Accurate Frequency Response Modeling in Integrated T&D Co-Simulation via EWMA-RTTA-Based Quadratic Extrapolation

The large-scale integration of inverter-based resources (IBRs), particularly distributed photovoltaics (DPVs), into distribution networks increases the need for integrated transmission and distribution (T&D) co-simulation. A key challenge in such co-simulation lies in accurately modeling system frequency across two asynchronous simulation environments. For example, the transmission system, simulated in the phasor domain, can operate with a simulation timestep of 10 ms, while the distribution system, simulated in the electromagnetic transient domain (EMT) to include IBR models, uses a much finer timestep of 100 microseconds. To ensure accurate PLL-based frequency estimation in distribution systems, it is essential to predict voltage magnitude and phase angle variations within the 10 ms transmission intervals, rather than using constant values that cause inaccurate frequency calculations. This issue becomes particularly critical when modeling primary and secondary frequency response services provided by IBRs. To address this challenge, we propose an automated Exponentially Weighted Moving Average Real-Time Threshold Adaptation (EWMA-RTTA) method, which utilizes Quadratic Extrapolation to predict voltage magnitude and phase angle trends more precisely. The proposed method is validated using two Opal-RT simulators: one simulating an IEEE 118-bus transmission system and the other simulating an IEEE 123-bus distribution network. Simulation results demonstrate that our approach improves the normalized mean absolute error (nMAE) by a factor of 25.7 compared to methods that do not account for time mismatches, offering a scalable and accurate solution for modeling IBR-based frequency response in modern power systems.

eess.SY

Dose rate effects in radiation-induced changes to phenyl-based polymeric scintillators

Results on the effects of ionizing radiation on the signal produced by plastic scintillating rods manufactured by Eljen Technology company are presented for various matrix materials, dopant concentrations, fluors (EJ-200 and EJ-260), anti-oxidant concentrations, scintillator thickness, doses, and dose rates. The light output before and after irradiation is measured using an alpha source and a photomultiplier tube, and the light transmission by a spectrophotometer. Assuming an exponential decrease in the light output with dose, the change in light output is quantified using the exponential dose constant $D$. The $D$ values are similar for primary and secondary doping concentrations of 1 and 2 times, and for antioxidant concentrations of 0, 1, and 2 times, the default manufacturer's concentration. The $D$ value depends approximately linearly on the logarithm of the dose rate for dose rates between 2.2 Gy/hr and 70 Gy/hr for all materials. For EJ-200 polyvinyltoluene-based (PVT) scintillator, the dose constant is approximately linear in the logarithm of the dose rate up to 3400 Gy/hr, while for polystyrene-based (PS) scintillator or for both materials with EJ-260 fluors, it remains constant or decreases (depending on doping concentration) above about 100 Gy/hr. The results from rods of varying thickness and from the different fluors suggest damage to the initial light output is a larger effect than color center formation for scintillator thickness $\leq1$ cm. For the blue scintillator (EJ-200), the transmission measurements indicate damage to the fluors. We also find that while PVT is more resistant to radiation damage than PS at dose rates higher than about 100 Gy/hr for EJ-200 fluors, they show similar damage at lower dose rates and for EJ-260 fluors.

physics.ins-det