SearcharxivSearch

arXiv · 1112.0435

Characterization of escape times of Josephson Junctions for signal detection

Abstract

The measurement of the escape time of a Josephson junction might be used to detect the presence of a sinusoidal signal embedded in noise when standard signal processing tools can be prohibitive. We show that the prescriptions for the experimental set-up and some physical behaviors depend on the detection strategy. More specifically, by exploiting the sample mean of escape times to perform detection, two resonant regions are identified. At low frequencies there is a stochastic resonance/activation phenomenon, while near the plasma frequency a geometric resonance appears. The naive sample mean detector is outperformed, in terms of error probability, by the optimal likelihood ratio test. The latter exhibits only geometric resonance, showing monotonically increasing performance as the bias current approaches the junction critical current. In this regime the escape times are vanishingly small and therefore performance are essentially limited by measurement electronics. The behavior of the likelihood ratio and sample mean detector for different values of incoming signal to noise ratio are discussed, and a relationship with the error probability is found. The likelihood ratio test based detectors could be employed also to estimate unknown parameters in the applied input signal. As a prototypical example we study the phase estimation problem of a sinusoidal current, that is accomplished by using the filter bank approach. Finally we show that for a physically feasible detector the performances are found to be very close to the Cramer- Rao theoretical bound. Applications might be found for example in some astronomical detection problems or to analyze weak signals in the sub-terahertz range.

Explore related subjects

Keep this discovery

BibTeXRIS

Paolo Addesso, Giovanni Filatrella, Vincenzo Pierro. 2011-12-02. Characterization of escape times of Josephson Junctions for signal detection. https://doi.org/10.1103/physreve.85.016708

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det