arXiv · 1408.3720
RPC Gap Production and Performance for CMS RE4 Upgrade
Abstract
CMS experiment constructed the fourth Resistive Plate Chamber (RPC) trigger station composed of 144 RPCs to enhance the high momentum muon trigger efficiency at both endcap regions. All new CMS endcap RPC gaps are produced in accordance with QA and QC at the Korea Detector Laboratory (KODEL) in Korea. All qualified gaps have been delivered to three assembly sites: CERN in Switzerland, BARC in India, and Ghent University in Belgium for the RPC detector assembly. In this paper, we present the detailed procedures used in the production of RPC gaps adopted for the CMS upgrade.
Explore related subjects
Keep this discovery
Sung Keun Park, Min Ho Kang, Kyong Sei Lee. 2014-08-16. RPC Gap Production and Performance for CMS RE4 Upgrade. https://doi.org/10.1088/1748-0221/9/11/c11009