Searcharxiv⌕ Search

arXiv subjects

Ziyang Long

Publications and source records attributed to Ziyang Long.

6 recordsLinked to original sources

Looking Right Is Not Being Right: Evaluating the Geometry of Agent-Built 3D Scenes

Vision-language agents can reconstruct rooms from video as editable 3D scenes, but convincing renders do not establish geometric accuracy. We introduce a scan-referenced evaluation and use controlled experiments to study reconstruction accuracy, the role of geometric inputs, and agents' ability to verify and correct their scenes. Our geometric score measures surface, depth, and furniture placement agreement with laser scans of 30 real rooms on a 0-100 scale. The strongest tested agent, GPT-6 Astra, scores 51.4 from video alone, while a dense reconstruction from the same video scores 75.9. Given the point cloud used for that reconstruction, Astra produces an editable scene that scores within three points of it. Agents also inherit input errors: rescaling the supplied geometry changes scene scale almost proportionally. During revision, viewing renders improves appearance more consistently than geometry. Logs of their tool calls show that agents repeatedly measure their inputs but rarely compare them with the scenes they build. To provide this missing check, we introduce a geometric error report that compares each saved scene with the agent's input points and lists the largest discrepancies. Without new geometric evidence, the report raises the revision gains of GPT-6.1 Terra and Sol by 3.9 and 5.5 points over concurrent controls.

cs.CV↗

MedImageOSWorld: Benchmarking GUI Agents for Medical Image Consoles

Graphical consoles offer a practical interface for medical acquisition assistance, allowing agents to work through the controls and visual feedback used by human operators. Reliable assistance requires linking on-screen anatomy to acquisition decisions that determine what image evidence becomes available next. We introduce MedImageOSWorld, a benchmark for evaluating this capability in simulated CT, MR, and ultrasound consoles. Using screenshots and mouse-and-keyboard actions, agents configure protocols, plan acquisitions, inspect the resulting images, and make corrective adjustments across seven capability levels, from console operation to feedback-driven control. Evaluation combines task-specific workflow checks with hidden anatomical ground truth to assess procedural completion and acquisition outcomes separately. A common evaluation protocol specifies episode conditions and interaction budgets, while recorded trajectories support analysis of how agents observe, act, and respond to acquisition feedback. Across eleven open-weight agents, success rates range from 3.0 to 25.0 on a 0-100 scale while workflow-progress rates reach 21.5-74.5: agents complete much of the console workflow but rarely acquire the intended anatomy. Success collapses between perception and planning, from 79-90% at the lowest three levels for the best agent to at most 12% for millimetre-level planning and 0% for closed-loop control among open-weight agents. Two proprietary agents reach success rates of about 34 and exceed the best open-weight agent mainly in acquisition quality (61 versus 42). MedImageOSWorld provides a controlled setting for studying whether general-purpose GUI agents can translate visual observations into effective medical acquisition decisions.

cs.AI↗

AtlasGS: Brain MRI Spatial Resolution Harmonization With Shared Gaussian Geometry

Splatting (GS)-based shared geometry framework adopts a two-stage training strategy, in which an explicit, subject-specific Gaussian scaffold encoding anatomical geometry is first learned from the isotropic structural scan and then reused to fit appearance for target modalities acquired with sparse slices. Experiments on the UK Biobank, GBM, and ABCD datasets for through-plane super-resolution across multiple modalities (T2-weighted, FLAIR, DWI, ASL), degradation factors ($\times 3$, $\times 5$, $\times 7$), and pathological abnormalities (glioblastoma) demonstrate state-of-the-art reconstruction fidelity. The shared Gaussian geometry enables arbitrary-view generation for target modalities with strong structural consistency and further shows potential for self-supervised in-plane super-resolution. This work establishes explicit geometry-guided representations as a novel, flexible, and interpretable pathway toward retrospective multi-contrast MRI harmonization and reliable clinical reference construction. Source code is available at: https://github.com/yfgao76/AtlasGS

eess.IV↗

AutoIQ: An Ensemble Framework for Automatic Assessment of Geometric Distortion in Prostate Diffusion-Weighted Imaging

