Zhentian Wang

Publications and source records attributed to Zhentian Wang.

4 recordsLinked to original sources

Coupling Spectrum Estimation and Single Energy Material Decomposition via X-ray Grating Interferometry

Dark-field imaging based on grating interferometry is an emerging X-ray modality in medical imaging, which is particularly capable of providing complementary diagnostic information by visualizing the microstructural properties of lung tissue. However, quantitative dark-field imaging remains fundamentally challenged by beam hardening, which arises from the energy-dependent fringe visibility under polychromatic illumination. The resulting artifacts substantially degrade the quantitative accuracy of dark-field images. In this work, motivated by our key observation of an intrinsic similarity between the X-ray energy spectrum and the system-related coupling spectrum, we propose a unified framework to simultaneously and independently estimate both spectra. By measuring the transmission associated with the zeroth- and first-order components of the phase-stepping curve using solid step-wedge phantoms, the two spectra are robustly estimated via an expectation-maximization algorithm. The recovered spectra are subsequently incorporated into a physics-based correction model to mitigate beam-hardening-induced artifacts in dark-field imaging effectively. Furthermore, leveraging the inherent availability of two independent spectra within X-ray grating interferometry, we introduce a single-energy material decomposition method that achieves basis material imaging without dual-energy scans. Wave-optical simulations and experiments demonstrate accurate spectrum estimation, effective dark-field signal correction, and reliable material decomposition. Consequently, the proposed framework extends the diagnostic potential of X-ray grating interferometry beyond pulmonary imaging, facilitating broader applications in medical imaging.

physics.med-ph↗

Optimization of Dark-Field CT for Lung Imaging

Background: X-ray grating-based dark-field imaging can sense the small angle scattering caused by an object's micro-structure. This technique is sensitive to lung's porous alveoli and is able to detect lung disease at an early stage. Up to now, a human-scale dark-field CT has been built for lung imaging. Purpose: This study aimed to develop a more thorough optimization method for dark-field lung CT and summarize principles for system design. Methods: We proposed a metric in the form of contrast-to-noise ratio (CNR) for system parameter optimization, and designed a phantom with concentric circle shape to fit the task of lung disease detection. Finally, we developed the calculation method of the CNR metric, and analyzed the relation between CNR and system parameters. Results: We showed that with other parameters held constant, the CNR first increases and then decreases with the system auto-correlation length (ACL). The optimal ACL is nearly not influenced by system's visibility, and is only related to phantom's property, i.e., scattering material's size and phantom's absorption. For our phantom, the optimal ACL is about 0.21 μm. As for system geometry, larger source-detector and isocenter-detector distance can increase the system's maximal ACL, helping the system meet the optimal ACL more easily. Conclusions: This study proposed a more reasonable metric and a task-based process for optimization, and demonstrated that the system optimal ACL is only related to the phantom's property.

physics.med-ph↗

Refraction beats attenuation in breast CT

For a century, clinical X-ray imaging has visualised only the attenuation properties of tissue, which fundamentally limits the contrast, particularly in soft tissues like the breast. Imaging based on refraction can overcome this limitation, but so far has been constrained to high-dose ex-vivo applications or required highly coherent X-ray sources, like synchrotrons. It has been predicted that grating interferometry (GI) could eventually allow computed tomography (CT) to be more dose-efficient. However, the benefit of refraction in clinical CT has not been demonstrated so far. Here we show that GI-CT is more dose-efficient in imaging of breast tissue than conventional CT. Our system, based on a 70kVp X-ray tube source and commercially available gratings, demonstrated superior quality, in terms of adipose-to-glandular tissue contrast-to-noise ratio (CNR), of refraction-contrast compared to the attenuation images. The fusion of the two modes of contrast outperformed conventional CT for spatial resolutions better than 263μm and an average dose to the breast of 16mGy, which is in the clinical breast CT range. Our results show that grating interferometry can significantly reduce the dose, while maintaining the image quality, in diagnostic breast CT. Unlike conventional absorption-based CT, the sensitivity of refraction-based imaging is far from being fully exploited, and further progress will lead to significant improvements of clinical X-ray CT.

physics.med-ph↗

High aspect ratio silicon structures by Displacement Talbot lithography and Bosch etching

Despite the fact that the resolution of conventional contact/proximity lithography can reach feature sizes down to ~0.5-0.6 micrometers, the accurate control of the linewidth and uniformity becomes already very challenging for gratings with periods in the range of 1-2 μm. This is particularly relevant for the exposure of large areas and wafers thinner than 300μm. If the wafer or mask surface is not fully flat due to any kind of defects, such as bowing/warpage or remaining topography of the surface in case of overlay exposures, noticeable linewidth variations or complete failure of lithography step will occur. We utilized the newly developed Displacement Talbot lithography to pattern gratings with equal lines and spaces and periods in the range of 1.0 to 2.4 μm. The exposures in this lithography process do not require contact between the mask and the wafer, which makes it essentially insensitive to surface planarity and enables exposures with very high linewidth uniformity on thin and even slightly deformed wafers. We demonstrated pattern transfer of such exposures into Si substrates by reactive ion etching using the Bosch process. An etching depth of 30 μm or more for the whole range of periods was achieved, which corresponds to very high aspect ratios up to 60:1. The application of the fabricated gratings in phase contrast x-ray imaging is presented.

physics.app-ph↗