SearcharxivSearch

arXiv · 1007.1572

A SQUID based read-out of sub-attoNewton force sensor operating at millikelvin temperatures

Abstract

An increasing number of experiments require the use of ultrasensitive nanomechanical resonators. Relevant examples are the investigation of quantum effects in mechanical systems [1] or the detection of exceedingly small forces as in Magnetic Resonance Force Microscopy (MRFM) [2]. The force sensitivity of a mechanical resonator is typically limited by thermal fluctuations, which calls for detection methods capable of operating at ultralow temperature. Commonly used interferometric techniques, despite their excellent sensitivity, may not be an optimal choice at millikelvin temperatures, because of unwanted resonator heating caused by photon absorption. Although alternative detection techniques based on microwave cavities [3] [4] [5] have shown to perform better at ultralow temperature, these techniques still suffer from the fact that the detection sensitivity decreases as the power input is decreased. Here, we present a measurement approach based on the detection, through a Superconducting Quantum Interference Device (SQUID), of the change of magnetic flux induced in a coil by the motion of a magnetic particle attached to a resonator. This detection scheme avoids direct heating of the resonator, as it does not involve reflecting optical or microwave photons to the resonator. By cooling an ultrasoft silicon resonator to 25 mK, we achieve a force noise of 0.5 aN in a 1 Hz bandwidth. We believe this detection technique can in principle be used even at sub-millikelvin temperatures. Furthermore, it could be used to improve the sensitivity of MRFM experiments, which aim at three dimensional imaging at atomic resolution.

Explore related subjects

Keep this discovery

BibTeXRIS

O. Usenko, A. Vinante, G. Wijts, T. H. Oosterkamp. 2010-07-09. A SQUID based read-out of sub-attoNewton force sensor operating at millikelvin temperatures. https://arxiv.org/abs/1007.1572

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det