SearcharxivSearch

arXiv subjects

Zhewei Zhang

Publications and source records attributed to Zhewei Zhang.

6 recordsLinked to original sources

LIRA: Local Cross-Layer Information Routing for Vision-Language-Action Decoding

Vision-Language-Action (VLA) models transform representations from pretrained vision-language models (VLMs) into robot actions, yet the interface that routes intermediate VLM features into action decoders remains underexplored. Existing designs either expose only a narrow part of the representation hierarchy or rigidly match each decoder block to one VLM layer, restricting access to complementary task evidence across depths. We introduce LIRA, a local cross-layer action-conditioning mechanism that formulates VLM-to-action conditioning as depth-aware information routing. LIRA operates on task-token features and LIRA Query features derived from intermediate VLM states, then assigns each Parallel Fusion Block a depth-aligned local window centered on its corresponding VLM layer. Parallel Fusion Blocks aggregate neighboring LIRA Query features and integrate them with task-token features and proprioceptive inputs before action prediction. This routing interface leaves the backbone architecture, action decoder, and supervised training recipe unchanged. Across LIBERO, LIBERO-Plus, CALVIN ABC$\rightarrow$D, and real-world manipulation, LIRA improves the principal aggregate metrics over the VLA-Adapter baseline under the same 0.5B-parameter configuration. In zero-shot transfer to LIBERO-Plus, LIRA increases average success from 59.1% to 78.0%, an 18.9-point gain indicating improved robustness under controlled distribution shifts.

cs.RO

Improving the efficiency of infectious disease prevention trials using negative control outcome event times

Baseline covariate adjustment can enhance the efficiency of randomized trials by improving precision of treatment effect estimates. However, the precision gain depends on how strongly the baseline covariates are prognostic for the primary outcome. In randomized trials of infectious disease prevention interventions (e.g., vaccines or passively administered antibodies), an individual's exposure to the pathogen is a leading prognostic factor but is rarely measurable at baseline. Hence, conventional covariate adjustment offers limited precision gain in prevention trials. We propose adjusting for a negative control outcome (NCO) event time, which is causally unaffected by the intervention but shares overlapping exposure mechanisms with the primary outcome. We formalize assumptions under which adjustment for the NCO event time is valid, and show that right-censoring of the NCO event time further complicates adjustment. We derive the efficient influence function for the treatment-arm-specific survivor function of the primary outcome when both the primary outcome and the NCO event time are right-censored, and use it to construct a cross-fitted, one-step estimator that is multiply robust to nuisance misspecification and asymptotically efficient when the nuisances are estimated accurately. In numerical experiments, our estimator compares comparably to benchmarks when the NCO event time is uninformative, and gains precision as the NCO event time is more prognostic for the primary outcome. We apply our method to HVTN 704/HPTN 085, a randomized, double-blinded trial of VRC01, a broadly neutralizing antibody against HIV-1. Adjusting for the time to a bacterial sexually transmitted infection --- a negative control outcome for HIV-1 acquisition --- reduced the estimated variance of the prevention efficacy estimate by approximately 27%, compared to roughly 2.5% for baseline covariate adjustment.

stat.ME

Super doubly robust and efficient estimator for informative covariate censoring

Early intervention in neurodegenerative diseases requires identifying periods before diagnosis when decline is rapid enough to detect whether a therapy is slowing progression. Since rapid decline typically occurs close to diagnosis, identifying these periods requires knowing each patient's time of diagnosis. Yet many patients exit studies before diagnosis, making time of diagnosis right-censored by time of study exit -- creating a right-censored covariate problem when estimating decline. Existing estimators either assume noninformative covariate censoring, where time of study exit is independent of time of diagnosis, or allow informative covariate censoring, but require correctly specifying how these times are related. We developed SPIRE (Semi-Parametric Informative Right-censored covariate Estimator), a super doubly robust estimator that remains consistent without correctly specifying densities governing time of diagnosis or time of study exit. Typical double robustness requires at least one density to be correct; SPIRE requires neither. When both densities are correctly specified, SPIRE achieves semiparametric efficiency. We also developed a test for detecting informative covariate censoring. Simulations with 85% right-censoring demonstrated SPIRE's robustness, efficiency and reliable detection of informative covariate censoring. Applied to Huntington disease data, SPIRE handled informative covariate censoring appropriately and remained consistent regardless of density specification, providing a reliable tool for early intervention.

