arXiv · 1604.02650
Alignment and characterization of the two-stage time delay compensating XUV monochromator
Abstract
We present the design, implementation and alignment procedure for a two-stage time delay compensating monochromator. The setup spectrally filters the radiation of a high-order harmonic generation source providing wavelength-selected XUV pulses with a bandwidth of 300 to 600~meV in the photon energy range of 3 to 50~eV. XUV pulses as short as $12\pm3$~fs are demonstrated. Transmission of the 400~nm (3.1~eV) light facilitates precise alignment of the monochromator. This alignment strategy together with the stable mechanical design of the motorized beamline components enables us to automatically scan the XUV photon energ in pump-probe experiments that require XUV beam pointing stability. The performance of the beamline is demonstrated by the generation of IR-assisted sidebands in XUV photoionization of argon atoms.
Explore related subjects
Keep this discovery
Martin Eckstein, Johan Hummert, Markus Kubin, Chung-Hsin Yang, Fabio Frassetto, Luca Poletto, Marc J. J. Vrakking, Oleg Kornilov. 2016-04-10. Alignment and characterization of the two-stage time delay compensating XUV monochromator. https://arxiv.org/abs/1604.02650
Cite the original work for its findings. Save a collection to share your selection of sources.