Study of X-ray radiation damage in the AGIPD sensor for the European XFEL

Abstract

The European X-ray Free Electron Laser (XFEL), currently being constructed in Hamburg and planning to be operational in 2017 for users, will deliver 27,000 fully coherent, high brilliance X-ray pulses per second with duration less than 100 fs. The unique features of the X-ray beam pose major challenges for detectors used at the European XFEL for imaging experiments, in particular a radiation tolerance of silicon sensors for doses up to 1 GGy for 3 years of operation at an operating voltage above 500 V. One of the detectors under development at the European XFEL is the Adaptive Gain Integrating Pixel Detector (AGIPD), which is a hybrid detector system with ASICs bump-bonded to p+n silicon pixel sensors. We have designed the silicon sensors for the AGIPD, which have been fabricated by SINTEF and delivered in the beginning of February of 2013. To demonstrate the performance of the AGIPD sensor with regard to radiation hardness, mini-sensors with the same pixel and guard-ring designs as the AGIPD together with test structures have been irradiated at the beamline P11 of PETRA III with 8 keV and 12 keV monoenergetic X-rays to dose values up to 10 MGy. The radiation hardness of the AGIPD sensor has been proven and all electrical properties are within specification before and after irradiation. In addition, the oxide-charge density and surface-current density from test structures have been characterized as function of the X-ray dose and compared to previous measurements for test structures produced by four vendors.

Explore related subjects

Keep this discovery

BibTeXRIS

Jiaguo Zhang, Eckhart Fretwurst, Heinz Graafsma, Robert Klanner, Ioannis Kopsalis, Joern Schwandt. 2013-12-13. Study of X-ray radiation damage in the AGIPD sensor for the European XFEL. https://doi.org/10.1088/1748-0221%2F9%2F05%2Fc05022

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det