SearcharxivSearch

arXiv subjects

Zibang Zhang

Publications and source records attributed to Zibang Zhang.

14 recordsLinked to original sources

Solving combinational optimization problems with evolutionary single-pixel imaging

Single-pixel imaging (SPI) is a novel optical imaging technique by replacing the pixelated sensor array in a conventional camera with a single-pixel detector. In previous works, SPI is usually used for capturing object images or performing image processing tasks. In this work, we propose a SPI scheme for processing other types of data in addition to images. An Ising machine model is implemented optically with SPI for solving combinational optimization problems including number partition and graph maximum cut. Simulated and experimental results show that our proposed scheme can optimize the Hamiltonian function with evolutionary illumination patterns.

cs.CV

Playing Tic-Tac-Toe Games with Intelligent Single-pixel Imaging

Single-pixel imaging (SPI) is a novel optical imaging technique by replacing a two-dimensional pixelated sensor with a single-pixel detector and pattern illuminations. SPI have been extensively used for various tasks related to image acquisition and processing. In this work, a novel non-image-based task of playing Tic-Tac-Toe games interactively is merged into the framework of SPI. An optoelectronic artificial intelligent (AI) player with minimal digital computation can detect the game states, generate optimal moves and display output results mainly by pattern illumination and single-pixel detection. Simulated and experimental results demonstrate the feasibility of proposed scheme and its unbeatable performance against human players.

cs.CV

Ptychographic sensor for large-scale lensless microbial monitoring with high spatiotemporal resolution

Traditional microbial detection methods often rely on the overall property of microbial cultures and cannot resolve individual growth event at high spatiotemporal resolution. As a result, they require bacteria to grow to confluence and then interpret the results. Here, we demonstrate the application of an integrated ptychographic sensor for lensless cytometric analysis of microbial cultures over a large scale and with high spatiotemporal resolution. The reported device can be placed within a regular incubator or used as a standalone incubating unit for long-term microbial monitoring. For longitudinal study where massive data are acquired at sequential time points, we report a new temporal-similarity constraint to increase the temporal resolution of ptychographic reconstruction by 7-fold. With this strategy, the reported device achieves a centimeter-scale field of view, a half-pitch spatial resolution of 488 nm, and a temporal resolution of 15-second intervals. For the first time, we report the direct observation of bacterial growth in a 15-second interval by tracking the phase wraps of the recovered images, with high phase sensitivity like that in interferometric measurements. We also characterize cell growth via longitudinal dry mass measurement and perform rapid bacterial detection at low concentrations. For drug-screening application, we demonstrate proof-of-concept antibiotic susceptibility testing and perform single-cell analysis of antibiotic-induced filamentation. The combination of high phase sensitivity, high spatiotemporal resolution, and large field of view is unique among existing microscopy techniques. As a quantitative and miniaturized platform, it can improve studies with microorganisms and other biospecimens at resource-limited settings.

physics.ins-det

Resolution-enhanced parallel coded ptychography for high-throughput optical imaging

Ptychography is an enabling coherent diffraction imaging technique for both fundamental and applied sciences. Its applications in optical microscopy, however, fall short for its low imaging throughput and limited resolution. Here, we report a resolution-enhanced parallel coded ptychography technique achieving the highest numerical aperture and an imaging throughput orders of magnitude greater than previous demonstrations. In this platform, we translate the samples across the disorder-engineered surfaces for lensless diffraction data acquisition. The engineered surface consists of chemically etched micron-level phase scatters and printed sub-wavelength intensity absorbers. It is designed to unlock an optical space with spatial extent (x, y) and frequency content (kx, ky) that is inaccessible using conventional lens-based optics. To achieve the best resolution performance, we also report a new coherent diffraction imaging model by considering both the spatial and angular responses of the pixel readouts. Our low-cost prototype can directly resolve 308-nm linewidth on the resolution target without aperture synthesizing. Gigapixel high-resolution microscopic images with a 240-mm^2 effective field of view can be acquired in 15 seconds. For demonstrations, we recover slow-varying 3D phase objects with many 2π wraps, including optical prism and convex lens. The low-frequency phase contents of these objects are challenging to obtain using other existing lensless techniques. For digital pathology applications, we perform accurate virtual staining by using the recovered phase as attention guidance in a deep neural network. Parallel optical processing using the reported technique enables novel optical instruments with inherent quantitative nature and metrological versatility.

physics.optics

Optofluidic ptychography on a chip

We report the implementation of a fully on-chip, lensless microscopy technique termed optofluidic ptychography. This imaging modality complements the miniaturization provided by microfluidics and allows the integration of ptychographic microscopy into various lab-on-a-chip devices. In our prototype, we place a microfluidic channel on the top surface of a coverslip and coat the bottom surface with a scattering layer. The channel and the coated coverslip substrate are then placed on top of an image sensor for diffraction data acquisition. Similar to the operation of flow cytometer, the device utilizes microfluidic flow to deliver specimens across the channel. The diffracted light from the flowing objects is modulated by the scattering layer and recorded by the image sensor for ptychographic reconstruction, where high-resolution quantitative complex images are recovered from the diffraction measurements. By using an image sensor with a 1.85-micron pixel size, our device can resolve the 550 nm linewidth on the resolution target. We validate the device by imaging different types of biospecimens, including C. elegans, yeast cells, paramecium, and closterium sp. We also demonstrate high-resolution ptychographic reconstruction at a video framerate of 30 frames per second. The reported technique can address a wide range of biomedical needs and engenders new ptychographic imaging innovations in a flow cytometer configuration.

