Searcharxiv⌕ Search

SEARCH · Searcharxiv

Results for “physics.ins-det”

Search indexed arXiv papers on artificial intelligence, large language models, computer vision and robotics. Read source abstracts and follow links to arXiv.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11Linked to original sources

New Dark Matter Detectors using DNA or RNA for Nanometer Tracking

Weakly Interacting Massive Particles (WIMPs) may constitute most of the matter in the Universe. The ability to detect the directionality of recoil nuclei will considerably facilitate detection of WIMPs. In this paper we propose a novel type of dark matter detector: detectors made of DNA or RNA could provide nanometer resolution for tracking, an energy threshold of 0.5 keV, and can operate at room temperature. When a WIMP from the Galactic Halo elastically scatters off of a nucleus in the detector, the recoiling nucleus then traverses hundreds of strings of single stranded nucleic acids (ssNA) with known base sequences and severs ssNA strands along its trajectory. The location of the break can be identified by amplifying and identifying the segments of cut ssNA using techniques well known to biologists. Thus the path of the recoiling nucleus can be tracked to nanometer accuracy. In one such detector concept, the transducers are nanometer-thick Au-foils of 1m x 1m, and the direction of recoiling nuclei is measured by "NA Tracking Chamber" consisting of ordered array of ssNA strands. Polymerase Chain Reaction (PCR) and ssNA sequencing are used to read-out the detector. The proposed detector is smaller and cheaper than other alternatives: 1 kg of gold and 0.1 to 4 kg of ssNA (depending on length and strand density), packed into 0.01m$^3$, can be used to study 10 GeV WIMPs. A variety of other detector target elements could be used in this detector to optimize for different WIMP masses and to identify WIMP properties. By leveraging advances in molecular biology, we aim to achieve about 1,000-fold better spatial resolution than in conventional WIMP detectors at reasonable cost.

astro-ph.IM↗

GPS-based CERN-LNGS time link for Borexino

We describe the design, the equipment, and the calibration of a new GPS based time link between CERN and the Borexino experiment at the Gran Sasso Laboratory in Italy. This system has been installed and operated in Borexino since March 2012, and used for a precise measurement of CNGS muon neutrinos speed in May 2012. The result of the measurement will be reported in a different letter.

physics.ins-det↗

Comparing unloaded Q-factor of a high-Q dielectric resonator measured using the transmission mode and reflection mode methods involving S-parameter circle fitting

A comparative study of unloaded Q-factor measurements of a TE011 mode sapphire dielectric resonator with unloaded Q-factor value of 731,000 at a frequency of 10 GHz and temperature of 65 K using two best Q-factor measurement methods are presented. The Transmission (TMQF) and Reflection methods are based on relevant multi-frequency S-parameter measurements and circle fitting procedures to compute the unloaded Q-factor of the resonator. For accurate comparison of the methods a delay compensation procedure (introduced in the TMQF technique to remove delay due to non-calibrated cables) has been applied also to the reflection data.

physics.ins-det↗

Analysis of the MACRO experiment data to compare particles arrival times under Gran Sasso

The claim of a neutrino velocity different from the speed of the light, made in September 2001 by the Opera experiment, suggested the study of the time delays between TeV underground muons in the Gran Sasso laboratory using the old data of the MACRO experiment, ended in 2000. This study can give also hints on new physics in the particle cascade produced by the interaction of a cosmic ray with the atmosphere.

hep-ex↗

Analysis of Dual-beam Asymmetrical Torsional Bi-Material Cantilever for Temperature Sensing Applications

An extremely sensitive temperature measurement MEMS device is developed based on the principle of structural deflection in a bi-material cantilever caused by a difference in thermal expansion coefficients. A dual-beam asymmetrical geometry is used to produce a torsional response from the device. An analytical model is developed to predict the performance and optimize the free parameters of the device. In this work, it is performed to analyze the flexural and torsional eigenfrequencies as well as confirm the theoretical predictions of DC and AC response. Lastly, a procedure is developed to allow fabrication of the device using equipment available in the Columbia University clean room.

physics.ins-det↗

CLIC e+e- Linear Collider Studies

This document provides input from the CLIC e+e- linear collider studies to the update process of the European Strategy for Particle Physics. It is submitted on behalf of the CLIC/CTF3 collaboration and the CLIC physics and detector study. It describes the exploration of fundamental questions in particle physics at the energy frontier with a future TeV-scale e+e- linear collider based on the Compact Linear Collider (CLIC) two-beam acceleration technique. A high-luminosity high-energy e+e- collider allows for the exploration of Standard Model physics, such as precise measurements of the Higgs, top and gauge sectors, as well as for a multitude of searches for New Physics, either through direct discovery or indirectly, via high-precision observables. Given the current state of knowledge, following the observation of a \sim125 GeV Higgs-like particle at the LHC, and pending further LHC results at 8 TeV and 14 TeV, a linear e+e- collider built and operated in centre-of-mass energy stages from a few-hundred GeV up to a few TeV will be an ideal physics exploration tool, complementing the LHC. Two example scenarios are presented for a CLIC accelerator built in three main stages of 500 GeV, 1.4 (1.5) TeV, and 3 TeV, together with the layout and performance of the experiments and accompanied by cost estimates. The resulting CLIC physics potential and measurement precisions are illustrated through detector simulations under realistic beam conditions.

