A Primer on Computational Simulation in Congenital Heart Disease for the Clinician

Abstract

Interest in the application of engineering methods to problems in congenital heart disease has gained increased popularity over the past decade. The use of computational simulation to examine common clinical problems including single ventricle physiology and the associated surgical approaches, the effects of pacemaker implantation on vascular occlusion, or delineation of the biomechanical effects of implanted medical devices is now routinely appearing in clinical journals within all pediatric cardiovascular subspecialties. In practice, such collaboration can only work if both communities understand each other's methods and their limitations. This paper is intended to facilitate this communication by presenting in the context of congenital heart disease (CHD) the main steps involved in performing computational simulation-from the selection of an appropriate clinical question/problem to understanding the computational results, and all of the "black boxes" in between. We examine the current state of the art and areas in need of continued development. For example, medical image-based model-building software has been developed based on numerous different methods. However, none of them can be used to construct a model with a simple "click of a button". The creation of a faithful, representative anatomic model, especially in pediatric subjects, often requires skilled manual intervention. In addition, information from a second imaging modality is often required to facilitate this process. We describe the technical aspects of model building, provide a definition of some of the most commonly used terms and techniques (e.g. meshes, mesh convergence, Navier-Stokes equations, and boundary conditions), and the assumptions used in running the simulations. Particular attention is paid to the assignment of boundary conditions as this point is of critical importance in the current areas of research within the realm of congenital heart disease. Finally, examples are provided demonstrating how computer simulations can provide an opportunity to "acquire" data currently unobtainable by other modalities, with essentially no risk to patients. To illustrate these points, novel simulation examples of virtual Fontan conversion (from preoperative data to predicted postoperative state) and outcomes of different surgical designs are presented. The need for validation of the currently employed techniques and predicted results are required and the methods remain in their infancy. While the daily application of these technologies to patient-specific clinical scenarios likely remains years away, the ever increasing interest in this area among both clinicians and engineers makes its eventual use far more likely than ever before and, some could argue, only a matter of [computing] time.

Explore related subjects

Keep this discovery

BibTeXRIS

Irene Vignon Clementel, Alison L. Marsden, Jeffrey A. Feinstein. 2010-12-06. A Primer on Computational Simulation in Congenital Heart Disease for the Clinician. https://doi.org/10.1016/j.ppedcard.2010.09.002

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Phase-contrast micro-CT for intra-operative breast tumour margin assessment using a microfocus x-ray source and photon-counting detector

Objective: Intra-operative tumour margin assessment during breast-conserving surgery requires rapid, high-resolution imaging of excised tissue, allowing the surgical team to take appropriate action within a single operation. This study evaluates a custom propagation-based phase-contrast micro-computed tomography (micro-CT) system designed to meet these clinical constraints without specialised optical elements. Methods: The experimental setup pairs a microfocus x-ray source with a photon-counting detector in a cone-beam geometry. We explore how the spatial coherence of the source can provide propagation-based phase contrast -- with no additional specialised optical elements -- and balance this against maximising the x-ray flux of the cone-beam geometry. System performance was evaluated across two anode target materials and filtration configurations at various tube power settings. Imaging capabilities were validated using anthropomorphic breast tissue phantoms and a formalin-fixed paraffin-embedded (FFPE) breast tissue specimen, with reconstructions compared against gold-standard histology. Results: An unfiltered tungsten target operated at 40 kVp yielded optimal image quality. The optimised system achieved high-resolution CT reconstructions of a 5 cm diameter sample with an isotropic voxel size of 40.7 $\upmu\text{m}$ in a scan time of 12 minutes. Reconstructed volumes demonstrated strong visual correlation with corresponding histology slides. Conclusion: Combining a microfocus source with a photon-counting detector enables high-resolution, phase-contrast micro-CT within a clinically viable timeframe, demonstrating strong potential for intra-operative margin assessment.

physics.med-ph

Understanding Search and Decision Errors in Liver Metastasis Detection and the Effects of Lower Radiation Dose

The detection performance of liver metastases decreases with the reduction of radiation dose, but misses are heterogeneous. Previous eye tracking work has characterized missed metastases into two categories: search errors i.e., the eyes never land on the lesion, and decision errors i.e., the lesion is seen but not recognized as malignant. We integrated three prior reader studies to answer this question. In all studies, radiologists interpreted the same set of 40 contrast enhanced abdominal CT exams containing 91 liver metastases whose locations had been previously marked. In two studies, the workstation recorded their gaze and eye movements. Using eye dwell times, metastases were classified as search-error-dominant (majority of misses had <2 sec gaze time) or decision-error-dominant (>2 sec gaze time). In the third study, exams were interpreted both at 120 and 200 quality reference mAs (QRM) by ten radiologists. The third study did not include eye tracking. Out of 91 liver metastases, we excluded 16 that were never missed in the eye tracking studies and used 75 liver metastases for the present study.

physics.med-ph

Develop and Optimize 5DCT Imaging Simulation and Reconstruction Methods

Purpose: To develop and optimize a 5DCT (3D + cardiac phase + respiratory phase) imaging simulation and reconstruction pipeline, and to compare two sinogram-space interpolation methods for reconstructing images at arbitrary combinations of cardiac and respiratory phase. Methods: Helical CT projections were simulated from the 4D XCAT phantom across a range of cardiac and respiratory motion states, with Poisson and electronic noise added. Ground-truth-matched volumes were generated at 5 cardiac phases and 10 respiratory amplitudes (50 total phase combinations). Because acquired projections are sparsely and unevenly distributed across this joint phase space, each target slice was reconstructed by interpolating rebinned sinogram rows to the target cardiac phase and respiratory amplitude, using either 2D scattered barycentric interpolation or 2D scattered local linear interpolation with a circular kernel for cardiac phase. Reconstructed volumes were compared to phantom ground truth using mean absolute error (MAE), and to conventional respiratory-gated 4DCT (r4DCT) reconstructed from the same simulated data. Results: Both interpolation methods eliminated the severe axial misalignment artifacts present when helical projections were reconstructed without phase-space interpolation. Local linear interpolation achieved lower MAE than barycentric interpolation across most tested conditions, with the largest improvement at low pitch. The 5DCT pipeline also produced respiratory-only volumes with fewer residual cardiac-motion artifacts than conventional r4DCT reconstructed from the same projection data, including at standard clinical pitch (0.1). Conclusions: 5DCT reconstruction using sinogram-space interpolation is feasible and can jointly resolve cardiac and respiratory motion with better accuracy than conventional 4DCT reconstruction.

physics.med-ph