SearcharxivSearch

arXiv · 1205.4494

A 490 GHz planar circuit balanced Nb-Al$_\mathbf{2}$O$_{\mathbf{3}}$-Nb quasiparticle mixer for radio astronomy: Application to quantitative local oscillator noise determination

Abstract

This article presents a heterodyne experiment which uses a 380-520 GHz planar circuit balanced Nb-$\mathrm{Al_2O_3}$-Nb superconductor-insulator-superconductor (SIS) quasiparticle mixer with 4-8 GHz instantaneous intermediate frequency (IF) bandwidth to quantitatively determine local oscillator (LO) noise. A balanced mixer is a unique tool to separate noise at the mixer's LO port from other noise sources. This is not possible in single-ended mixers. The antisymmetric IV characteristic of a SIS mixer further helps to simplify the measurements. The double-sideband receiver sensitivity of the balanced mixer is 2-4 times the quantum noise limit $h\nu/k_B$ over the measured frequencies with a maximum LO noise rejection of 15 dB. This work presents independent measurements with three different LO sources that produce the reference frequency but also an amount of near-carrier noise power which is quantified in the experiment as a function of the LO and IF frequency in terms of an equivalent noise temperature $T_{LO}$. In a second experiment we use only one of two SIS mixers of the balanced mixer chip, in order to verify the influence of near-carrier LO noise power on a single-ended heterodyne mixer measurement. We find an IF frequency dependence of near-carrier LO noise power. The frequency-resolved IF noise temperature slope is flat or slightly negative for the single-ended mixer. This is in contrast to the IF slope of the balanced mixer itself which is positive due to the expected IF roll-off of the mixer. This indicates a higher noise level closer to the LO's carrier frequency. Our findings imply that near-carrier LO noise has the largest impact on the sensitivity of a receiver system which uses mixers with a low IF band, for example superconducting hot-electron bolometer (HEB) mixers.

Explore related subjects

Keep this discovery

BibTeXRIS

M. P. Westig, M. Justen, K. Jacobs, J. Stutzki, M. Schultz, F. Schomacker, C. E. Honingh. 2012-05-21. A 490 GHz planar circuit balanced Nb-Al$_\mathbf{2}$O$_{\mathbf{3}}$-Nb quasiparticle mixer for radio astronomy: Application to quantitative local oscillator noise determination. https://doi.org/10.1063/1.4764324

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det