arXiv · 1506.06851
Application of the First Collision Source Method to CSNS Target Station Shielding Calculation
Abstract
Ray effects are the inherent problem of discrete ordinates method. RAY3D, a functional module of ARES which is a discrete ordinates code system, employs a semi-analytic first collision source method to mitigate ray effects. This method decomposes the flux into uncollided and collided components, and then calculates them with analytical method and discrete ordinates method respectively. In this article, RAY3D is validated by the Kobayashi benchmarks and applied to the neutron beamline shielding problem of China Spallation Neutron Source (CSNS) target station. Numerical results of the Kobayashi benchmarks indicate that DONTRAN3D with RAY3D solutions agree well with the Monte Carlo solutions. The dose rate at the end of the neutron beamline is less than 10.83 μSv/h in CSNS target station neutron beamline shutter model. RAY3D can effectively mitigate ray effects and obtain relatively reasonable results.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Ying Zheng, Bin Zhang, Meng-Teng Chen, Liang Zhang, Yi-Xue Chen, Wen Yin, Tian-Jiao Liang. 2015-06-23. Application of the First Collision Source Method to CSNS Target Station Shielding Calculation. https://doi.org/10.1088/1674-1137%2F40%2F4%2F046201
Cite the original work for its findings. Save a collection to share your selection of sources.