Lumped element kinetic inductance detectors maturity for space-borne instruments in the range between 80 and 180 GHz
Abstract
This work intends to give the state-of-the-art of our knowledge of the performance of LEKIDs at millimetre wavelengths (from 80 to 180~GHz). We evaluate their optical sensitivity under typical background conditions and their interaction with ionising particles. Two LEKID arrays, originally designed for ground-based applications and composed of a few hundred pixels each, operate at a central frequency of 100, and 150~GHz ($\Delta \nu / \nu$ about 0.3). Their sensitivities have been characterised in the laboratory using a dedicated closed-circle 100~mK dilution cryostat and a sky simulator, allowing for the reproduction of realistic, space-like observation conditions. The impact of cosmic rays has been evaluated by exposing the LEKID arrays to alpha particles ($^{241}$Am) and X sources ($^{109}$Cd) with a readout sampling frequency similar to the ones used for Planck HFI (about 200~Hz), and also with a high resolution sampling level (up to 2~MHz) in order to better characterise and interpret the observed glitches. In parallel, we have developed an analytical model to rescale the results to what would be observed by such a LEKID array at the second Lagrangian point.
Explore related subjects
Keep this discovery
A. Catalano, A. Benoit, O. Bourrion, M. Calvo, G. Coiffard, A. D'Addabbo, J. Goupy, H. Le Sueur, J. Macìas-Pérez, A. Monfardini. 2015-11-09. Lumped element kinetic inductance detectors maturity for space-borne instruments in the range between 80 and 180 GHz. https://doi.org/10.1051/0004-6361%2F201527715
Cite the original work for its findings. Save a collection to share your selection of sources.