physics.acc-ph↗

Breadboard model of the LISA phasemeter

An elegant breadboard model of the LISA phasemeter is currently under development by a Danish-German consortium. The breadboard is build in the frame of an ESA technology development activity to demonstrate the feasibility and readiness of the LISA metrology baseline architecture. This article gives an overview about the breadboard design and its components, including the distribution of key functionalities.

astro-ph.IM↗

A transposed frequency technique for phase noise and frequency stability measurements

The digital signal processing has greatly simplified the process of phase noise measurements, especially in oscillators, but its applications are largely confined to the frequencies below 400 MHz. We propose a novel transpose frequency technique, which extends the frequency range of digital noise measurements to the microwave domain and beyond. We discuss two basic variations of the proposed noise measurement technique, one of which enables characterization of phase fluctuations added to the passing signal by the particular microwave component, for example by an amplifier, while another one is intended for measurements of phase fluctuations of the incoming signal itself.

physics.ins-det↗

Practical use of waveguides for polarized neutrons studies

We present the use of planar waveguides to produce neutron microbeams in order to investigate magnetic micro-structures with a micrometric spatial resolution. We report experimental results on such measurements on a polarized neutron reflectometer using a nonmagnetic waveguide structure to probe an amorphous magnetic microwire. The spin-resolved transmission of a neutron microbeam through a microwire was studied. The one dimensional mapping of the neutron precession across the wire was measured.

cond-mat.mes-hall↗

Construction of AC Motor Controllers for NOvA Experiment Upgrades

I have been constructing Alternating Current (AC) motor controllers for manipulation of particle beam detectors. The capability and reliability of these motor controllers are essential to the Laboratory's mission of accurate analysis of the particle beam's position. The device is moved in and out of the beam's path by the motor controller followed by the Neutrinos at the Main Injector Off-Axis νe Appearance (NOvA) Experiment further down the beam pipe. In total, I built and tested ten ac motor controllers for new beam operations in the NOvA experiment. These units will prove to be durable and provide extremely accurate beam placement for NOνA Experiment far into the future.

physics.acc-ph↗

Direct Electron Detection And Imaging Using CCD

The purpose of this project is to investigate the use of charge couple devices (CCDs) to detect electrons directly. This can be done in transmission electron microscopy (TEM) for electrons over 100 KeV, but for space plasma instruments, lower energies are of interest. At the entrance surface of a back illuminated CCD, there is an insensitive layer of oxide and silicon. This layer needs to be kept as thin as possible, in order to detect the electrons of interest, which have short absorption depths. Following analysis of the parameters, we are going to measure the least amount of energy we can detect from electron interaction with the thinned layer. The detection process is simulated by combining two separate models: First: Mulasses, using Geant4, to simulate the interaction of the incident electron with the silicon, giving the energy absorption as a function of depth; Second A model from Stern et al. of the charge collection efficiency as a function of depth. Combining these models gives a measure of the charge collected as a function of incident electron energy, which is the relationship of interest.

physics.ins-det↗

Benchmarking TPB-coated Light Guides for Liquid Argon TPC Light Detection Systems

Scintillation light from liquid argon is produced at 128 nm and thus must be shifted to visible wavelengths in light detection systems used for Liquid Argon Time Projection Chambers (LArTPCs). To date, designs have employed tetraphenyl butadiene (TPB) coatings on photomultiplier tubes (PMTs) or plates placed in front of the PMTs. Recently, a new approach using TPB-coated light guides was proposed. In this paper, we show that the response of lightguides coated with TPB in a UV Transmitting (UVT) acrylic matrix is very similar to that of a coating using a polystyrene (PS) matrix. We obtain a factor of three higher light yield than has been previously reported from lightguides. This paper provides information on the response of the lightguides so that these can be modeled in simulations for future LArTPCs. This paper also identifies areas of R&D for potential improvements in the lightguide response

