SearcharxivSearch

arXiv subjects

Zi-Rui Zhong

Publications and source records attributed to Zi-Rui Zhong.

4 recordsLinked to original sources

Transfer of Fisher Information in Quantum Postselection Metrology

Postselected weak measurement has shown significant potential for detecting small physical effects due to its unique weak-value-amplification phenomenon. Previous works suggest that Heisenberg-limit precision can be attained using only the optical coherent states. However, the measurement object is the distribution of postselection, limiting the practical applicability. Here, we demonstrate that the output photons can also reach the quantum scale by utilizing the Fisher information transfer effect. In addition, we consider the insertion of a power-recycling cavity and demonstrate its positive impact on the distribution of postselection. Our results enhance the quantum metrological advantages of the postselection strategy and broaden its application scope.

quant-ph

Entanglement-assist cyclic weak-value-amplification metrology

Weak measurement has garnered widespread interest for its ability to amplify small physical effects at the cost of low detection probabilities. Previous entanglement and recycling techniques enhance postselection efficiency and signal-to-noise ratio (SNR) of weak measurement from distinct perspectives. Here, we incorporate a power recycling cavity into the entanglement-assisted weak measurement system. We obtain an improvement of both detection efficiency and Fisher information, and find that the improvement from entanglement and recycling occur in different dimensions. Furthermore, we analyze two types of errors, walk-off errors and readout errors. The conclusions suggest that entanglement exacerbates the walk-off effect caused by recycling, but this detriment can be balanced by proper parameter selection. In addition, power-recycling can complement entanglement in suppressing readout noise, thus enhancing the accuracy in the measurement results and recovering the lost Fisher information. This work delves deeper into the metrological advantages of weak measurement.

quant-ph

Polarization-based cyclic weak value metrology for angular velocity measurement

Weak measurement has been proven to amplify the detection of changes in meters while discarding most photons due to the low probability of post-selection. Previous power-recycling schemes enable the failed post-selection photons to be repeatedly selected, thus overcoming the inefficient post-selection and increasing the precision of detection. In this study, we focus on the polarization-based weak value angular-velocity measurement and introduce three cyclic methods to enhance the accuracy of detecting time shift in a Gaussian beam: power recycling, signal recycling, and dual recycling schemes. By incorporating one or two partially transmitting mirrors into the system, both the power and signal-to-noise ratio (SNR) of the detected light are substantially enhanced. Compared to non-polarization schemes, polarization-based approaches offer several advantages, including lower optical loss, unique cyclic directions, and a wider optimal region. These features effectively reduce crosstalk among different light paths and theoretically eliminate the walk-off effect, thus yielding improvements in both theoretical performance and application.

quant-ph

Dual-recycled interference-based weak value metrology

Weak-value-amplification permits small effects to be measured as observable changes at the sacrifice of power due to post-selection. The power recycling scheme has been proven to eliminate this inefficiency of the rare post-selection, thus surpassing the limit of the shot noise and improving the precision of the measurement. However, the improvement is strictly limited by the system setup, especially the system loss. Here we introduce a dual recycling model based on the interferometric weak-value-based deflection measurement. Two mirrors, the power-recycling mirror and signal-recycling mirror, are placed at the bright and dark port of the interferometer respectively, creating a composite resonator. The results show that both the power and the signal-to-noise ratio (SNR) are greatly enhanced in a wider range of experimental parameters compared to the power-recycling scheme. This work considerably loosens the constraint of the system setup and further explores the real advantage of weak measurement over traditional schemes.

physics.optics