SearcharxivSearch

arXiv subjects

Zhijun Liang

Publications and source records attributed to Zhijun Liang.

At least 19 recordsLinked to original sources

Simulation Study of the Design and Spatial Resolution of a Novel AC-coupled Cross Strip LGAD

AC-coupled Low Gain Avalanche Diode (AC-LGAD), evolved from the standard LGAD technology, are silicon detectors characterized by exceptional temporal and spatial resolutions. This work proposes a novel sensor named AC-coupled Cross Strip LGAD (CS-LGAD) structure with dual-layered overlapping strip electrodes. It can achieve two-dimensional particle position measurement with low readout density while also inheriting the high temporal resolution of the LGAD. The sensor structure, doping and current-voltage (I-V) characteristics of the sensor were investigated through TCAD simulations. Additionally, Monte Carlo simulations were employed to simulate the signal response of CS-LGAD to minimum ionizing particles (MIPs). The response of MIPs hitting different positions was simulated, and the reconstruction of particle coordinates (x and y) was achieved based on the sharing of charges on the dual-layer electrodes. The spatial resolution might reach 3.6% and 5.5% of the pitch size in the x and y directions, respectively, according to the simulation. The proposed CS-LGAD is a promising 4D detector with low mass and low readout density.

physics.ins-det

Status report towards implementation of a Compton polarimeter at BEPCII

Precision beam polarization measurements based on Compton polarimeters are essential for the physics program of future high-energy colliders. In order to prepare for these and to extend the scope of physics measurements of the BESIII experiment at the BEPCII, a diagnostic of electron beam transverse polarization at BEPCII is of interest. The design and status report of the commissioning, until July 2025, of this device is reported in this paper. We report unambiguous observation of Compton interaction, discuss current limitations of the experimental setup and draw prospects for improvements and actual measurement of electron beam polarization in the near future.

physics.acc-ph

Temperature Dependence of Gain and Time Resolution in LGAD Detectors

Low-Gain Avalanche Diodes (LGADs) provide moderate internal gain and time resolutions of a few tens of picoseconds, making them a key technology for ultrafast timing in high-energy physics and beyond. However, both their gain and timing characteristics vary strongly with reverse-bias voltage and temperature. This work establishes a compact analytical framework that describes multi-temperature LGAD gain and timing behavior through an equivalent representation of the gain layer. The non-uniform multiplication region is replaced by an equivalent rectangular gain layer, from which a first-order bias-compensation relation for constant gain is derived and validated. Using multi-temperature measurements of LGADs designed by IHEP and fabricated by IME, together with an independent HPK dataset, we show that the gain-voltage curve family can be reconstructed from a reference-temperature main curve, substantially reducing characterization effort. The same idea is then extended to timing by decomposing the total time resolution into jitter and intrinsic components and representing their temperature dependences as component-wise equivalent bias offsets. The resulting framework provides a function-level description of multi-temperature LGAD time-resolution curves and offers a practical tool for calibration, operation, and reduced-density characterization of LGAD-based ultrafast timing systems.

physics.ins-det

New Physics Search at the CEPC: a General Perspective

The Circular Electron-Positron Collider (CEPC), a proposed next-generation Higgs factory, provides new opportunities to explore physics beyond the Standard Model (SM). With its clean electron-positron collision environment and the ability to collect large samples of Higgs, W, and Z bosons, the CEPC enables precision measurements and searches for new physics. This white paper outlines the CEPC's discovery potential, including studies of exotic decays of the Higgs, Z, and top quarks, dark matter and dark sector phenomena, long-lived particles, supersymmetry, and neutrino-related signatures. Advanced detector technologies and reconstruction techniques, such as one-to-one correspondence reconstruction and jet origin identification, significantly improve sensitivity to rare and weakly interacting processes. The CEPC is particularly well suited to probe the electroweak phase transition and test models of electroweak baryogenesis and dark sector interactions. In addition, global fit analyses highlight the CEPC's complementary role in constraining a wide range of new physics scenarios. These features position the CEPC as a powerful tool for exploring the next frontier in fundamental particle physics in the post-Higgs discovery era.

