arXiv · 1402.3129
Design and First Tests of a Radiation-Hard Pixel Sensor for the European X-Ray Free-Electron Laser
Abstract
The high intensity and high repetition rate of the European X-ray Free-Electron Laser, presently under construction in Hamburg, requires silicon sensors which can stand X-ray doses of up to 1 GGy for 3 years of operation at high bias voltage. Within the AGIPD Collaboration the X-ray-radiation damage in MOS Capacitors and Gate-Controlled Diodes fabricated by four vendors on high-ohmic n-type silicon with two crystal orientations and dif- ferent technological parameters, has been studied for doses between 1 kGy and 1 GGy. The extracted values of oxide-charge and surface-current densi- ties have been used in TCAD simulations, and the layout and technological parameters of the AGIPD pixel sensor optimized. It is found that the op- timized layout for high X-ray doses is significantly different from the one for non-irradiated sensors. First sensors and test structures have been de-livered in early 2013. Measurement results for X-ray doses of 0 to 10 MGy and their comparison to simulations are presented. They demonstrate that the optimization has been successful and that the sensors fulfill the required specifications.
Explore related subjects
Keep this discovery
Joern Schwandt, Eckhart Fretwurst, Robert Klanner, Ioannis Kopsalis, Jiaguo Zhang. 2014-02-13. Design and First Tests of a Radiation-Hard Pixel Sensor for the European X-Ray Free-Electron Laser. https://doi.org/10.1109/tns.2014.2304239
Cite the original work for its findings. Save a collection to share your selection of sources.