SearcharxivSearch

arXiv · 1609.05447

Implementation of A Nanosecond Time-resolved APD Detector System for NRS Experiment in HEPS-TF

Abstract

A nanosecond time-resolved APD detector system is implemented for Nuclear Resonance Scattering (NRS) experiments in High Energy Photon Source-Test Facility (HEPS-TF) project of China. The detector system consists of three parts: the APD sensors, the fast preamplifiers and the TDC readout electronics. To improve the reception solid angle and the quantum efficiency, the C30703FH APDs (fabricated by Excelitas) are used as the sensors of the detectors. The C30703FH has an effective light-sensitive area of 10X10 mm2 and an absorption layer thickness of 110 {\mu}m. The fast preamplifier with gain of 59 dB and bandwidth of 2 GHz is designed to readout the weak signal outputted by the C30703FH APD. The detector system can work in single photon measurement mode because the preamplifier increases the signal-to-noise ratio. Moreover, the TDC is realized by FPGA multiphase method with a resolution bin of 1ns. The arrival time of all scattering events between two start triggers can be recorded by the FPGA TDC. In the X-ray energy of 14.4 keV, the time resolution (FWHM) of the developed detector (APD sensor + fast amplifier) is 0.86 ns, and the whole detector system (APD sensors + fast amplifiers + TDC readout electronics) achieves a time resolution of 1.4 ns.

Explore related subjects

Keep this discovery

BibTeXRIS

Zhen-jie Li, Yi-chao Ma, Qiu-ju Li, Peng Liu, Jin-fan Chang, Yang-fan Zhou. 2016-09-18. Implementation of A Nanosecond Time-resolved APD Detector System for NRS Experiment in HEPS-TF. https://arxiv.org/abs/1609.05447

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det