hep-ex

Flavor Physics at the CEPC: a General Perspective

We discuss the landscape of flavor physics at the Circular Electron-Positron Collider (CEPC), based on the nominal luminosity outlined in its Technical Design Report. The CEPC is designed to operate in multiple modes to address a variety of tasks. At the $Z$ pole, the expected production of 4 Tera $Z$ bosons will provide unique and highly precise measurements of $Z$ boson couplings, while the substantial number of boosted heavy-flavored quarks and leptons produced in clean $Z$ decays will facilitate investigations into their flavor physics with unprecedented precision. We investigate the prospects of measuring various physics benchmarks and discuss their implications for particle theories and phenomenological models. Our studies indicate that, with its highlighted advantages and anticipated excellent detector performance, the CEPC can explore beauty and $τ$ physics in ways that are superior to or complementary with the Belle II and Large-Hadron-Collider-beauty experiments, potentially enabling the detection of new physics at energy scales of 10 TeV and above. This potential also extends to the observation of yet-to-be-discovered rare and exotic processes, as well as testing fundamental principles such as lepton flavor universality, lepton and baryon number conservation, etc., making the CEPC a vibrant platform for flavor physics research. The $WW$ threshold scan, Higgs-factory operation and top-pair productions of the CEPC further enhance its merits in this regard, especially for measuring the Cabibbo-Kobayashi-Maskawa matrix elements, and Flavor-Changing-Neutral-Current physics of Higgs boson and top quarks. We outline the requirements for detector performance and considerations for future development to achieve the anticipated scientific goals.

hep-ex

Test of LGAD as Potential Next-Generation μSR Spectrometer Detectors

Muon Spin Rotation/Relaxation/Resonance ($μ$SR) is a versatile and powerful non-destructive technology for investigating the magnetic properties of materials at the microscopic level. The $μ$SR technique typically utilizes fully spin polarized beams of positive muons generated at particle accelerator facilities and measures the evolution of the muon spin polarization inside a sample to extract information about the local magnetic environment in materials. With the development of accelerator technologies, intensities of muon beams are being continuously improved, which will cause a pile-up problem to the $μ$SR spectrometer. The first muon source in China, named MELODY, is currently under construction and will be a pulsed source of muons operated at a repetition frequency of only 1 Hz due to limitations of the accelerator system at CSNS. Consequently, there is a strong motivation to operate MELODY at significantly higher muon intensities. This necessitates an upgrade of the detector system inside the spectrometer, which should be smaller and faster to accommodate the increased intensity per pulse of muons. The Low Gain Avalanche Diode (LGAD), characterized by a typical pulse width of 2 ns and a segmentation size in the centimeters range, has the potential to significantly improve the counting rates of $μ$SR spectrometers that utilize a high intensity pulsed muon source. Thus, it is expected that the LGAD detector is a promising candidate to enhance the performance of $μ$SR spectrometers at the new MELODY muon source.To validate this, tests on the LGAD were conducted at the ISIS pulsed muon source at the Rutherford Appleton Laboratory, UK. This paper will describe the setup of the candidate LGAD devices and the subsequent analysis of the experiment data.

physics.ins-det

Beam test result and digitization of TaichuPix-3: A Monolithic Active Pixel Sensors for CEPC vertex detector

