SearcharxivSearch

arXiv · 0705.0511

Vibration-Induced Conductivity Fluctuation Measurement for Soil Bulk Density Analysis

Abstract

Soil bulk density affects water storage, water and nutrient movement, and plant root activity in the soil profile. Its measurement is difficult in field conditions. Vibration-induced conductivity fluctuation was investigated to quantify soil bulk density with possible field applications in the future. The AC electrical conductivity of soil was measured using a pair of blade-like electrodes while exposing the soil to periodic vibration. The blades were positioned longitudinally and transversally to the direction of the induced vibration to enable the calculation of a normalized index. The normalized index was expected to provide data independent from the vibration strength and to reduce the effect of soil salinity and water content. The experiment was conducted on natural and salinized fine sand at two moisture conditions and four bulk densities. The blade-shaped electrodes improved electrode-soil contact compared to cylindrical electrodes, and thereby, reduced measurement noise. Simulations on a simplified resistor lattice indicate that the transversal effect increases as soil bulk density decreases. Measurement of dry sand showed a negative correlation between the normalized conductivity fluctuation and soil bulk density for both longitudinal and transversal settings. The decrease in the transversal signal was smaller than expected. The wet natural and salinized soils performed very similarly as hypothesized, but their normalized VICOF response was not significant to bulk density changes.

Explore related subjects

Keep this discovery

BibTeXRIS

Andrea Sz. Kishne, Cristine L. S. Morgan, Hung-Chih Chang, Laszlo B. Kish. 2007-05-03. Vibration-Induced Conductivity Fluctuation Measurement for Soil Bulk Density Analysis. https://doi.org/10.1117/12.724667

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det