physics.ins-det

High-throughput lensless whole slide imaging via continuous height-varying modulation of tilted sensor

We report a new lensless microscopy configuration by integrating the concepts of transverse translational ptychography and defocus multi-height phase retrieval. In this approach, we place a tilted image sensor under the specimen for linearly-increasing phase modulation along one lateral direction. Similar to the operation of ptychography, we laterally translate the specimen and acquire the diffraction images for reconstruction. Since the axial distance between the specimen and the sensor varies at different lateral positions, laterally translating the specimen effectively introduces defocus multi-height measurements while eliminating axial scanning. Lateral translation further introduces sub-pixel shift for pixel super-resolution imaging and naturally expands the field of view for rapid whole slide imaging. We show that the equivalent height variation can be precisely estimated from the lateral shift of the specimen, thereby addressing the challenge of precise axial positioning in conventional multi-height phase retrieval. Using a sensor with a 1.67-micron pixel size, our low-cost and field-portable prototype can resolve 690-nm linewidth on the resolution target. We show that a whole slide image of a blood smear with a 120-mm^2 field of view can be acquired in 18 seconds. We also demonstrate accurate automatic white blood cell counting from the recovered image. The reported approach may provide a turnkey solution for addressing point-of-care- and telemedicine-related challenges.

eess.IV

Efficient Fourier single-pixel imaging with Gaussian random sampling

Fourier single-pixel imaging (FSI) is a branch of single-pixel imaging techniques. It uses Fourier basis patterns as structured patterns for spatial information acquisition in the Fourier domain. However, the spatial resolution of the image reconstructed by FSI mainly depends on the number of Fourier coefficients sampled. The reconstruction of a high-resolution image typically requires a number of Fourier coefficients to be sampled, and therefore takes a long data acquisition time. Here we propose a new sampling strategy for FSI. It allows FSI to reconstruct a clear and sharp image with a reduced number of measurements. The core of the proposed sampling strategy is to perform a variable density sampling in the Fourier space and, more importantly, the density with respect to the importance of Fourier coefficients is subject to a one-dimensional Gaussian function. Combined with compressive sensing, the proposed sampling strategy enables better reconstruction quality than conventional sampling strategies, especially when the sampling ratio is low. We experimentally demonstrate compressive FSI combined with the proposed sampling strategy is able to reconstruct a sharp and clear image of 256-by-256 pixels with a sampling ratio of 10%. The proposed method enables fast single-pixel imaging and provides a new approach for efficient spatial information acquisition.

eess.IV

Autofocusing technologies for whole slide imaging and automated microscopy

Whole slide imaging (WSI) has moved digital pathology closer to diagnostic practice in recent years. Due to the inherent tissue topography variability, accurate autofocusing remains a critical challenge for WSI and automated microscopy systems. The traditional focus map surveying method is limited in its ability to acquire a high degree of focus points while still maintaining high throughput. Real-time approaches decouple image acquisition from focusing, thus allowing for rapid scanning while maintaining continuous accurate focus. This work reviews the traditional focus map approach and discusses the choice of focus measure for focal plane determination. It also discusses various real-time autofocusing approaches including reflective-based triangulation, confocal pinhole detection, low-coherence interferometry, tilted sensor approach, independent dual sensor scanning, beam splitter array, phase detection, dual-LED illumination, and deep-learning approaches. The technical concepts, merits, and limitations of these methods are explained and compared to those of a traditional WSI system. This review may provide new insights for the development of high-throughput automated microscopy imaging systems that can be made broadly available and utilizable without loss of capacity.

physics.med-ph

Super-resolved multispectral lensless microscopy via angle-tilted, wavelength-multiplexed ptychographic modulation

We report an angle-tilted, wavelength-multiplexed ptychographic modulation approach for multispectral lensless on-chip microscopy. In this approach, we illuminate the specimen with lights at 5 wavelengths simultaneously. A prism is added at the illumination path for spectral dispersion. Lightwaves at different wavelengths, thus, hit the specimen at slightly different incident angles, breaking the ambiguities in mixed state ptychographic reconstruction. At the detection path, we place a thin diffuser in-between the specimen and the monochromatic image sensor for encoding the spectral information into 2D intensity measurements. By scanning the sample to different x-y positions, we acquire a sequence of monochromatic images for reconstructing the 5 complex object profiles at the 5 wavelengths. An up-sampling procedure is integrated into the recovery process to bypass the resolution limit imposed by the imager pixel size. We demonstrate a half-pitch resolution of 0.55 microns using an image sensor with 1.85-micron pixel size. We also demonstrate quantitative and high-quality multispectral reconstructions of stained tissue sections for digital pathology applications.

