Searcharxiv⌕ Search

arXiv subjects

Zhi Wu

Publications and source records attributed to Zhi Wu.

22 records · Page 2Linked to original sources

Evaluation of new large area PMT with high quantum efficiency

The neutrino detector of the Jiangmen Underground Neutrino Observatory (JUNO) is designed to use 20 kilotons of liquid scintillator and approximately 16,000 20-inch photomultipliers (PMTs).One of the options is to use the 20-inch R12860 PMT with high quantum efficiency which has recently been developed by Hamamatsu Photonics. The performance of the newly developed PMT preproduction samples is evaluated. The results show that its quantum efficiency is $30\%$ at $400 nm$. Its Peak/Valley (P/V) ratio for the single photoelectron is 4.75 and the dark count rate is $27 kHz$ at the threshold of 3 mV while the gain is at $1 \times 10^7$. The transit time spread of a single photoelectron is $2.86 ns$. Generally the performances of this new 20-inch PMT are improved over the old one of R3600.

physics.ins-det↗

The cosmic ray test of MRPCs for the BESIII ETOF upgrade

In order to improve the particle identification capability of the Beijing Spectrometer III (BESIII),t is proposed to upgrade the current endcap time-of-flight (ETOF) detector with multi-gap resistive plate chamber (MRPC) technology. Aiming at extending ETOF overall time resolution better than 100ps, the whole system including MRPC detectors, new-designed Front End Electronics (FEE), CLOCK module, fast control boards and time to digital modules (TDIG), was built up and operated online 3 months under the cosmic ray. The main purposes of cosmic ray test are checking the detectors' construction quality, testing the joint operation of all instruments and guaranteeing the performance of the system. The results imply MRPC time resolution better than 100$ps$, efficiency is about 98$\%$ and the noise rate of strip is lower than 1$Hz/$($scm^{2}$) at normal threshold range, the details are discussed and analyzed specifically in this paper. The test indicates that the whole ETOF system would work well and satisfy the requirements of upgrade.

physics.ins-det↗

Study of the calibration of X-T relation for the BESIII drift chamber

This paper introduces the calibration of the time-to-distance relation for the BESIII drift chamber. The parameterization of the time-to-distance relation is presented. The studies of left-right asymmetry and the variation with the entrance angle are performed. The impact of dead channels on the time-to-distance relation is given special attention in order to reduce the shifts of the measured momenta for the tracks passing near dead cells. Finally we present the spatial resolution (123 μm) for barrel Bhabha events (|cosθ|<0.8) from J/ψ data taken in 2012.

physics.ins-det↗

The high-speed after pulse measurement system for PMT

A system employing a desktop FADC has been developed to investigate the features of 8 inches Hamamatsu PMT. The system stands out for its high-speed and informative results as a consequence of adopting fast waveform sampling technology. Recording full waveforms allows us to perform digital signal processing, pulse shape analysis, and precision timing extraction. High precision after pulse time and charge distribution characteristics are presented in this manuscript. Other photomultipliers characteristics, such as dark rate and transit time spread, can also be obtained by exploiting waveform analysis using this system.

physics.ins-det↗