arXiv · 1405.5442
Thermo-elastic induced phase noise in the LISA Pathfinder spacecraft
Abstract
During the On-Station Thermal Test campaign of the LISA Pathfinder the data and diagnostics subsystem was tested in nearly space conditions for the first time after integration in the satellite. The results showed the compliance of the temperature measurement system, obtaining temperature noise around $10^{-4}\,{\rm K}\, {\rm Hz}^{-1/2}$ in the frequency band of $1-30\;{\rm mHz}$. In addition, controlled injection of heat signals to the suspension struts anchoring the LISA Technology Package (LTP) Core Assembly to the satellite structure allowed to experimentally estimate for the first time the phase noise contribution through thermo-elastic distortion of the LTP interferometer, the satellite's main instrument. Such contribution was found to be at $10^{-12}\,{\rm m}\, {\rm Hz}^{-1/2}$, a factor of 30 below the measured noise at the lower end of the measurement bandwidth ($1\,{\rm mHz}$).
Explore related subjects
Keep this discovery
Ferran Gibert, Miquel Nofrarias, Nikolaos Karnesis, Lluís Gesa, Víctor Martín, Ignacio Mateos, Alberto Lobo, Reinhold Flatscher, Domenico Gerardi, Johannes Burkhardt, Ruediger Gerndt, David Robertson, Henry Ward, Paul William McNamara, Felipe Guzmán, Martin Hewitson, Ingo Diepholz, Jens Reiche, Gerhard Heinzel, Karsten Danzmann. 2014-05-19. Thermo-elastic induced phase noise in the LISA Pathfinder spacecraft. https://doi.org/10.1088/0264-9381%2F32%2F4%2F045014
Cite the original work for its findings. Save a collection to share your selection of sources.