physics.optics

Image-free real-time classification of fast moving objects using 'learned' spatial light modulation and a single-pixel detector

Objects classification generally relies on image acquisition and analysis. Real-time classification of high-speed moving objects is challenging, as both high temporal resolution in image acquisition and low computational complexity in objects classification algorithms are required. Here we propose and experimentally demonstrate an approach for real-time moving objects classification without image acquisition. As objects classification algorithms rely on the feature information of objects, we propose to use spatial light modulation to acquire the feature information directly rather than performing image acquisition followed by features extraction. A convolutional neural network is designed and trained to learn the spatial features of the target objects. The trained network can generate structured patterns for spatial light modulation. Using the resulting structured patterns for spatial light modulation, the feature information of target objects can be compressively encoded into a short light intensity sequence. The resulting one-dimensional signal is collected by a single-pixel detector and fed to the convolutional neural network for objects classification. As experimentally demonstrated, the proposed approach can achieve accurate and real-time classification of fast moving objects. The proposed method has potential applications in the fields where fast moving objects classification in real time and for long duration is required.

eess.IV

Optical synthetic sampling imaging: concept and an example of microscopy

Digital two-dimensional (2D) spatial sampling devices (such as charge-coupled device) have been widely used in various imaging systems, especially in computational imaging systems. However, the undersampling of digital sampling devices is a problem that limits the resolution of the acquired images. In this study, we present a synthetic sampling imaging (SSI) concept to solve the undersampling problem. It combines the structured illumination system and conventional 2D image detection system to simultaneously sample the specimen from the illumination and the detection sides. Then, we synthesize the illumination sampling rate and the detection sampling rate to reconstruct a high sampling rate image. The concept of the proposed SSI is demonstrated by an example of microscopy. Experimental results confirm that the proposed method can double the sampling resolution of the microscope. The synthetic sampling scheme, where the sampling task is shared by the illumination and detection sides, provides insight for resolving the undersampling problem of the digital imaging system.

eess.IV

Hadamard single-pixel imaging versus Fourier single-pixel imaging

Single-pixel imaging is an innovative imaging scheme and has received increasing attentions in recent years. It is applicable to imaging at non-visible wavelengths and imaging under low light conditions. However, single-pixel imaging has once encountered problems of low reconstruction quality and long data-acquisition time. This situation has been changed thanks to the developments of Hadamard single-pixel imaging (HSI) and Fourier single-pixel imaging (FSI). Both techniques are able to achieve high-quality and efficient imaging, remarkably improving the applicability of single-pixel imaging scheme. In this paper, we compare the performances of HSI and FSI with theoretical analysis and experiments. The results show that FSI is more efficient than HSI while HSI is more noise-robust than FSI. Our work may provide a guideline for researchers to choose suitable single-pixel imaging technique for their applications.

physics.optics

Dual-LED-based multichannel microscopy for whole-slide multiplane, multispectral, and phase imaging

We report the development of a multichannel microscopy for whole-slide multiplane, multispectral, and phase imaging. We use trinocular heads to split the beam path into 6 independent channels and employ a camera array for parallel data acquisition, achieving a maximum data throughput of ~1 gigapixel per second. To perform single-frame rapid autofocusing, we place two near-infrared LEDs at the back focal plane of the condenser lens to illuminate the sample from two different incident angles. A hot mirror is used to direct the near-infrared light to an autofocusing camera. For multiplane whole slide imaging (WSI), we acquire 6 different focal planes of a thick specimen simultaneously. For multispectral WSI, we relay the 6 independent image planes to the same focal position and simultaneously acquire information at 6 spectral bands. For whole-slide phase imaging, we acquire images at 3 focal positions simultaneously and use the transport-of-intensity equation to recover the phase information. We also provide an open-source design to further increase the number of channels from 6 to 15. The reported platform provides a simple solution for multiplexed fluorescence imaging and multimodal WSI. Acquiring an instant focal stack without z-scanning may also enable fast 3D dynamic tracking of various biological samples.

physics.ins-det

Fast Fourier single-pixel imaging using binary illumination

Fourier single-pixel imaging (FSI) has proven capable of reconstructing high-quality two-dimensional and three-dimensional images. The utilization of the sparsity of natural images in Fourier domain allows high-resolution images to be reconstructed from far fewer measurements than effective image pixels. However, applying original FSI in digital micro-mirror device (DMD) based high-speed imaging system turns out to be challenging, because the original FSI uses grayscale Fourier basis patterns for illumination while DMDs generate grayscale patterns at a relatively low rate. DMDs are a binary device which can only generate a black-and-white pattern at each instance. In this paper, we adopt binary Fourier patterns for illumination to achieve DMD-based high-speed single-pixel imaging. Binary Fourier patterns are generated by upsampling and then applying error diffusion based dithering to the grayscale patterns. Experiments demonstrate the proposed technique able to achieve static imaging with high quality and dynamic imaging in real time. The proposed technique potentially allows high-quality and high-speed imaging over broad wavebands.

cs.CV