Geometric distortion in prostate diffusion-weighted imaging (DWI) can impair lesion localization and reduce the reliability of MRI-based clinical assessment. We propose AutoIQ, an ensemble machine learning framework for automatic quantification and classification of DWI geometric distortion severity. A total of 140 retrospective prostate biparametric MRI examinations were analyzed, including 33 scans with severe distortion requiring repeat acquisition and 107 scans with acceptable distortion based on expert radiologist assessment. AutoIQ combines two complementary distortion quantification strategies: a segmentation-based method measuring prostate boundary mismatch between T2-weighted imaging (T2WI) and DWI, and a registration-based method estimating deformation magnitude after DWI-to-T2WI alignment. The resulting distortion scores were used to train individual classifiers and a logistic-regression ensemble model. Both computational methods significantly differentiated severe from acceptable distortion cases (p < 0.001). On an independent test set, the ensemble model achieved an accuracy of 0.95, F1-score of 0.93, and AUC of 0.98, outperforming individual models. These results suggest that AutoIQ can provide automated, quantitative quality assessment for prostate DWI and may help identify scans that require repeat acquisition.

eess.IV↗

BCER Agent: Reliable Long-Horizon MRI Workflow Execution via Compilation, Artifact Binding, and Bounded Local Recovery

Many recent medical VLM and agent studies are benchmarked on 2D images or comparatively short tool-calling exchanges, whereas real MRI analysis typically demands long, interdependent pipelines that operate on 3D/4D volumetric data. Under these conditions, reactive tool-calling agents are prone to cascading breakdowns triggered by faulty intermediate references, mismatched tool arguments, and limited control over cross-step dependencies. To address this, we introduce BCER (Brain-Cerebellum-Extremity-Reflector), a controller architecture aimed at dependable long-horizon MRI workflow execution. BCER decouples high-level planning from execution and provides bounded local recovery. We assess BCER on a multi-organ MRI benchmark covering brain, prostate, and cardiac tasks with both short- and long-chain workflows, using matched task contracts across controller variants and several backbone models. Relative to reactive baselines, BCER yields consistent improvements in end-to-end execution, with the most pronounced gains observed on long-chain workflows. BCER additionally enables auditability by maintaining explicit links between final outputs and intermediate artifacts and measurements. Code and benchmark are released at https://github.com/Albertlongzi/BCER.

eess.IV↗

Let Distortion Guide Restoration (DGR): A physics-informed learning framework for Prostate Diffusion MRI

We present Distortion-Guided Restoration (DGR), a physics-informed hybrid CNN-diffusion framework for acquisition-free correction of severe susceptibility-induced distortions in prostate single-shot EPI diffusion-weighted imaging (DWI). DGR is trained to invert a realistic forward distortion model using large-scale paired distorted and undistorted data synthesized from distortion-free prostate DWI and co-registered T2-weighted images from 410 multi-institutional studies, together with 11 measured B0 field maps from metal-implant cases incorporated into a forward simulator to generate low-b DWI (b = 50 s per mm squared), high-b DWI (b = 1400 s per mm squared), and ADC distortions. The network couples a CNN-based geometric correction module with conditional diffusion refinement under T2-weighted anatomical guidance. On a held-out synthetic validation set (n = 34) using ground-truth simulated distortion fields, DGR achieved higher PSNR and lower NMSE than FSL TOPUP and FUGUE. In 34 real clinical studies with severe distortion, including hip prostheses and marked rectal distension, DGR improved geometric fidelity and increased radiologist-rated image quality and diagnostic confidence. Overall, learning the inverse of a physically simulated forward process provides a practical alternative to acquisition-dependent distortion-correction pipelines for prostate DWI.

eess.IV↗