Study of linearity of LYSO crystal for HERD calorimeter
Abstract
The High Energy cosmic Radiation Detection (HERD) facility is a space mission designed for detecting cosmic ray (CR) electrons, $\gamma$-rays up to tens of TeV and CR nuclei from proton to iron up to several PeV. The main instrument of HERD is a 3-D imaging calorimeter (CALO) composed of nearly ten thousand cubic LYSO crystals. A large dynamic range of single HERD CALO Cell (HCC) is necessary to achieve HERD's PeV observation objectives, which means that the response of HCC should maintain a good linearity from minimum ionizing particle (MIP) calibration to PeV shower maximum. In order to study the linearity of HCC over such a large energy range, a beam test has been implemented at the E2 and E3 beam lines of BEPC. High intensity pulsed electron beam provided by E2 line are used for producing high energy density within HCC; $\pi^{+}$/proton provided by E3 line are used for HCC calibration. The results show that no saturation effect occurs and the linearity of HCC is better than 10% from 30 MeV (1 MIP) to 1.1$\times$10$^{3}$ TeV (energy density is 93 TeV/cm$^{3}$), which can meet the requirement mentioned above.
Explore related subjects
Keep this discovery
Zheng Quan, Zhi-gang Wang, Ming Xu, Yong-wei Dong, Jun-jing Wang, Guang-peng An, Xin Liu, Tian-wei Bao, Li Zhang, Rui-jie Wang, Jun-guang Lv, Bo-bing Wu, Shuang-nan Zhang. 2016-11-28. Study of linearity of LYSO crystal for HERD calorimeter. https://arxiv.org/abs/1611.09128