The Circular Electron-Positron Collider (CEPC), as the next-generation electron-positron collider, is tasked with advancing not only Higgs physics but also the discovery of new physics. Achieving these goals requires high-precision measurements of particles. Taichu seires, Monolithic Active Pixel Sensor (MAPS), a key component of the vertex detector for CEPC was designed to meet the CEPC's requirements. For the geometry of vertex detector is long barrel with no endcap, and current silicon lacks a complete digitization model, precise estimation of cluster size particularly causing by particle with large incident angle is needed. Testbeam results were conducted at the Beijing Synchrotron Radiation Facility (BSRF) to evaluate cluster size dependence on different incident angles and threshold settings. Experimental results confirmed that cluster size increases with incident angle. Simulations using the Allpix$^2$ framework replicated experimental trends at small angles but exhibited discrepancies at large angles, suggesting limitations in linear electric field assumptions and sensor thickness approximations. The results from both testbeam and simulations have provided insights into the performance of the TaichuPix chip at large incident angles, offering a crucial foundation for the establishment of a digital model and addressing the estimation of cluster size in the forward region of the long barrel. Furthermore, it offers valuable references for future iterations of TaichuPix, the development of digital models, and the simulation and estimation of the vertex detector's performance.

physics.ins-det

The Performance of AC-coupled Strip LGAD developed by IHEP

The AC-coupled Strip LGAD (Strip AC-LGAD) is a novel LGAD design that diminishes the density of readout electronics through the use of strip electrodes, enabling the simultaneous measurement of time and spatial information. The Institute of High Energy Physics has designed a long Strip AC-LGAD prototype with a strip electrode length of 5.7 mm and pitches of 150 $μm$, 200 $μm$, and 250 $μm$. Spatial and timing resolutions of the long Strip AC-LGAD are studied by pico-second laser test and beta source tests. The laser test demonstrates that spatial resolution improves as the pitch size decreases, with an optimal resolution achieved at 8.3 $μ$m. Furthermore, the Beta source test yields a timing resolution of 37.6 ps.

physics.ins-det

Development of the strip LGAD detector with double-end readout for future colliders

The Low-Gain Avalanche Diode (LGAD) is a new silicon detector and holds wide application prospects in particle physics experiments due to its excellent timing resolution. The LGAD with a pixel size of 1.3 mm $\times$ 1.3 mm was used to construct a High Granularity Timing Detector (HGTD) in ATLAS experiments to solve the pile-up problem. Meanwhile, the Circular Electron Positron Collider (CEPC) also proposes detectors using the LGAD. However, pixel LGAD exhibits higher readout electronics density and cost, which somewhat limits the application of LGADs. To decrease the readout electronics density, the Institute of High Energy Physics (IHEP) of the Chinese Academy of Sciences has designed strip LGADs with larger areas. These strip LGADs are all 19 mm in length but with different widths of 1.0 mm, 0.5 mm, and 0.3 mm. This article provides a detailed introduction to the design parameters of these strip LGADs and tests their electrical characteristics, including leakage current, break-down voltage, depletion capacitance, etc. The timing resolution and signal-to-noise ratio of the three strip LGAD sensors were investigated using a beta source test system. The position resolution parallel to the strip direction was tested and analyzed for the first time using a pico-second laser test system. Tests have demonstrated that the timing resolution of strip LGADs can reach about 37.5 ps, and position resolution parallel to the strip direction is better than 1 mm.

physics.ins-det

The Physics potential of the CEPC. Prepared for the US Snowmass Community Planning Exercise (Snowmass 2021)

The Circular Electron Positron Collider (CEPC) is a large-scale collider facility that can serve as a factory of the Higgs, Z, and W bosons and is upgradable to run at the ttbar threshold. This document describes the latest CEPC nominal operation scenario and particle yields and updates the corresponding physics potential. A new detector concept is also briefly described. This submission is for consideration by the Snowmass process.