math.ST

FSG-Net: Frequency-Spatial Synergistic Gated Network for High-Resolution Remote Sensing Change Detection

Change detection from high-resolution remote sensing images lies as a cornerstone of Earth observation applications, yet its efficacy is often compromised by two critical challenges. First, false alarms are prevalent as models misinterpret radiometric variations from temporal shifts (e.g., illumination, season) as genuine changes. Second, a non-negligible semantic gap between deep abstract features and shallow detail-rich features tends to obstruct their effective fusion, culminating in poorly delineated boundaries. To step further in addressing these issues, we propose the Frequency-Spatial Synergistic Gated Network (FSG-Net), a novel paradigm that aims to systematically disentangle semantic changes from nuisance variations. Specifically, FSG-Net first operates in the frequency domain, where a Discrepancy-Aware Wavelet Interaction Module (DAWIM) adaptively mitigates pseudo-changes by discerningly processing different frequency components. Subsequently, the refined features are enhanced in the spatial domain by a Synergistic Temporal-Spatial Attention Module (STSAM), which amplifies the saliency of genuine change regions. To finally bridge the semantic gap, a Lightweight Gated Fusion Unit (LGFU) leverages high-level semantics to selectively gate and integrate crucial details from shallow layers. Comprehensive experiments on the CDD, GZ-CD, and LEVIR-CD benchmarks validate the superiority of FSG-Net, establishing a new state-of-the-art with F1-scores of 94.16%, 89.51%, and 91.27%, respectively. The code will be made available at https://github.com/zxXie-Air/FSG-Net after a possible publication.

cs.CV

Scalable Miniature On-chip Fourier Transform Spectrometer For Raman Spectroscopy

Miniaturized spectrometers for Raman spectroscopy have the potential to open up a new chapter in sensing. Raman spectroscopy is essential for material characterization and biomedical diagnostics, however, its weak signal and the need for sub-nanometer resolution pose challenges. Conventional spectrometers, with footprints proportional to optical throughput and resolution, are difficult to integrate into compact devices such as wearables. Waveguide-based Fourier Transform Spectrometers (FTS) enable compact spectrometers, and multi-aperture designs can achieve high throughput for applications such as Raman spectroscopy, however, experimental research in this domain remains limited. In this work, we present a multi-aperture SiN waveguide-based FTS overcoming these limitations and enabling Raman spectroscopy of isopropyl alcohol, glucose, Paracetamol, and Ibuprofen with enhanced throughput. Our spectrometer chip, fabricated on a 200 mm SiN wafer, with 160 edge-coupled waveguide apertures connected to an array of ultra-compact interferometers and a small footprint of just 1.6 mm x 4.8 mm, achieves a spectral range of 40 nm and a resolution of 0.5 nm. Experimental results demonstrate that least absolute shrinkage and selection operator (LASSO) regression significantly enhances Raman spectrum reconstruction. Our work on waveguide-based spectrometry paves the way for integrating accurate and compact Raman sensors into consumer electronics and space exploration instruments.

physics.optics

Vernier spectrometer using counter-propagating soliton microcombs

Acquisition of laser frequency with high resolution under continuous and abrupt tuning conditions is important for sensing, spectroscopy and communications. Here, a single microresonator provides rapid and broad-band measurement of frequencies across the optical C-band with a relative frequency precision comparable to conventional dual frequency comb systems. Dual-locked counter-propagating solitons having slightly different repetition rates are used to implement a Vernier spectrometer. Laser tuning rates as high as 10 THz/s, broadly step-tuned lasers, multi-line laser spectra and also molecular absorption lines are characterized using the device. Besides providing a considerable technical simplification through the dual-locked solitons and enhanced capability for measurement of arbitrarily tuned sources, this work reveals possibilities for chip-scale spectrometers that greatly exceed the performance of table-top grating and interferometer-based devices.

physics.optics