Searcharxiv⌕ Search

arXiv subjects

Zongheng Guo

Publications and source records attributed to Zongheng Guo.

5 recordsLinked to original sources

InterBand-EMG: A Cross-Band Foundation Model for Generalizable Hand-Pose Estimation

Surface electromyography (sEMG) enables continuous hand-pose estimation, but learning representations that generalize across users and movements remains challenging. We introduce InterBand-EMG, which combines band-specific quantization with cross-band reconstruction and structured masked code prediction to learn transferable EMG representations for hand-pose tracking. We also introduce SynapMyo, an eight-channel EMG-to-pose dataset comprising 1,227.74 hand-hours from 499 users across 68 movement categories. Experiments on emg2pose and SynapMyo show that InterBand-EMG outperforms state-of-the-art baselines in joint-angle accuracy across all three generalization settings on both datasets. The source code and the SynapMyo dataset will be publicly released upon acceptance of this paper.

cs.CV↗

Re-JEPA: Coupling Representation Prediction and Signal Reconstruction for State-Conditioned EMG Tracking

Improving continuous hand tracking from surface electromyography (sEMG) requires generalization across users and motion types while maintaining sensitivity to subtle movements. Joint-embedding predictive architectures (JEPAs) learn latent representation spaces through contextual prediction, but their effectiveness for tracking depends on which motion-relevant details these representations preserve and how those details are interpreted as the hand state evolves. We introduce Re-JEPA, a tracking framework that couples representation prediction with signal reconstruction and incorporates state-conditioned motion decoding. During pretraining without kinematic labels, Re-JEPA predicts continuous latent targets at multiple levels from visible EMG patches and reconstructs masked amplitude and phase attributes from the fused predictions. Signal reconstruction imposes an additional constraint on the contextual predictor, encouraging its outputs to retain information needed for signal recovery. For downstream tracking, the Gated Persistent Motion (GPM) decoder conditions EMG-token readout on recurrent state tokens and motion history, then generates continuous trajectories through gated state updates and incremental pose prediction. Under the emg2pose tracking protocol, Re-JEPA reduces angular MAE after full fine-tuning by approximately 10.3%, 19.3%, and 14.9% relative to vemg2pose on the cross-user, cross-stage, and joint cross-user-stage splits, respectively.

cs.RO↗

When Derived Measurements Mislead: Quantifying and Mitigating LLM Over-Trust with Privileged-Modality Reliability Evidence

Derived measurements increasingly enter large language model (LLM) pipelines as direct facts despite their instance-dependent validity. We define derived-feature over-trust (DFOT) as the failure in which a downstream LLM assigns such a measurement the epistemic status of a direct fact or uses it outside its valid scope. Using physiological sensing as a case study, D1 tests acceptance of a PPG-derived rhythm contradicted by offline ECG, whereas D2 tests rejection of an offline-confirmed reliable PPG rhythm under misleading severe history. ECG supplies training supervision and offline reference construction but is never shown to the LLM. Five estimands quantify this chain: conflict over-trust rate (COTR) and context-induced error rate (CIR) characterize D1/D2; correct repair rate (CRR) measures frozen-error repair; evidence-specific repair margin (ESRM) contrasts matched and patient-disjoint shuffled evidence; and utility harm rate (UHR) measures unnecessary verification among HIGH-reliability cases used without verification at baseline. The framework does not depend on a particular reliability generator. We demonstrate it on 50,000 paired PPG-ECG records using ECG-to-PPG privileged distillation as an illustrative baseline and PPG-only inference. On a protocol-locked 187-patient test, the baseline improves four repair and specificity endpoints by 1.82-6.69 percentage points, with all paired confidence intervals excluding zero; UHR increases by 0.67 percentage points (95% CI: -0.4 to +1.7). DFOT provides a common evaluation target for stronger mitigation methods. The code is available at https://github.com/Zongheng-Guo/When-Derived-Measurements-Mislead.

cs.AI↗

SIGMA-PPG: Statistical-prior Informed Generative Masking Architecture for PPG Foundation Model

Current foundation model for photoplethysmography (PPG) signals is challenged by the intrinsic redundancy and noise of the signal. Standard masked modeling often yields trivial solutions while contrastive methods lack morphological precision. To address these limitations, we propose a Statistical-prior Informed Generative Masking Architecture (SIGMA-PPG), a generative foundation model featuring a Prior-Guided Adversarial Masking mechanism, where a reinforcement learning-driven teacher leverages statistical priors to create challenging learning paths that prevent overfitting to noise. We also incorporate a semantic consistency constraint via vector quantization to ensure that physiologically identical waveforms (even those altered by recording artifacts or minor perturbations) map to shared indices. This enhances codebook semantic density and eliminates redundant feature structures. Pre-trained on over 120,000 hours of data, SIGMA-PPG achieves superior average performance compared to five state-of-the-art baselines across 12 diverse downstream tasks. The code is available at https://github.com/ZonghengGuo/SigmaPPG.

cs.LG↗

QualityFM: a Multimodal Physiological Signal Foundation Model with Self-Distillation for Signal Quality Challenges in Critically Ill Patients

Photoplethysmogram (PPG) and electrocardiogram (ECG) are commonly recorded in intesive care unit (ICU) and operating room (OR). However, the high incidence of poor, incomplete, and inconsistent signal quality, can lead to false alarms or diagnostic inaccuracies. The methods explored so far suffer from limited generalizability, reliance on extensive labeled data, and poor cross-task transferability. To overcome these challenges, we introduce QualityFM, a novel multimodal foundation model for these physiological signals, designed to acquire a general-purpose understanding of signal quality. Our model is pre-trained on an large-scale dataset comprising over 21 million 30-second waveforms and 179,757 hours of data. Our approach involves a dual-track architecture that processes paired physiological signals of differing quality, leveraging a self-distillation strategy where an encoder for high-quality signals is used to guide the training of an encoder for low-quality signals. To efficiently handle long sequential signals and capture essential local quasi-periodic patterns, we integrate a windowed sparse attention mechanism within our Transformer-based model. Furthermore, a composite loss function, which combines direct distillation loss on encoder outputs with indirect reconstruction loss based on power and phase spectra, ensures the preservation of frequency-domain characteristics of the signals. We pre-train three models with varying parameter counts (9.6 M to 319 M) and demonstrate their efficacy and practical value through transfer learning on three distinct clinical tasks: false alarm of ventricular tachycardia detection, the identification of atrial fibrillation and the estimation of arterial blood pressure (ABP) from PPG and ECG signals.

cs.LG↗