SearcharxivSearch

arXiv · 1704.01456

Heat spreader with parallel microchannel configurations employing nanofluids for near active cooling of MEMS

Abstract

While parallel microchannel based cooling systems have been around for quite a period of time, employing the same and incorporating them for near active cooling of microelectronic devices is yet to be implemented and the implications of the same on thermal mitigation to be understood. The present article focusses on a specific design of the PMCS such that it can be implemented at ease on the heat spreader of a modern microprocessor to obtain near active cooling. Extensive experimental and numerical studies have been carried out to comprehend the same and three different flow configurations of PMCS have been adopted for the present investigations. Additional to focussing on the thermofluidics due to flow configuration, nanofluids have also been employed to achieve the desired essentials of mitigation of overshoot temperatures and improving uniformity of cooling. Two modelling methods, Discrete Phase Modelling and Effective Property Modelling have been employed for numerical study to model nanofluids as working fluid in micro flow paths and the DPM predictions have been observed to match accurately with experiments. To quantify the thermal performance of PMCS, an appropriate Figure of Merit has been proposed. From the FoM It has been perceived that the Z configuration employing nanofluid is the best suitable solutions for uniform thermal loads to achieve uniform cooling as well as reducing maximum temperature produced with in the device. The present results are very promising and viable approach for futuristic thermal mitigation of microprocessor systems.

Explore related subjects

Keep this discovery

BibTeXRIS

Lakshmi Sirisha Maganti, Purbarun Dhar, T Sundararajan, Sarit Kumar Das. 2017-02-27. Heat spreader with parallel microchannel configurations employing nanofluids for near active cooling of MEMS. https://arxiv.org/abs/1704.01456

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det