physics.ins-det↗

Gamma Ray Array Detector Trigger Sub-System

Gamma Ray Array Detector (GRAD) is one of External Target Facility (ETF) subsystems at the Heavy Ion Research Facility at Lanzhou. The trigger subsystem of the GRAD has been developed based on Field Programmable Gate Array (FPGAs) and PXI interface. The GRAD trigger subsystem makes prompt L1 trigger decisions to select valid events. These decisions are made by processing the hit signals from 1024 CsI scintillators of the GRAD. According to the physical requirements, the GRAD trigger subsystem generates 12-bit trigger signals that are passed to the ETF global trigger system. In addition, the GRAD trigger subsystem generates trigger data that are packed and transmitted to the host computer via PXI bus for off-line analysis. The trigger processing is implemented in the front-end electronics and one FPGA of the trigger module. The logic of PXI transmission and reconfiguration is implemented in the other FPGA of the trigger module. The reliable and efficient performance in the Gamma-ray experiments demonstrates that the GRAD trigger subsystem is capable to satisfy the physical requirements.

physics.ins-det↗

A GEM Detector System for an Upgrade of the High-eta Muon Endcap Stations GE1/1 + ME1/1 in CMS

Based on the CMS Upgrade R&D Proposal RD10.02, we describe the motivation and main features of the CMS GEM Project for LS2 and propose the addition of a full GE1/12 detector station comprising Gas Electron Multiplier (GEM) chambers to the forward muon system of CMS. The limitations of the currently existing forward muon detector when operating at increasingly high luminosity expected after LS1 are laid out followed by a brief description of the anticipated performance improvements achievable with a GE1/1 station. The second part describes the detector system followed by an overview of electronics and associated services including a discussion of the schedule and cost of the project. Plans for a precursor demonstrator installation in LS1 are presented. This proposal is intended as a concise follow-up of the detailed document CMS-IN-2012-023. If approved, this is to be followed by a detailed Technical Design Report.

physics.ins-det↗

Theoretical analysis of beta- emission from 63-Ni nano-particles in glassy 15-P

The energy loss of $β^-$ emission emitting from a 63-Ni source in a phosphorus 15-P scintillation medium is theoretically studied. It has shown the $β$ energy spectrum absorption in ${15}P$ had nearly 100% efficiency for $\leq$ 28 keV in 800 μm scintillator thickness. This can eventually lead to the production of light sources using these beta-emitting radiation sources as a low energy source in the near future.

cond-mat.other↗

Recent Results from the ANTARES Neutrino Telescope

The ANTARES underwater neutrino telescope is located in the Mediterranean Sea about 40 km from Toulon at a depth of 2475 m. In its 12 line configuration it has almost 900 photomultipliers in 295 floors. The performance of the detector is discussed and several results are presented, including the measurements of downgoing muons, atmospheric neutrinos, search for a diffuse flux of high energy muon neutrinos, search for cosmic point sources of neutrinos, multi messenger astronomy, searches for fast magnetic monopoles and slow nuclearites. A short discussion is also made on Earth and Sea Science studies with a neutrino telescope.

hep-ex↗

Structural characterization of as-deposited cesium iodide films studied by X-ray diffraction and transmission electron microscopy techniques

In the present work, cesium iodide (CsI) thin films of different thickness have been prepared by thermal evaporation technique. The crystallite size and grain size of these films are compared by using X-ray diffraction (XRD) profile analysis as well as by transmission electron microscopy (TEM) counting, respectively. These two methods provide less deviation between crystallite size and grain size in the case of thin CsI films of 4 nm, but there is comparatively large difference in case of thicker CsI films (20 nm, 100 nm and 500 nm). It indicates that dislocations are arranged in a configuration which causes small orientational difference between two adjacent coherent regions. The size obtained from XRD corresponds to two separate regions, whereas in the TEM micrograph the two regions may seem to correspond one region particularly in case of thicker films. Other physical parameters such as strain, stress and deformation energy density are also estimated precisely for the prominent XRD peaks of thicker CsI films in the range $2θ= 20^{0}-80^{0}$ by using a modified Williamson-Hall (W-H) analysis assuming uniform deformation model (UDM), uniform deformation stress model (UDSM) and uniform deformation energy density model (UDEDM).

cond-mat.mtrl-sci↗

Commissioning of the Testbeam Prototype of the CALICE Tile Hadron Calorimeter

The CALICE collaboration is currently developing an engineering prototype of an analog hadron calorimeter for a future linear collider like the ILC. One main task of this prototype is to demonstrate the feasibility of building a realistic detector with fully integrated front-end electronics. To reach the required high jet energy resolution the detector is based on highly segmented read out layers. The signals are sampled by scintillating tiles that are individually read out by silicon photomultipliers. The readout chips are integrated into the calorimeter layers and are optimized for minimal power consumption. An LED system is integrated into each channel of the detector to calibrate the photodetectors. This report presents the realization of a setup of one layer and the performance in a testbeam environment.

physics.ins-det↗