hep-ph

Beam test of a baseline vertex detector prototype for CEPC

The Circular Electron Positron Collider (CEPC) has been proposed to enable more thorough and precise measurements of the properties of Higgs, W, and Z bosons, as well as to search for new physics. In response to the stringent performance requirements of the vertex detector for the CEPC, a baseline vertex detector prototype was tested and characterized for the first time using a 6 GeV electron beam at DESY II Test Beam Line 21. The baseline vertex detector prototype is designed with a cylindrical barrel structure that contains six double-sided detector modules (ladders). Each side of the ladder includes TaichuPix-3 sensors based on Monolithic Active Pixel Sensor (MAPS) technology, a flexible printed circuit, and a carbon fiber support structure. Additionally, the readout electronics and the Data Acquisition system were also examined during this beam test. The performance of the prototype was evaluated using an electron beam that passed through six ladders in a perpendicular direction. The offline data analysis indicates a spatial resolution of about 5 um, with detection efficiency exceeding 99 % and an impact parameter resolution of about 5.1 um. These promising results from this baseline vertex detector prototype mark a significant step toward realizing the optimal vertex detector for the CEPC.

physics.ins-det

Beam test of a 180 nm CMOS Pixel Sensor for the CEPC vertex detector

The proposed Circular Electron Positron Collider (CEPC) imposes new challenges for the vertex detector in terms of pixel size and material budget. A Monolithic Active Pixel Sensor (MAPS) prototype called TaichuPix, based on a column drain readout architecture, has been developed to address the need for high spatial resolution. In order to evaluate the performance of the TaichuPix-3 chips, a beam test was carried out at DESY II TB21 in December 2022. Meanwhile, the Data Acquisition (DAQ) for a muti-plane configuration was tested during the beam test. This work presents the characterization of the TaichuPix-3 chips with two different processes, including cluster size, spatial resolution, and detection efficiency. The analysis results indicate the spatial resolution better than 5 $μm$ and the detection efficiency exceeds 99.5 % for both TaichuPix-3 chips with the two different processes.

physics.ins-det

Performance of AC-LGAD strip sensor designed for the DarkSHINE experiment

AC-coupled Low Gain Avalanche Detector (AC-LGAD) is a new precise detector technology developed in recent years. Based on the standard Low Gain Avalanche Detector (LGAD) technology, AC-LGAD sensors can provide excellent timing performance and spatial resolution. This paper presents the design and performance of several prototype AC-LGAD strip sensors for the DarkSHINE tracking system, as well as the electrical characteristics and spatial resolution of the prototype sensors from two batches of wafers with different $n^+$ dose.The range of spatial resolutions of 6.5$\mathrm{μm}$ $\sim$ 8.2$\mathrm{μm}$ and 8.8$\mathrm{μm}$ $\sim$ 12.3$\mathrm{μm}$ are achieved by the AC-LGAD sensors with 100$μm$ pitch size.

physics.ins-det

Test to the Performance of a LGAD Based Zero Degree Detector on CSNS Back-n Beamline

A comprehensive and reliable nuclear database of neutron-induced process is required by the development of Accelerator-Driven System technology. Although many excellent efforts have been made, the measurements to the fission fragment in zero degree of the beam direction is not perfect enough. Most detector can not work constantly under the strike of intense flux neutron beam, thus their application as Zero Degree Detector (ZDD) is greatly limited. Recently, the Low Gain Avalanche Diode (LGAD) technology has been developed to meet the complicated and several requirement of ATLAS on Large Hadron Collider (LHC) and could survive after $2.5\times 10^{15}~n_{eq}/cm^2$ irradiation. With its 50 $μ$m active thickness, 30 ps temporal resolution, low cost and good radiation hardness property, the LGAD detector is expected to be an excellent candidate for the use of a Zero Degree Detector in neutron-induced process data measurements. This paper represents a performance test to LGAD detector when it is used as a ZDD on the Back-streaming Neutron (Back-n) beamline at CSNS. Measuring to the cross section of $^6Li(n,T)α$, it shows that the LGAD performs well as a ZDD based on a good agreement with the data from ENDF database.

