A large HPGe detector for the non-destructive radioassay of an ultra-low-background counting facility
Abstract
We present the use of a low background counting facility, equipped with a p-type 80% relative efficiency HPGe detector, protected by active and passive shielding, and large enough to count a 10" photo-multiplier tube (PMT). A GEANT4 Monte-Carlo of this detector was developed and tuned to 3% accuracy. We report the U, Th, and K contents in three different types of PMTs used in current neutrino experiments, with accuracies of $\sim 10$ ppb for U and Th and of $\sim 15$ ppm for K.
Explore related subjects
Keep this discovery
M. Fechner, C. Henson, J. Gaffiot, T. Lasserre, A. Letourneau, D. Lhuillier, G. Mention, Th. A. Mueller, R. Quéval, R. Svoboda. 2011-01-20. A large HPGe detector for the non-destructive radioassay of an ultra-low-background counting facility. https://arxiv.org/abs/1101.4000