SearcharxivSearch

arXiv subjects

Zhi-Ang Chen

Publications and source records attributed to Zhi-Ang Chen.

2 recordsLinked to original sources

A nuclear clock based on $^{229}$Th

Atomic clocks have made time and frequency the most precisely measured quantities in physics, progressing from microwave standards that realize the SI second to optical clocks that now reach unprecedented levels of precision. A nuclear clock would shift the frequency reference from an electronic transition to the uniquely low-lying, laser-accessible isomeric transition in the $^{229}$Th nucleus, offering a route to compact, robust timekeeping and sensitive tests of fundamental physics. However, turning recent advances in spectroscopy of the $^{229}$Th nuclear resonance into clock operation requires the nuclear transition to serve as a stable discriminator for steering a traceable oscillator. Here we demonstrate the operation of a $^{229}$Th nuclear clock by stabilizing a continuous-wave narrow-linewidth 148.4 nm vacuum-ultraviolet (VUV) laser to a resolved nuclear transition in a solid-state host. This clock operation is enabled by fast frequency discrimination based on phototube photocurrent readout of the transmitted VUV power. The 10 $\mu$W VUV laser, generated by four-wave mixing in cadmium vapour, provides a high-signal-to-noise absorption signal from a home-grown $^{229}$Th:CaF$_2$ crystal, allowing the laser to be locked to a weakly temperature-sensitive nuclear transition. The clock reaches a fractional frequency instability of $2\times10^{-12}/\sqrt{\tau/s} $, where $\tau$ is the averaging time. Remarkably, nuclear-clock frequencies measured with two distinct crystals agree at the $10^{-13}$ level, demonstrating the reproducibility of solid-state nuclear frequency references. By making a laser-addressed atomic nucleus an operational clock reference, this work extends quantum metrology from electronic to nuclear transitions, and opens a new platform for compact clocks, solid-state nuclear quantum sensors and precision tests of fundamental physics.

physics.atom-ph

A laser with instability reaching $4 \times 10^{-17}$ based on a 10-cm-long silicon cavity at sub-5-K temperatures

The realization of ultra-stable lasers with $10^{-17}$-level frequency stability has enabled a wide range of researches on precision metrology and fundamental science, where cryogenic single-crystalline cavities constitute the heart of such ultra-stable lasers. For further improvements in stability, increasing the cavity length at few-kelvin temperatures provides a promising alternative to utilizing relatively short cavities with novel coating, but has yet to be demonstrated with state-of-the-art stability. Here we report on the realization of a relatively long ultra-stable silicon cavity with a length of 10 cm and sub-5-K operating temperatures. We devise a dynamical protocol of cool-quiet quench measurement that reveals the inherent $10^{-17}$-level frequency instability of the silicon cavity despite the substantially larger frequency noise induced by the cryostat vibration. We further develop a method for suppressing the cryostat-vibration-induced frequency noise under continuous cooling, and observe an average frequency instability of $4.3(2) \times 10^{-17}$ for averaging times of 4 to 12 seconds. Using the measured noise power spectral density, we compute a median linewidth of 9.6(3) mHz for the silicon cavity laser at 1397 nm, which is supported by an empirically determined linewidth of 5.7(3) mHz based on direct optical beat measurements. These results establish a new record for optical cavities within a closed-cycle cryocooler at sub-5-K temperatures and provide a prototypical system for using long cryogenic cavities to enhance frequency stabilities to the low-$10^{-17}$ or better level.

physics.optics