physics.ins-det

The performance of large-pitch AC-LGAD with different N+ dose

AC-Coupled LGAD (AC-LGAD) is a new 4D detector developed based on the Low Gain Avalanche Diode (LGAD) technology, which can accurately measure the time and spatial information of particles. The Institute of High Energy Physics (IHEP) designed a large-size AC-LGAD with a pitch of 2000~\SI{}{\micro\metre} and AC pad of 1000~\SI{}{\micro\metre}, and explored the effect of N+ layer dose on the spatial resolution and time resolution. The spatial resolution varied from 36~\SI{}{\micro\metre} to 16~\SI{}{\micro\metre} depending on N+ dose for a charge corresponding to about 12 minimum ionizing particles. The jitter component of the time resolution does not change significantly with different N+ doses, and it is about 15-17 ps measured by laser. The AC-LGAD with a low N+ dose has a large attenuation factor and better spatial resolution in the central region between pads. In these specific conditions, large signal attenuation factor and low noise level are beneficial to improve the spatial resolution of the AC-LGAD sensor.

physics.ins-det

Characterization of the response of IHEP-IME LGAD with shallow carbon to Gamma Irradiation

Low Gain Avalanche Detectors (LGAD) for the High-Granularity Timing Detector (HGTD) are crucial in reducing pileups in the High-Luminosity Large Hadron Collider. Numerous studies have been conducted on the bulk irradiation damage of LGADs. However, few studies have been carried out on the surface irradiation damage of LGAD sensors with shallow carbon implantation. In this paper, the IHEP-IME LGADs with shallow carbon implantation were irradiated up to 2 MGy using gamma irradiation to investigate surface damage. Important characteristic parameters, including leakage currents, breakdown voltage (BV), inter-pad resistances, and capacitances, were tested before and after irradiation. The results showed that the leakage current and BV increased after irradiation, whereas overall inter-pad resistance exhibited minimal change and remained above $10^9\ Ω$ before and after irradiation. Capacitance was found to be less than 4.5 pF with a slight decrease in the gain layer depletion voltage (V$_{gl}$) after irradiation. No parameter affected by the inter-pad separation was observed before and after irradiation. All characteristic parameters meet the requirements of HGTD, and this design can be used to further optimization.

physics.ins-det

MUX64, an analogue 64-to-1 multiplexer ASIC for the ATLAS High Granularity Timing Detector

We present the design and the performance of MUX64, a 64-to-1 analogue multiplexer ASIC for the ATLAS High Granularity Timing Detector (HGTD). The MUX64 transmits one of its 64 inputs selected by six address lines for the voltages or temperatures being monitored to an lpGBT ADC channel. The prototype ASICs fabricated in TSMC 130 nm CMOS technology were prepared in wire-bonding and QFN88 packaging format. A total of 280 chips was examined for functionality and quality assurance. The accelerated aging test conducted at 85 degrees celsius shows negligible degradation over 16 days.

physics.ins-det

Report of the Topical Group on Electroweak Precision Physics and Constraining New Physics for Snowmass 2021

The precise measurement of physics observables and the test of their consistency within the standard model (SM) are an invaluable approach, complemented by direct searches for new particles, to determine the existence of physics beyond the standard model (BSM). Studies of massive electroweak gauge bosons (W and Z bosons) are a promising target for indirect BSM searches, since the interactions of photons and gluons are strongly constrained by the unbroken gauge symmetries. They can be divided into two categories: (a) Fermion scattering processes mediated by s- or t-channel W/Z bosons, also known as electroweak precision measurements; and (b) multi-boson processes, which include production of two or more vector bosons in fermion-antifermion annihilation, as well as vector boson scattering (VBS) processes. The latter categories can test modifications of gauge-boson self-interactions, and the sensitivity is typically improved with increased collision energy. This report evaluates the achievable precision of a range of future experiments, which depend on the statistics of the collected data sample, the experimental and theoretical systematic uncertainties, and their correlations. In addition it presents a combined interpretation of these results, together with similar studies in the Higgs and top sector, in the Standard Model effective field theory (SMEFT) framework. This framework provides a model-independent prescription to put generic constraints on new physics and to study and combine large sets of experimental observables, assuming that the new physics scales are significantly higher than the EW scale.

hep-ph