arXiv · 1305.6881
A non-invasive electron thermometer based on charge sensing of a quantum dot
Abstract
We present a thermometry scheme to extract the temperature of a 2DEG by monitoring the charge occupation of a weakly tunnel-coupled 'thermometer' quantum dot using a quantum point contact detector. Electronic temperatures between 97 mK and 307 mK are measured by this method with an accuracy of up to 3 mK, and agree with those obtained by measuring transport through a quantum dot. The thermometer does not pass a current through the 2DEG, and can be incorporated as an add-on to measure the temperature simultaneously with another operating device. Further, the tuning is independent of temperature.
Explore related subjects
Keep this discovery
A. Mavalankar, S. J. Chorley, J. Griffiths, G. A. C. Jones, I. Farrer, D. A. Ritchie, C. G. Smith. 2013-05-29. A non-invasive electron thermometer based on charge sensing of a quantum dot. https://doi.org/10.1063/1.4823703