arXiv · 1210.3220
Annealing-induced magnetic moments detected by spin precession measurements in epitaxial graphene on SiC
Abstract
We present results of non-local and three terminal (3T) spin precession measurements on spin injection devices fabricated on epitaxial graphene on SiC. The measurements were performed before and after an annealing step at 150 degrees Celsius for 15 minutes in vacuum. The values of spin relaxation length L_s and spin relaxation time tau_s obtained after annealing are reduced by a factor 2 and 4, respectively, compared to those before annealing. An apparent discrepancy between spin diffusion constant D_s and charge diffusion constant D_c can be resolved by investigating the temperature dependence of the g-factor, which is consistent with a model for paramagnetic magnetic moments.
Explore related subjects
Keep this discovery
Bastian Birkner, Daniel Pachniowski, Andreas Sandner, Markus Ostler, Thomas Seyller, Jaroslav Fabian, Mariusz Ciorga, Dieter Weiss, Jonathan Eroms. 2013-02-25. Annealing-induced magnetic moments detected by spin precession measurements in epitaxial graphene on SiC. https://doi.org/10.1103/physrevb.87.081405
Cite the original work for its findings. Save a collection to share your selection of sources.