Fundamental limitations to high-precision tests of the universality of free fall by dropping atoms

Abstract

Tests of the universality of free fall and the weak equivalence principle probe the foundations of General Relativity. Evidence of a violation may lead to the discovery of a new force. The best torsion balance experiments have ruled it out to 10^-13. Cold-atom drop tests have reached 10^-7 and promise to do 7 to 10 orders of magnitude better, on the ground or in space. They are limited by the random shot noise, which depends on the number N of atoms in the clouds. As mass-dropping experiments in the non-uniform gravitational field of Earth, they are sensitive to the initial conditions. Random accelerations due to initial condition errors of the clouds are designed to be at the same level as shot noise, so that they can be reduced with the number of drops along with it. This sets the requirements for the initial position and velocity spreads of the clouds with given N. In the STE-QUEST space mission proposal aiming at 2x10^-15 they must be about a factor 8 above Heisenberg's principle limit, and the integration time required to reduce both errors is 3 years, with a mission duration of 5 years. Instead, offset errors at release between different atom clouds are systematic and give rise to a systematic effect which mimics a violation. Such offsets must be demonstrated to be as small as required in all drops, must be small by design and must be measured. For STE-QUEST to meet its goal they must be several orders of magnitude smaller than the size of each individual cloud, which in its turn must be at most 8 times larger than the uncertainty principle limit. Even if all technical problems are solved and the clouds are released with negligible systematic errors, still they must be measured. Then, Heisenberg's principle dictates that the measurement lasts as long as the experiment and the systematic nature of the effect requires many measurements for it to be ruled out as a source of violation.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Anna M. Nobili. 2016-01-25. Fundamental limitations to high-precision tests of the universality of free fall by dropping atoms. https://doi.org/10.1103/physreva.93.023617

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Kinematic Fitting of electromagnetic calorimeter data - an improved method

Kinematic fitting is widely used in particle physics experiments as a powerful tool to improve experimental resolutions, to suppress background and to provide selection criteria for the identification of specific reactions. Kinematic fitting methods, however, typically assume that the fitted quantities follow Gaussian distributions; an assumption which does not always hold. This is particularly true for energy measurements from electromagnetic calorimeters. This issue can largely be overcome by performing a transformation of the non-Gaussian variables into variables which follow a Gaussian distribution. The new adapted kinematic fitting procedure allows to better account for the non-Gaussian nature of the measured calorimeter energies, at the same time improving the accuracy and robustness of the kinematic fit. This leads to improved pull and confidence-level distributions of the kinematic fit as well as improved invariant mass distributions and signal-to-background ratios in the final event sample.

physics.ins-det

Radiation hardness characterization of SiPM sensors for Low Earth Orbit space missions

This work presents a comprehensive radiation hardness characterization of SiPM devices for space-based applications: FBK NUV-HD-MT and NUV-HD-LowCT (1$\times$1, 3$\times$3, and 6$\times$6~mm$^2$) and Hamamatsu S14160 MPPCs with equivalent active areas. Total Ionizing Dose (TID) tests were performed at the ESA/ESTEC Co-60 facility with a level of dose up to 20~krad in silicon, while displacement damage effects were evaluated using 100~MeV protons with a fluence up to $1.12\times10^{11}$~p/cm$^2$ at the Paul Scherrer Institute. Radiation damage in SiPMs manifests through two main mechanisms: ionizing energy loss and non-ionizing energy loss (NIEL), which increases dark current and dark count rate. In this work, breakdown voltage, dark current, and quenching resistance were systematically measured as functions of accumulated dose and fluence. Gain and dark count rates were indirectly measured from the characterized electrical parameters. Both technologies exhibit remarkable stability of most of the functional parameters across all dose levels, while dark current shows predictable increases significantly more pronounced under proton irradiation due to displacement damage. Based on these results, both FBK and Hamamatsu devices are confirmed suitable for Low Earth Orbit (LEO) mission environment.

physics.ins-det

Characterization of immersed SiPM arrays in liquid scintillator between room temperature and $-30\,^{\circ}\mathrm{C}$

Liquid scintillator detectors instrumented with distributed silicon photomultiplier (SiPM) arrays can be used in compact, topology-sensitive, and low-background experiments, but the temperature dependence of SiPMs immersed directly in the scintillation medium has not been widely characterized. We report the operation of a 125-liter linear-alkylbenzene-based liquid scintillator detector read out by 125 SiPM channels immersed in the active volume, over the range from room temperature to $-30\,^{\circ}\mathrm{C}$. The detector response was measured with cosmic-ray muons, including stopping muons followed by their Michel-electron decay. Cooling from $+15\,^{\circ}\mathrm{C}$ to $-30\,^{\circ}\mathrm{C}$ reduced the SiPM dark-count rate by a factor of 13.5, increased the single-photoelectron response by 49.1%, and increased the cosmic-ray muon light yield by 16.7%. The improved photoelectron separation and baseline stability at low temperature enabled a selection of stopping-muon events, from which the effective muon lifetime was measured to be $1959\pm132\,\mathrm{ns}$, consistent with the value expected for a hydrocarbon scintillator once $μ^{-}$ capture on carbon is taken into account.

physics.ins-det