arXiv · 1208.6147
Calculation of thermal parameters of SiGe microbolometers
Abstract
The thermal parameters of a SiGe microbolometer were calculated using numerical modeling. The calculated thermal conduction and thermal response time are in good agreement with the values found experimentally and range between 2x10$^-7$ and 7x10$^-8$ W/K and 1.5 and 4.5 ms, respectively. High sensitivity of microbolometer is achieved due to optimization of the thermal response time and thermal conduction by fitting the geometry of supporting heat-removing legs or by selection of a suitable material providing boundary thermal resistance higher than 8x10$^-3$ cm$^2$K/W at the SiGe interface.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
A. V. Voitsekhovskii, D. V. Grigoryev, V. A. Yuryev, S. N. Nesmelov. 2012-08-30. Calculation of thermal parameters of SiGe microbolometers. https://doi.org/10.1007/s11182-008-9015-4