SearcharxivSearch

arXiv · 1606.00929

Neutron lifetime measurements and effective spectral cleaning with an ultracold neutron trap using a vertical Halbach octupole permanent magnet array

Abstract

Ultracold neutron (UCN) storage measurements were made in a trap constructed from a 1.3 T Halbach Octupole PErmanent (HOPE) magnet array aligned vertically, using the TES-port of the PF2 source at the Institut Laue-Langevin. A mechanical UCN valve at the bottom of the trap was used for filling and emptying. This valve was covered with Fomblin grease to induce non-specular reflections and was used in combination with a movable polyethylene UCN remover inserted from the top for cleaning of above-threshold UCNs. Loss due to UCN depolarization was suppressed with a minimum 2 mT bias field. Without using the UCN remover, a total storage time constant of $(712 \pm 19)$ s was observed; with the remover inserted for 80 s and used at either 80 cm or 65 cm from the bottom of the trap, time constants of $(824 \pm 32)$ s and $(835 \pm 36)$ s were observed. Combining the latter two values, a neutron lifetime of $τ_{\rm n} = (887 \pm 39)$ s is extracted after primarily correcting for losses at the UCN valve. The time constants of the UCN population during cleaning were observed and compared to calculations based on UCN kinetic theory as well as Monte-Carlo studies. These calculations are used to predict above-threshold populations of $\sim 5\%$, $\sim 0.5\%$ and $\sim 10^{-12}\%$ remaining after cleaning in the no remover, 80~cm remover and 65~cm remover measurements. Thus, by using a non-specular reflector covering the entire bottom of the trap and a remover at the top of the trap, we have established an effective cleaning procedure for removing a major systematic effect in high-precision $τ_{\rm n}$ experiments with magnetically stored UCNs.

Explore related subjects

Keep this discovery

BibTeXRIS

K. K. H. Leung, P. Geltenbort, S. Ivanov, F. Rosenau, O. Zimmer. 2016-06-02. Neutron lifetime measurements and effective spectral cleaning with an ultracold neutron trap using a vertical Halbach octupole permanent magnet array. https://doi.org/10.1103/physrevc.94.045502

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Reinvestigation of the Yield of the Trinity Device

Previous published analyses of trinitite to determine the yield of the Trinity nuclear explosion used various estimates of the fraction of fission products that became incorporated in trinitite. Furthermore, these studies utilized nuclear data that has subsequently been revised. Utilizing a planar germanium detector, we observed gamma rays produced by the decays of both 137Cs and 239Pu from four samples of trinitite. From the observed 137Cs/239Pu ratios of and a simple analysis method based on current nuclear data and weapons debris studies, we find an average yield of 9.1+-4.5 kilotons from our four samples. While this result is substantially lower than the established total yield of 21 kilotons, it is in reasonable agreement that attributable to fissions in the 239Pu core alone.

nucl-ex

Search for neutrinoless quadruple beta decay of $^{136}$Xe in PandaX-4T detector

The observation of neutrinoless quadruple beta decay (0$\nu$4$\beta$) in the absence of neutrinoless double beta decay (0$\nu$2$\beta$) has been argued to provide a strong indication that neutrinos are Dirac particles. We report a search for 0$\nu$4$\beta$ decay of $^{136}\text{Xe}$ using a total $^{136}\text{Xe}$ exposure of 148.4 kg$\cdot$yr, collected during the commissioning and the first science runs of the PandaX-4T experiment. No significant excess of events over the background is observed. A lower limit on the 0$\nu$4$\beta$ decay half-life of $^{136}\text{Xe}$ is set at 6.01 x $10^{24}$ yr at the 90% confidence level. This result establishes the most stringent constraint on this process in xenon, demonstrating the unique capability of the PandaX-4T detector in probing lepton number violation and shedding light on the fundamental nature of neutrinos.

nucl-ex

Island of Inversion in neutron-rich cobalt isotopes revealed from mass measurements

Mass measurements of the ground and isomeric states of $^{68-70}$Co have been performed using the JYFLTRAP Penning-trap mass spectrometer at the IGISOL facility. The masses were measured, either for the first time for the isomeric states of $^{68}$Co and $^{70}$Co, or with greatly improved precision for the others, removing ambiguities in the mass surface beyond $N=40$. The ordering of the low and high-spin states in $^{68}$Co and $^{70}$Co has also been established. The results, supported by Large-Scale Shell Model and Discrete Non-Orthogonal Shell-Model calculations, show a gradual lowering of intruder states with increasing neutron number, eventually leading to an inversion in $^{70}$Co. These findings clarify previously proposed contradictory interpretations. Finally, we demonstrate the importance of including induced effective 3N forces for a consistent description of binding energies in the island of inversion near $N=40$.

nucl-ex