SearcharxivSearch

arXiv · 1609.03783

Commissioning of the COBRA demonstrator and investigation of surface events as its main background

Abstract

The COBRA collaboration investigates 0{\nu}\beta\beta-decays (neutrinoless double beta-decays). Therefore, a demonstrator setup using coplanar-grid CdZnTe detectors is operated at the LNGS underground laboratory. In this work, the demonstrator was commissioned and completed, which is discussed extensively. The demonstrator works reliably and collects low-background physics data. One result of the analysis of the data is that surface events are the dominating background component. To better understand and possibly discriminate this background, surface events were studied in detail. This was done mainly using laboratory measurements. For a better interpretation of these measurements, simulations of particle trajectories and ranges were done. The surface sensitivity tests showed large differences between the individual detectors. Often, a dead-layer was determined, especially at the surfaces where the non-collecting anode (NCA) is the outermost anode rail. Due to this, the sensitivity of the surfaces where the collecting anode (CA) is adjacent was typically about a factor of three larger than the NCA sensitivity. A comparison of the pulse shape analysis methods LSE and A/E was done. Laboratory measurements indicate, that the latter performs better. Alpha scanning measurements were done to spatially investigate the surface sensitivity. Plausible variations were measured. However, no hints were found how to improve the surface event recognition. The instrumentation of the guard ring, which surrounds the anode structure, was tested and improved the surface event discrimination significantly. The fraction of surviving alpha events was at a per-mill level. Important steps for a future large-scale COBRA experiment are discussed briefly, mainly the use of an integrated read-out system. Overall, the results indicate a large potential in background reduction for the COBRA experiment.

Explore related subjects

Keep this discovery

BibTeXRIS

Jan Tebrügge. 2016-09-13. Commissioning of the COBRA demonstrator and investigation of surface events as its main background. https://arxiv.org/abs/1609.03783

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det