrationless motion-resolved model-based reconstruction. Methods: Free-running (free-breathing, retrospective cardiac gating) IR radial FLASH is used for data acquisition at 3T. First, to reduce the waiting time between inversions, an analytical formula is derived that takes the incomplete T1 recovery into account for an accurate T1 calculation. Second, the respiratory motion signal is estimated from the k-space center of the contrast varying acquisition using an adapted singular spectrum analysis (SSA-FARY) technique. Third, a motion-resolved model-based reconstruction is used to estimate both parameter and coil sensitivity maps directly from the sorted k-space data. Thus, spatiotemporal total variation, in addition to the spatial sparsity constraints, can be directly applied to the parameter maps. Validations are performed on an experimental phantom, eleven human subjects, and a young landrace pig with myocardial infarction. Results: In comparison to an IR spin-echo reference, phantom results confirm good T1 accuracy when reducing the waiting time from five seconds to one second using the new correction. The motion-resolved model-based reconstruction further improves precision compared to the spatial regularization-only reconstruction. Aside from showing that a reliable respiratory motion signal can be estimated using modified SSA-FARY, in vivo studies demonstrate that dynamic myocardial T1 maps can be obtained within two minutes with good precision and repeatability. Conclusion: Motion-resolved myocardial T1 mapping during free-breathing with good accuracy, precision and repeatability can be achieved by combining inversion-recovery radial FLASH, self-gating and a calibrationless motion-resolved model-based reconstruction.

physics.med-ph

Free-Breathing Liver Fat, $R_2^*$ and $B_0$ Field Mapping Using Multi-Echo Radial FLASH and Regularized Model-based Reconstruction

This work introduced a stack-of-radial multi-echo asymmetric-echo MRI sequence for free-breathing liver volumetric acquisition. Regularized model-based reconstruction was implemented in Berkeley Advanced Reconstruction Toolbox (BART) to jointly estimate all physical parameter maps (water, fat, R2*, and B0 field inhomogeneity maps) and coil sensitivity maps from self-gated k-space data. Specifically, locally low rank and temporal total variation regularization were employed directly on physical parameter maps. The proposed free-breathing radial technique was tested on a water/fat & iron phantom, a young volunteer, and obesity/diabetes/hepatic steatosis patients. Quantitative fat fraction and R2* accuracy were confirmed by comparing our technique with the reference breath-hold Cartesian scan. The multi-echo radial sampling sequence achieves fast k-space coverage and is robust to motion. Moreover, the proposed motion-resolved model-based reconstruction allows for free-breathing liver fat and R2* quantification in multiple motion states. Overall, our proposed technique offers a convenient tool for non-invasive liver assessment with no breath holding requirement.

physics.med-ph

Physics-based Reconstruction Methods for Magnetic Resonance Imaging

Conventional Magnetic Resonance Imaging (MRI) is hampered by long scan times and only qualitative image contrasts that prohibit a direct comparison between different systems. To address these limitations, model-based reconstructions explicitly model the physical laws that govern the MRI signal generation. By formulating image reconstruction as an inverse problem, quantitative maps of the underlying physical parameters can then be extracted directly from efficiently acquired k-space signals without intermediate image reconstruction -- addressing both shortcomings of conventional MRI at the same time. This review will discuss basic concepts of model-based reconstructions and report about our experience in developing several model-based methods over the last decade using selected examples that are provided complete with data and code.

eess.IV